background image

Y1-03-0241C

  

16 

6. Changing ownership or contact information 

As  the  owner  of  the  beacon,  it  is  your  responsibility  to  advise  the  national 
authority  of  any  change  in  your  registration  information.  If  you  are 
transferring  the  beacon  to  a  new  owner,  you  are  required  to  inform  the 
national  authority.  You  can  do  this  by  using  their  online  database  or  by 
letter, fax or telephone and informing the authority of the name and address 
of the new owner. 
 
The  new  owner  of  the  beacon  is  required  to  provide  the  national 
authority  with  all  of  the  information  requested  on  the  registration  form. 
This  obligation  transfers  to  all  subsequent  owners.  See  earlier  section, 
STEP ONE, for further details on this process. 

7. Lost or stolen PLBs 

If your PLB is lost or stolen, do the following immediately: 

//  Report to your local authorities that the PLB has been lost or stolen 
//  Contact  NOAA  at  (888)  212-7283  (212-SAVE),  or  your  national 
authority, with the following information: 

o

 

Police department name 

o

 

Police department phone number 

o

 

Police case number  

If  your  PLB  were  to  be  activated,  the  information  you  provided  will  be 
forwarded  to  the  appropriate  search  and  rescue  authorities  who  will 
ensure that your PLB gets back to you. If someone attempts to register 
a PLB reported as stolen, NOAA or your national authority will notify the 
appropriate police department.  

 

 

 

Summary of Contents for AquaLink 2883

Page 1: ...Y1 03 0241C i...

Page 2: ...rt ACR Products www acrelectronics com designs and manufactures a complete line of safety and survival products including EPIRBs PLBs AIS SARTs Strobe Lights Life Jacket Lights Search Lights and safet...

Page 3: ...HNICAL SPECIFICATIONS____________________ 20 APPENDIX D WARRANTY USEFUL LIFE POLICY NOTICES________ 21 NOTE re Applicable products This manual supports all configurations of PLB 350B beacons In additi...

Page 4: ...ermine which country s database will have your registration information SAR forces will have information as to who you are as the owner of the beacon the name and type of vessel that you have if appli...

Page 5: ...also acceptable Fax the registration form to the fax number on the top of the registration form NOTE Do not confuse the registration form with the ACR Electronics warranty card 3 If online or fax reg...

Page 6: ...ngs help 406 MHz beacons are a type of portable emergency equipment that transmits a distress signal to search and rescue SAR organizations The purpose of these beacons is to aid SAR teams in tracking...

Page 7: ...ition system The PLB 350 is fitted with an internal GPS receiver that will determine the coordinates latitude and longitude of the beacon s position on the globe to be transmitted to the Cospas Sarsat...

Page 8: ...abel Applied at the factory the 15 character hexadecimal number is unique to each beacon Activation button cover Battery expiration label with the month year the battery needs to be replaced Keypad Mu...

Page 9: ...uoyant Yes No Included Accessories Attachment Clip Multi Function Belt Clip Optional Accessories Flotation pouch ACR P N 9504 5 Activating your beacon Overview Personal Locator Beacons are designed to...

Page 10: ...n its own this likely means it has accidentally been activated and needs to be shut off and reported as a false alert see section on false alerts Activation diagram When activated Red LED transmitting...

Page 11: ...re 3 If at all possible be sure the antenna is positioned facing the sky and avoid submerging in water This device is intended to operate on or above the ground or while attached to your person above...

Page 12: ...if possible Water will shield and inhibit the GPS receiver and may cause difficulties obtaining your GPS coordinates Avoid leaning over the beacon to view blinking LED as you may shield the GPS recept...

Page 13: ...he transmission within a few minutes of beacon activation NOTE If you report a false alert and the authorities have not received the signal do not be concerned This may mean that you were able to deac...

Page 14: ...ement includes servicing the beacon by replacing all o rings testing the water seal and the electrical properties NOTE There are no user serviceable items inside the beacon DO NOT OPEN THE BEACON Open...

Page 15: ...memory 406 MHz synthesizer RF power battery GPS header if equipped If a red LED flashes at the completion of the Self test your beacon has failed Repeat the Self test If the failure persists contact A...

Page 16: ...LAT and longitude LON position This test must be performed outside with a clear view of the sky Press the Self test button for greater than 5 seconds Observe the beacon for the entire GPS test A beep...

Page 17: ...ation form This obligation transfers to all subsequent owners See earlier section STEP ONE for further details on this process 7 Lost or stolen PLBs If your PLB is lost or stolen do the following imme...

Page 18: ...sengage the clip from the beacon The belt clip has been designed to accommodate your extreme adventures You can secure your beacon directly to backpack webbing straps life jackets or belts to ensure t...

Page 19: ...hat you have a strap on your life jacket in the shoulder area for attachment of the PLB The beacon should hang with the GPS receiver up so that the beacon is inverted This will give the GPS receiver t...

Page 20: ...ination Center RCC The RCC dispatches Search and Rescue SAR forces The addition of the GEOSAR satellite system greatly improves the reaction time for a SAR event This satellite system has no Doppler c...

Page 21: ...vironmental Minimum Battery Operating Life 24 hours minimum 4 F to 131 F 20 C to 55 C Battery Replacement Interval Battery replacement due no later than 6 years from date of manufacture 5 years from d...

Page 22: ...rs for the following products EPIRB PLB S VDR SSAS Useful Life Policy The typical service life of a properly maintained Product is limited to 12 years from date of manufacture Products that are 12 yea...

Page 23: ...Walton on Thames Surrey KT12 2TD United Kingdom Certificate No NC 14342 Regulations and ETSI EN 302 152 1 V1 1 1 2003 11 IEC 60945 2002 Standards EN 301 843 1 V1 2 1 2004 06 EN 60950 1 2001 EN 301 48...