Acquaer AUP033-5 Manual Download Page 3

SAFETY INFORMATION

WARNING

The  pump  will  only  turn  on  when  water  reaches  approximately  1-1/2  in.,  and  will  turn  off
automatically at approximately 1/4 in. of water remaining. Place the pump in the lowest possible
location so that water will flow toward the pump and turn the pump on.

Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in
the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can
cause an explosion or fire, resulting in property damage, serious personal injury and/or death.
Always disconnect the pump from its power source before inspection.

Do not stand in water when the pump is connected. Do not handle pump with wet hands.

Do not touch the pump housing while it is operating, as the pump may be HOT and can cause serious
skin burns.

Do not disassemble the motor housing. This pump has NO repairable internal parts, and disassembling
may cause an oil leak or dangerous electrical wiring issues. 

CAUTION

This submersible utility pump is designed for portable applications. It can drain or remove water from the
following:  pits,  sinks,  window  wells,  basements,  swimming  pool  covers,  boats,  low  spots  in  yards,  or
other  flooded  areas.  This  pump  has  not  been  tested  or  approved  for  use  in  swimming  pools  or  in
salt-water marine areas.
This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for
many years when properly installed, maintained, and used. However, inadequate electrical power to the
pump, or blockage by ice, dirt, or debris may cause the pump to fail, potentially bringing about additional
water damage. To minimize the potential for water damage due to pump failure, please read the section
of this manual regarding common pump problems and remedies or call 1-888-538-0082.

This pump is not designed to function as a permanently installed sump pump. It is also not engineered
to be run continuously as a “fountain” or “waterfall” pump. Because this pump has an oil-filled motor, it
should NOT be used in water containing fish. The pump should be used with a 3/4 in. or larger inside
diameter garden hose, or use with hose kit (not included).

For safety, the pump motor has an automatically resetting thermal protector that automatically will turn
off the pump if it becomes too hot. Overuse of this feature will damage the pump and void the warranty.
Once the thermal protector detects that the pump has cooled to a safe temperature, it will allow the
pump to operate normally. If the pump is plugged in, it may restart unexpectedly.

ADDITIONAL SAFETY PRECAUTIONS

Know the pump applications, limitations, and potential hazards.

1.

Make certain the electrical power source is adequate for the requirements of the pump.

2.

ALWAYS disconnect the power to the pump and drain all water from the system before servicing.

3.

Secure the pump on a solid base to keep the pump vertical and above mud and sand during operation to
maximize pumping efficiency and prevent clogging and premature pump failure.

4.

Secure the discharge hose before starting the pump. Pump torque may cause an unsecured discharge
hose to “whip”, possibly causing personal injury and/or property damage.

5.

Before  using  the  pump,  check  hose  for  holes  or  excess  wear,  which  could  cause  leaks,  and  be  sure
hose is not kinked or making sharp angles. A straight hose allows the pump to move the greatest amount
of water quickly.

6.

Check that all hose connections are tight to minimize leaks.

7.

Connect the pump DIRECTLY to a grounded, GFCI outlet.

8.

Extension  cords  may  not  deliver  sufficient  voltage  to  the  pump  motor.  Extension  cords  present  a
life-threatening safety hazard if the insulation becomes damaged or the connection ends fall into water.

9.

Make certain the electrical circuit to the pump is protected by a 10-amp or larger fuse or circuit breaker.

10.

Periodically inspect pump and system components, to be sure pump inlets are free of mud, sand, and
debris. DISCONNECT PUMP FROM THE POWER SUPPLY BEFORE INSPECTING.

11.

Wear safety glasses at all times when working with pumps.

12.

Follow all electrical and safety codes, particularly the National Electrical Code (NEC) and in the
workplace, the Occupational Safety and Health Act (OSHA).

13.

3

Summary of Contents for AUP033-5

Page 1: ...ad carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury If you have any QUESTIONS PROBLEMS MISSING PARTS please call our customer service department at 1 888 538 0082 before returning to your retailer 160 Pennsylvania Ave Unit 4 Vaughan ON L4K 4A9 FOR ENGLISH Pag...

