14. Procedure to correct continuous rotation of the light.
14-1 Use the following tools
・
Phillips head screw driver
・
4mm Hexagonal wrench
14-2 Procedure
1) Turn off the power source
2) Remove the search light and place upside down on a suitable surface.
3)
Loosen and remove 8 screws as indicated in picture
49
. Carefully lift the bottom cover off the base.
Picture
49
4) Remove all cables where connected to the printed circuit board.
Remove the bottom cover.
(Refer to picture
50
)
Picture
50