3. Method to check PCB PP-207A (Lamp does not turn on)
3-1 Use the following tools
・
Hexagonal wrench of 4mm
・
DC Multimeter.
3-2 Procedure
1) Remove the search light and place upside down.
2) Loosen and remove 8 screws as indicated in picture 6.
Carefully lift the bottom cover off the base
.
Picture
6
3) Remove 2 cable connectors (P and N) as indicated inside circle in picture
7
.
Picture
7
4) Turn on the power source by pushing the power button on remote control panel. Measure on
terminals P (+) and N (-)with the DC Multimeter for 24V output.
(Refer to picture 7)