Y1-03-0199 Rev. C
10
3.
ZIF Connection and Data Transfer Cable Installation
Data is stored in the memory capsule using the data transfer cable which connects to the junction box on the
bracket, runs thru the cutter mechanism and attaches to the left side of the memory capsule. This cable is
connected to both the junction box and the memory capsule using ZIF (Zero Insertion Force) connectors.
NOTE: ZIF connectors are fragile. To avoid breaking the connectors, touch them carefully. Do not
apply too much pressure to the movable part of the connector when opening or closing it.
To connect the data transfer cable to a ZIF connector, follow these steps:
1. Using your thumb and index finder, pull down on the movable part of the ZIF connector open.
2. Orient the end of the cable with the ZIF connector, and insert the blank side (or printed side) of the cable into
the connector.
3. While holding the cable firmly in place, close the ZIF connector. To ensure a firm connection, make sure the
ZIF connector is completely closed.
To disconnect the data transfer cable from a ZIF connector, follow these steps:
1. Using your thumb and index finder, pull down on the movable part of the ZIF connector open.
2. Pull up gently on the movable part of the connector until the cable is released.
3. Grasp the cable and pull it out of the connector.
4.
Data Transfer Cable Window Installation
After the flex data cable is connected to bracket and memory capsule, the protective window must be installed.
The protective window caps come with pre-lubricated O-ring assembled on the window cap ensures a tight,
waterproof fit.
Step 1
Step 2
Step 3
ZIF Connection Install
Figure 7
TOP
BOTTOM