background image

SAFETY INFORMATION

WARNING

Always make sure the pump is unplugged as soon as the water level reaches 1/4 in.. At water levels 
less than 1/4 in., the pump is attempting to pump air, which will cause the pump to overheat and wear
out. Running the pump without sufficient water will damage the pump and void the pump's warranty.

Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in 
the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can 
cause an explosion or fire, resulting in property damage, serious personal injury and/or death.

Always disconnect the pump from its power source before inspection.
Do not stand in water when the pump is connected. Do not handle pump with wet hands.
Do not touch the pump housing while it is operating, as the pump may be HOT and can cause
serious skin burns.
Do not disassemble the motor housing. This pump has NO repairable internal parts, and 
disassembling may cause an oil leak or dangerous electrical wiring issues

CAUTION

This submersible utility pump is designed for portable applications. It can drain or remove water
from the following: pits, sinks, window wells, basements, swimming pool covers, boats, low 
spots in yards, or other flooded areas. This pump has not been tested or approved for use in 
swimming pools or in salt-water marine areas.

ADDITIONAL SAFETY PRECAUTIONS

Know the pump applications, limitations, and potential hazards.

 

1.

This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free 
service for many years when properly installed, maintained, and used. However, inadequate 
electrical power to the pump, or blockage by ice, dirt, or debris may cause the pump to fail, 
potentially bringing about additional water damage. To minimize the potential for water damage
 due to pump failure, please read the section of this manual regarding common pump problems 
and remedies or call 800-201-1360

This pump is not designed to function as a permanently installed sump pump. It is also not 
engineered to be run continuously as a “fountain” or “waterfall” pump. Because this pump has 
an oil-filled motor, it should NOT be used in water containing fish. The pump should be used with 
a 5/8 in. or larger inside diameter garden hose, or use with hose kit.
For safety, the pump motor has an automatically resetting thermal protector that automatically 
will turn off the pump if it becomes too hot. Overuse of this feature will damage the pump and 
void the warranty.

Once the thermal protector detects that the pump has cooled to a safe temperature, it will allow 
the pump to operate normally. If the pump is plugged in, it may restart unexpectedly.

Make certain the electrical power source is adequate for the requirements of the pump.

ALWAYS disconnect the power to the pump and drain all water from the system before 
servicing.

Secure the pump on a solid base to keep the pump vertical and above mud and sand during
operation to maximize pumping efficiency and prevent clogging and premature pump failure.

Secure the discharge hose before starting the pump. Pump torque may cause an unsecured 
discharge hose to “whip”, possibly causing personal injury and/or property damage.

Before using the pump, check hose for holes or excess wear, which could cause leaks, and be
sure hose is not kinked or making sharp angles. A straight hose allows the pump to move the
greatest amount of water quickly.

Check that all hose connections are tight to minimize leaks.

Connect the pump DIRECTLY to a grounded, GFCI outlet.

Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present
 a life-threatening safety hazard if the insulation becomes damaged or the connection ends fall
 into water.

 

2.

 

3.

 

4.

 

5.

 

6.

 

7.

 

8.

 

9.

3

Summary of Contents for UTP017-1

Page 1: ...MISSING PARTS please call our customer service department at 833 290 1189 before returning to your retailer Model UTP017 1 UTP033 2 OWNER S MANUAL Submersible Sump Pump Model UTP017 1 UTP033 2 El manual del propietario Bomba Sumergible de Sumidero Modelo UTP017 1 UTP033 2 FOR ENGLISH Pages 02 07 FOR SPANISH Pages 09 14 9815 3rd Street Road Louisville Kentucky 40272 Phone 833 290 1189 Email info ac...

Page 2: ...t Model UTP017 1 GPH of water Total Ft Head Max Head 5 ft 10 ft 15 ft 20 ft 1750 1550 1310 1030 29 5ft 25 ft 650 Property Specifications Voltage Horse Power Amps Max Head ft Max Flow GPH Discharge Size in Power cord length ft Model UTP033 2 PERFORMANCE Model UTP017 1 GPH of water Total Ft Head Max Head 115V 60Hz 1 3HP 4A 33 5 ft 2160 5ft 1 1 4 in 10 ft 5 ft 10 ft 15 ft 20 ft 2160 1950 1700 1450 33...

Page 3: ...age To minimize the potential for water damage due to pump failure please read the section of this manual regarding common pump problems and remedies or call 800 201 1360 This pump is not designed to function as a permanently installed sump pump It is also not engineered to be run continuously as a fountain or waterfall pump Because this pump has an oil filled motor it should NOT be used in water ...