Page 2: ... 5 ft 2160 3 4 in 10 ft 5 ft 10 ft 15 ft 20 ft 2160 1950 1700 1450 33 5ft For best performance the maximum recommended hose length is 50 ft The pumping capacity or water flow rate of any pump depends on several factors The larger the inside diameter and the shorter the length of hose the less pressure that is lost or the larger the flow rate If the hose runs uphill or is extra long use a larger di...

Page 3: ...d motor it should NOT be used in water containing fish The pump should be used with a 3 4 in or larger inside diameter garden hose or use with hose kit not included For safety the pump motor has an automatically resetting thermal protector that automatically will turn off the pump if it becomes too hot Overuse of this feature will damage the pump and void the warranty Once the thermal protector de...

Page 4: ...ded use Always use handle to lift pump Never use power cord to lift pump To avoid skin Before beginning assembly of product make sure all parts are present Compare parts with package contents list If any part is missing or damaged do not attempt to assemble the product Estimated Assembly Time New installation 5 minutes Materials Required for Assembly not included Garden Hose or Hose Kit The pump s...

Page 5: ...ater or other debris is not still contacting the sensor probes The pump can remain plugged in and will automatically turn back on when water reaches approximately 1 1 2 in again TROUBLESHOOTING Note Do not disassemble the motor housing This motor has NO repairable internal parts and disassembling may cause an oil leak or dangerous electrical wiring issues Problem Possible Cause Corrective Action P...

Page 6: ...6 PARTS DIAGRAM PARTS LIST Part No Description 1 2 3 4 swich box check valve adapter impeller pump base screen 5 1 2 4 3 5 ...

Page 7: ...AVERTISSEMENT Lisez soigneusement et comprennez toutes les INSTRUCTIONS D ASSEMBLAGE ET D OPERATION avant de fonctionner Le non respect des règles de sécurité et des autres mesures de sécurité de base peut provoquer des blessures graves Si vous avez aucunes QUESTIONS AUCUNS PROBLEMES AUCUNES PARTIES MANQUANTES rappellez notre service à la clientèle au 1 888 538 0082 avant de retourner à votre déta...

Page 8: ...4A 10 2m 136 3 4 in 3m 1 5m 3m 4 6m 6 1m 136 123 107 91 10 2m Pour de meilleures performances la longueur maximale recommandée du tuyau est de 50 pieds La capacité de pompage ou le débit d eau d aucune pompedépend des plusieurs facteurs Le diamètre intérieur plus large et la longueur plus courte du tuyau la pressioninférieurequi est perdue ou le débit plus large Si le tuyau fonctionne en montant o...

Page 9: ...e puisard installée de façon permanente Il n est pas également conçupour être exécutéen continu comme une pompe de fontaine ou de cascade Parce que cettepompe a un moteur rempli d huile elle NE devrait PAS être utilisée dans de l eau contenant des poissons Cette pompe devrait être utilisée avec 3 4 pouce de ou le tuyau d arrosage de plus grand diamètre intérieur ou utilisez avec le kit de tuyau no...

Page 10: ...oltages monophasé 60 Hz et est équipé d un cordonà 3 conducteurs approuvéet une prise de mise à la terre de 3 broches NE RETIREZ PAS LA BROCHE DE TERRE EN TOUTES CIRCONSTANCES La prise à3 broches doit être directement insérée dans un réceptaclecorrectement installée et à3 broches de mise à la terre de type de mise à la terre N utilisez pas la pompe avec uneprise murale à 2 broches Remplacez la pri...

Page 11: ...sondes de détection La pompe peut rester branchée et revenir automatiquement en arrière lorsque l eau atteint environ 1 1 2 pouce à nouveau DEPANNAGE NOTE Ne démontez pas le carter du moteur Ce moteur n a pas de pièces internes réparables et le désassemblage peut provoquer une fuite d huile ou de problèmes dangereux de câblage électrique PROBLÈME CAUSE POSSIBLE ACTION CORRECTIVE La pompe ne démarr...

Page 12: ...12 PIÈCES SCHÉMA LISTE DES PIECES Numéro de pièce La description 1 2 3 4 1 2 4 3 5 5 boîte d interrupteur adaptateur du clapet anti retour impelleur base de la pompe écran ...

Reviews: