INDUSTRIAL I/O PACK COMPLIANCE
Specification.............................….This device meets or exceeds
all written Industrial I/O Pack
specifications per ANSI/VITA 4
1995 for 8MHz and 32MHz
operation with a maximum of
four IP modules. Supports
Type I and Type II ID space
formats.
Mechanical Interface……………...Carrier supports five single-
(For APC8640) size IP modules (A-E), or two
double-size and one single
size IP module. 32-bit IP
modules are not supported.
Electrical Interface………………...Carrier drivers use 3.3V CMOS
logic. The carrier may not be
compatible with IP module
inputs that require 5V CMOS
switching thresholds.
IP Clocks…………………..……….Support 8MHZ (default) or
32MHz IP clocks that are
independently selected per
each IP slot.
I/O Space..............................…….16-bit and 8-bit:
Supports 128 byte values per
IP module.
ID Space...............................…….16 and 8-bit; Supports Type 1
32 bytes per IP (consecutive
odd byte addresses). Also
supports Type II 32 words per
IP via D16 data transfers.
Memory Space......................……16 and 8-bit: Supports up to 8M
bytes per IP. Disabled/enabled
via a jumper (J1).
Interrupts...............................……Supports two interrupt requests
per IP and interrupt
acknowledge cycles via
access to IP INT space.
ENVIRONMENTAL
Operating Temperature................0 to +70
°
C
Relative Humidity.........................5-95% non-condensing
Storage Temperature...................-55 to +125
°
C.
Non-Isolated...........................…..PCI bus and IP module logic
commons have a direct
electrical connection. As such,
unless the IP module provides
isolation between the logic and
field side, the field I/O signals
are not isolated from the PCI
bus.
Radiated Field Immunity (RFI)...... Complies with EN61000-4-3
(3V/m, 80 to 1000MHz and
1.4GHz to 2.0GHz, 1V/m,
2.0GHz to 2.7GHz.) and
European Norm EN50082-1 with
no register upsets.
Conducted RF Immunity (CRFI)….Complies with EN61000-4-6
3V/rms, 150KHz to 80MHz) and
European Norm EN50082-1
with no register upsets.
Electromagnetic Interference
Immunity (EMI)…..............…........No digital upset under the
influence of EMI from
switching solenoids,
commutator motors, and drill
motors.
Electrostatic Discharge
Immunity (ESD)…..............…...... Complies with EN61000-4-2
Level 3 (8KV enclosure port air
discharge) and Level 2 (4KV
enclosure port contact
discharge) and European Norm
EN50082-1.
Surge Immunity……………………Not required for signal I/O per
European Norm EN50082-1.
Electric Fast Transient
Immunity EFT..………………...... Complies with EN61000-4-4
Level 2 (0.5KV at field I/O
terminals) and European Norm
EN50082-1.
Radiated Emissions………..…… Meets or exceeds European
Norm EN50081-1 for class B
equipment. Shielded cable with
I/O connections in shielded
enclosure are required to meet
compliance.