Solis Specifications
*** Please note that Building Regulations Document J advises that additional permanent air supply is
required for appliances with an output of above 5Kw.
With modern properties additional air may be required as Document J suggests that adequate air
would be a benefit.
• If design air permeability
*
5.0m³/ (h.m²) then 550mm²/kW of appliance rated output above 5kW
Or
• If design air permeability
)
5.0m³/ (h.m²) then 550mm²/kW of appliance rated output
• If in doubt, please consult your registered installer for advice.
If installing into a room containing an extractor fan, please ensure that the relevant tests are
carried out according to Document J of the building regulations.
480
480
1004
Nominal heat output
5 kW - Wood
5 kW - Maxibrite
Chimney draft required
12Pa
Height
1004 mm
Width
480 mm
Depth
480 mm
Weight
110 kg
Air Requirement
N/A ***
Flue Mass Gas Flow
5.7 g/s - Wood
3.1 g/s - Maxibrite
CO @ 13% O
2
0.09 Wood vol %
0.06 Maxibrite vol%
Mean Flue Gas Temperature
205°C - Wood
254°C - Maxibrite
Efficiency
82% - Wood
80.9% - Maxibrite
Mean CnHm @13%O2
Wood - 18Nmg/M3
Maxibrite - 9Nmg/M3
Mean NOx @13%O2
Wood -139Nmg/M3
Maxibrite - 98Nmg/M3
DIN Plus Dust @13%O2
Wood -18Nmg/M3
Maxibrite -9Nmg/M3
Log Length
Up To 400 mm