Page 4: ... washer to minimize water leaks Follow all electrical and safety codes particularly the National Electrical Code NEC and in the workplace the Occupational Safety and Health Act OSHA This unit is designed only for use on 115 volts single phase 60 Hz and is equipped with an approved 3 conductor cord and 3 prong grounded plug DO NOT REMOVE THE GROUND PIN UNDER ANY CIRCUMSTANCES The 3 prong plug must ...

Page 5: ... the outlet OPERATION INSTRUCTIONS NOTICE Make certain you unwind the garden hose completely Kinks in the hose will restrict the pump preventing it from priming which is the first step to pumping water The water level must be at 1 in for the pump to prime and operate Once the pump A has removed the water down to 1 4 in unplug the pump CAUTION Failure to unplug it will result in the pump going into...

Page 6: ...Plug disconnected 4 Thermal overload 5 Corroded plug 6 Motor failed 1 Replace fuse 2 Reset breaker 3 Secure plug 4 Unplug the pump for 30 minutes then plug in 5 Clean plug prongs 6 Call 833 290 1189 1 Clean screen 2 Straighten hose 3 Clean airlock release feature 4 Use larger diameter hose 5 Use shorter hose 6 Reassemble impeller 7 Call 833 290 1189 1 Screen blocked 2 Hose kinked bent sharply or c...

Page 7: ...PARTS DIAGRAM PARTS LIST Part No Description 1 2 3 4 impeller sealing gasket pump bsse screen 1 2 3 4 7 ...

Page 8: ...n lesiones personales graves Si tiene cualquier PREGUNTAS PROBLEMAS PIEZAS FALTANTES por favor llame a nuestro departamento de servicio al cliente al 833 290 1189 antes de devolver a la tienda Model UTP017 1 UTP033 2 OWNER S MANUAL Submersible Sump Pump Model UTP017 1 UTP033 2 El manual del propietario Bomba Sumergible de Sumidero Modelo UTP017 1 UTP033 2 FOR ENGLISH Pages 02 07 FOR SPANISH Pages ...

Page 9: ...lo LPM de agua a un total de metros de cabeza Max Cabeza m UTP017 1 1 5m 3m 4 6m 6 1m 110 98 83 65 9m 7 6m 41 Propiedad Especificaciones Voltaje Caballo de fuerza Amperios Max Cabeza m Max Flujo LPM tamaño de la descarga Longitud del cable eléctrico Modelo UTP017 1 RENDIMIENTO Modelo LPM de agua a un total de metros de cabeza Max Cabeza m UTP017 1 1 5m 3m 4 6m 6 1m 10 2m 7 6m 115V 60Hz 1 3HP 4A 10...

Page 10: ...s por agua Para minimizar el potencial de daños por agua debido a una falla en la bomba lea la sección de este manual sobre problemas y soluciones comunes de la bomba o llame 833 290 1189 Esta bomba no está diseñada para funcionar como bomba de sumidero de instalación permanente Tampoco está diseñada para funcionar continuamente como una bomba para fuentes o cascadas Debido a que esta bomba tiene ...

Page 11: ...ás a la salida de la bomba No se incluye AVISO Asegúrese de que el extremo de la manguera tenga una arandela de goma para minimizar fugas de agua Respete todos los códigos eléctricos y de seguridad especialmente el Código nacional de electricidad NEC por sus siglas en inglés y en el lugar de trabajo la Administración de Salud y Seguridad Ocupacional OSHA por sus siglas en inglés Esta unidad está d...

Page 12: ...en el tomacorriente INSTRUCCIONES DE FUNCIONAMIENTO AVISO Asegúrese de desenrollar completamente la manguera para jardín Las torceduras en la manguera restringen la bomba y evitan su cebado el cual es el primer paso para bombear agua El nivel de agua debe ser 2 54 cm para el cebado y funcionamiento de la bomba Una vez que la bomba A retira agua hasta un nivel de 1 27 cm desenchufe la bomba PRECAUC...

Page 13: ... motor 1 Cambie el fusible 2 Restablezca el interruptor 3 Fije el enchufe 4 Desenchufe la bomba durante 30 minutos luego enchúfela 5 Limpie las clavijas del enchufe 6 Llame al 833 290 1189 1 Limpie la malla 2 Enderece la manguera 3 Limpie la característica de liberación de bloqueo de aire 4 Use una manguera de mayor diámetro 5 Use una manguera más corta 6 Vuelva a ensamblar el impulsor Consulte la...

Page 14: ...14 DIAGRAMA DE PIEZAS LISTA DE PARTES Número de pieza Descripción 1 2 3 4 1 2 3 4 impulsor junta de estanqueidad base de la bomba rejilla ...

Reviews: