SERIES AP440 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 40 - http://www.acromag.com
- 40 -
www.acromag.com
6.0 SPECIFICATIONS
6.1 Physical
Height:
12.5 mm (0.4921 in)
Height defines Carrier to Module Maximum component height
Board Thickness
1.0 mm (0.03937 in)
AcroPack L x W: 70 mm x 30.00 mm
(2.76 in x 1.18 in)
Unit Weight (does not include shipping material):
AcroPack 0.314ounces (8.9g)
6.2 Power Requirements
6.3 Environmental Considerations
6.3.1 Operating Temperature
Model Number
Description
Temp Range
AP440-1E-LF
4V to
18V DC or AC peak
-40
o
C to 85
o
C
1,2
AP440-2E-LF
16V to
40V DC or AC peak
-40
o
C to 85
o
C
1,2
AP440-3E-LF
38V to
60V DC or AC peak
-40
o
C to 85
o
C
1,2
Note 1: An air cooled application with an AcroPack module will
require a minimum airflow of 200LFM.
Note 2: Applications requiring operating temperatures of 70
o
C to
85
o
C will require purchase of AcroPack Heatsink Accessory AP-CC-
01.
Summarized below are the expected current draws for each of the specified
power supply voltages.
Power Supply Voltage Current Draw
3.3 VDC +/- 5%
1
0.48 A Typical, 0.63 A maximum
1.5 VDC +/- 5%
1
Not Used
5.0 VDC +/- 5%
1
0.048 A Typical, 0.052 A maximum
+12 VDC +/- 5%
1
Not Used
-12 VDC +/- 5%
1
Not Used
Note 1
: Typical current draw is using an AP440-1E-LF
Summarized below are the operating temperature range, airflow
and other environmental requirements and applicable standards for
the AcroPack module.