ACEX4041 COM Express Type 10
AcroPack Carrier Board
- 48 -
Vibration and Shock Standard
The ACEX4041 is designed to pass the following Vibration and Shock standards.
Vibration, Sinusoidal Operating
... Designed to comply with IEC 60068-2-6: 10-500Hz, 5G, 2 Hours/axis
Vibration, Random Operating
...... Designed to comply with IEC 60068-2-64: 10-500Hz, 5G-rms, 2 Hours/axis
Shock, Operating
........................... Designed to comply with IEC 60068-2-27: 30G, 11ms half sine, 50G, 3mS half
sine, 18 shocks at 6 orientations for both test levels
Reliability Prediction
MTBF (Mean Time Between Failure):
MTBF in hours using MIL-HDBK-217F, FN2.
Per MIL-HDBK-217, Ground
Benign, Controlled, G
B
G
C
Temperature
MTBF (Hours)
MTBF (Years)
Failure Rate (FIT
1
)
25°C
290,815
33.2
3,438.6
40°C
210,114
24
4759.3
1
FIT is Failures in 10
9
hours.