background image

APMC4110 User’s Manual                                                   Standalone PMC Carrier 

__________________________________________________________________ 

________________________________________________________________________

 

Acromag, Inc.  Tel:248-624-1541  Fax:248-624-9234  Email:[email protected]  http://www.acromag.com 

 

IMPORTANT SAFETY CONSIDERATIONS 

You must consider the possible negative effects of power, wiring, 
component, sensor, or software failure in the design of any type of  
control or monitoring system.  This is very important where property 
loss or human life is involved.  It is important that you perform 
satisfactory overall system design and it is agreed between you and 
Acromag, that this is your responsibility. 

 

 
 

1.0  GENERAL INFORMATION 

3

 

1.1  FIELD I/O CONNECTORS 

3

 

1.2  POWER 

6

 

1.3  MANUAL RESET 

6

 

1.4  XILINX JTAG PORT 

6

 

 

2.0  PREPARATION FOR USE 

8

 

2.1  UNPACKING AND INSPECTION 

8

 

2.2  INSTALLATION CONSIDERATIONS 

8

 

2.3  NON-ISOLATION CONSIDERATIONS 

8

 

 

3.0  SERVICE AND REPAIR ASSISTANCE 

9

 

3.1  PRELIMINARY SERVICE PROCEDURE 

9

 

3.2  WHERE TO GET HELP 

9

 

 

4.0 SPECIFICATIONS 

10

 

4.1  PHYSICAL 

10

 

4.2  ENVIRONMENTAL 

10

 

4.3  POWER REQUIREMENTS 

10

 

 

CERTIFICATE OF VOLATILITY 

11

 

 

Trademarks are the property of their respective owners. 

TABLE OF 
CONTENTS 

The information of this manual 
may change without notice.  
Acromag makes no warranty 
of any kind with regard to this 
material, including, but not 
limited to, the implied 
warranties of merchantability 
and fitness for a particular 
purpose.  Further, Acromag 
assumes no responsibility for 
any errors that may appear in 
this manual and makes no 
commitment to update, or 
keep current, the information 
contained in this manual.  No 
part of this manual may be 
copied or reproduced in any 
form without the prior written 
consent of Acromag, Inc. 

Summary of Contents for APMC4110

Page 1: ...rutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In sto...

Page 2: ...ULE USER S MANUAL ACROMAG INCORPORATED Tel 248 295 0310 30765 South Wixom Road Fax 248 624 9234 P O BOX 437 Wixom MI 48393 7037 U S A Copyright 2010 Acromag Inc Printed in the USA Data and specificati...

Page 3: ...ESET 6 1 4 XILINX JTAG PORT 6 2 0 PREPARATION FOR USE 8 2 1 UNPACKING AND INSPECTION 8 2 2 INSTALLATION CONSIDERATIONS 8 2 3 NON ISOLATION CONSIDERATIONS 8 3 0 SERVICE AND REPAIR ASSISTANCE 9 3 1 PREL...

Page 4: ...ONNECTORS The PMC module s connections are made to the Acromag APMC4110 carrier field I O connections through the P1 and P2 50 pin connectors The connections are terminated as defined within the PCI s...

Page 5: ...Ch4 10 16 Differential Ch5 11 17 Differential Ch5 12 18 COMMON 19 COMMON 20 Differential Ch6 13 21 Differential Ch6 14 22 COMMON 23 COMMON 24 Differential Ch7 15 25 Differential Ch7 16 26 Differential...

Page 6: ...ial Ch12 26 16 Differential Ch13 27 17 Differential Ch13 28 18 COMMON 19 COMMON 20 Differential Ch14 29 21 Differential Ch14 30 22 COMMON 23 COMMON 24 Differential Ch15 31 25 Differential Ch15 32 26 D...

Page 7: ...0 0 5A Max 3 12 VDC 10 0 5A Max 4 5 VDC 5 6 0A Max Table 1 3 APMC4110 Power Connections The 4 pin male connector shown below mates with the 4 pin female header P3 on the board 5 VDC 12 VDC 12 VDC COMM...

Page 8: ..._____________________ ________________________________________________________________________ Acromag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 7 Figure 1...

Page 9: ...board is physically protected with packing material and electrically protected with an anti static bag during shipment However it is recommended that the board be visually inspected for evidence of mi...

Page 10: ...ervice Policy Bulletin or contact Acromag for complete details on how to obtain parts and repair 3 1 PRELIMINARY SERVICE PROCEDURE Before beginning repair be sure that all of the procedures in Section...

Page 11: ...male receptacle headers P3 4 pin power header P4 14 pin Xilinx JTAG port 4 2 ENVIRONMENTAL Operating Temperature 40 o C to 85 o C Relative Humidity 5 95 Non Condensing Storage Temperature 55 C to 120...

Page 12: ...uct contain Volatile memory i e Memory of whose contents are lost when power is removed Yes No Type SRAM SDRAM etc Size User Modifiable Yes No Function Process to Sanitize Type SRAM SDRAM etc Size Use...

Page 13: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: