Series 570LX-701-C1-10 SmartPack User's Manual Dual Process Current Output
___________________________________________________________________________________________
- 3 -
LED Indicators:
Power LED (Green):
Indicates power applied to unit.
Service LED (Red):
LED blinks at a 1/2 Hz rate for an
unconfigured node. LED OFF for a properly functioning
node. LED ON for failed node.
Status LED (Yellow):
(See Figure 1) LED remains ON
indefinitely upon receiving an "off-line" network management
command. LED remains OFF upon receiving an "on-line"
network management command (normal operation). LED
blinks at a 2.5Hz rate for 10 seconds upon receiving a "wink"
network command. LED flashes quickly three times every
second to indicate a fault condition as defined by the
nvo_wd_status[ x ] and nvo_comp_fault[ x ] variables.
Figure 1: Status LED Behavior
1.
Off-line/On-line Commands
:
Indefinite
ON
OFF
Off-line Command On-line Command
2.
Wink Command:
10 Seconds
ON
OFF
200 200
mS mS
3.
Fault Sequence:
Continues Until
1 Second Fault Removed
ON
OFF
60 60
mS mS
Accuracy:
Better than
±
0.05% of calibrated span, typical. This
error includes the combined effects of module repeatability,
hysteresis, terminal point linearity, and adjustment resolution.
Analog Resolution:
5.87 uA, or 1 part in 2730 (0.037% of 16.0
mA output span).
Ambient Temperature Range:
L1 (44 nodes): -13
°
F to +185
°
F
(-25
°
C to +85
°
C), L1 (64 nodes): +32
°
F to +158
°
F (0
°
C to
70
°
C), L3 (64 nodes): -13
°
F to +185
°
F (-25
°
C to +85
°
C).
Ambient Temperature Effect:
Less than
±
0.003% of output
span per oF (
±
0.005% per oC) over the ambient temperature
range for reference test conditions. Specification includes
the combined effects of zero and span over temperature.
Response Time:
For a network variable update, the output
reaches 98% of output span in 250mS, typical.
Noise Rejection:
Common Mode: Better than 100dB at 60 Hz, typical.
Normal Mode: Not applicable.
RFI Resistance:
Less than
±
0.5% of input span with RFI field
strengths of up to 10V/meter at frequencies of 27MHz,
151MHz, and 467MHz.
EMI Resistance:
Less than
±
0.25% of input span effect with
switching solenoids or commutator motors.
Surge Withstand Capability (SWC):
Input/Output termination's
rated per ANSI/IEEE C37.90-1978. Unit is tested to a
standardized test waveform that is representative of surges
(high frequency transient electrical interference), observed in
actual installations.
Mounting:
General Purpose plastic Housing with integrated
DIN-Rail Mount. Supports "G" & "T" rails: "G" Rail (32mm),
Type EN50035; "T" Rail (35mm), Type EN50022. Refer to
Drawing 4501-327 for outline and clearance dimensions.
Shipping Weight: 1 pound (0.45 Kg) packed.
Construction:
Circuit Boards: Military grade FR-4 epoxy glass circuit
boards.
Circuit Board Coating: Fungus resistant acrylic conformal
coat on analog output circuit board only.
Terminals: Compression type, wire size 14 AWG maximum.
Mounting Position: Position insensitive.
Case: Self-extinguishing NYLON Type 6.6 polyamide
thermoplastic UL94 V-2, color black. General Purpose,
NEMA Type 1 enclosure.
CERTIFICATION:
Consult the factory for current information on
the availability of agency (e.g. Canadian Standards
Association, Factory Mutual, etc.) approvals.
-NCR:
No Certification Required.
INSTALLATION:
The module is packaged in a general purpose enclosure
type. Use an auxiliary enclosure to protect against unfavorable
environments and locations. Maximum operating ambient
temperatures should be within 32 to 158oF (0 to 70oC) for
satisfactory performance. The module is factory calibrated and
ready for installation. Connect as shown in Connection Drawing
4501-333.
Mounting
: Mount the module assembly - refer to Drawing
4501-327 for mounting and clearance dimensions.
DIN Rail Mounting:
Use suitable fastening hardware to
secure the DIN rail to the designated mounting surface. A
module, can be mounted to either the "T" or "G" Rail.
Installation of the module to the rail depends on the type of
DIN rail used (see Drawing 4501-327). Units can be mounted
side-by-side on 1.6 inch centers, if required.
"T" Rail (35mm), Type EN50022: To attach a module to this
style of DIN rail, angle the top of the unit towards the rail and
locate the top groove of the adapter over the upper lip of the
rail. Firmly push the unit towards the rail until it snaps solidly
into place. To remove a module, insert a screwdriver into the
lower arm of the connector and pull downward while applying
outward pressure to the bottom of the unit.