![ACR STOVES Neo 1C-ECO Technical Manual Download Page 17](http://html1.mh-extra.com/html/acr-stoves/neo-1c-eco/neo-1c-eco_technical-manual_2841014017.webp)
17
Re-fueling
When re-fuelling the stove
always refuel
onto a bed of hot embers
, fully open the
air control wheel until the new fuel is well
alight, before adjusting the air control for
the desired setting.
If there is insufficient burning material in
the firebed to light a new fuel charge,
excessive smoke emission can occur.
Refuelling must be carried out onto a
sufficient quantity of glowing embers and
ash that the new fuel charge will ignite in a
reasonable period. If there are too few
embers in the fire bed, add suitable
kindling to prevent excessive smoke.
Fuel overloading
Never overload the stove - it will work very
well with two medium sized logs. The
amount of fuel specified in this manual
should not be exceeded, overloading can
cause excess smoke and may cause
products of combustion to spill into the
room.
Stove slumbering
The Neo-Eco range of stoves has been
designed and tested as an intermittent
wood burning appliance.
Under no circumstances should this
appliance be operated as a slumber style
of stove or for continuous overnight
burning.
This may cause damage to the appliance
and cause excess smoke and pollutants to
enter the atmosphere.
Glass
Never operate the appliance if the glass
panel is broken or cracked. This can cause
the appliance to overfire, which may
damage the appliance and flue system
and may cause a danger to persons and
property. Only use once the glass is
replaced and the sealing gaskets checked
for integrity. Only replace with a
manufacturers approved glass.
Operation with door left open
Operation with the door open can cause
excess smoke and overfiring of the
appliance. The appliance must not be
operated with the appliance door left open
except as directed in the instructions.
Dampers left open
Operation with the air controls or
appliance dampers open can cause
excess heat within the appliance. The
appliance must not be operated with air
controls, appliance dampers or door left
open except as directed in the
instructions.
Never leave the stove unattended
until the new fuel is well alight.
Persistent fume emission is
dangerous and must be
investigated
.
If fume emission persists, open doors and
windows to ventilate the room and let the
fire die out. Have the chimney inspected
for blockages and clean if required. Do not
relight the fire until the cause has been
found. We recommend that you seek
professional advice.
This appliance has been designed to be
burned with the door closed at all times
other than when refuelling.
It should not be operated as an open fire.
Typical refuelling intervals for wood is 1
hour.
NEO ECO range manual 0620-6 25/06/2020 11:18 Page 17