20
3.3 Is the setting of the temperature appropriate?
3.4 Is there too much food or overheating food in it?
3.5 Does there open the door frequently?
3.6 Is the door completely closed?
3.7 Does the gasket destroyed or distort?
3.8 Is the thermostat good operation?
3.9 Does the gas leak?
Ice up in the freezing
chamber
4.1 Is the setting of the temperature appropriate?
4.2 Is there multi-moisture food and too close to the back wall of the refrigerator?
4.3 Is the ambient temperature too low?
4.4 Is the electric parts on good condition, specially the thermostat wich will cause the
unit non-stopping .
Abnormal noise
5.1 Is the refrigerator stably placed?
5.2 Does the refrigerator bump other objects?
5.3 Whether the internal accessory of the refrigerator is in the right place.
5.4 Whether the water plate of compressor is fall from the unit.
5.5 Does the tube of the refrigeration system bump each other?
5.6 The noise sound likes Water flow inside the refrigerator ,in fact ,it is normal, which is
caused both when refrigerator start and shut-down; in addition, frost-dissolving
causes this sound, too, which is a normal phenomenon.
5.7 There will be a cracking sound in the cabinet ,when the cabinet or cabinet accessory
contracting or expanding, this sound will be made, which is normal.
5.8 The motor operation sound in the compressor is appears to be louder at night or
begin starting. which is a normal phenomenon; also the uneven placing would lead to
too much running noise.
There is a peculiar
smell in the units
6.1 Is the food with special smell sealed tight?
6.2 Does it have long time storing food or degenerated food?
6.3 Whether the internal cabinet needs cleaning.
the forefront or the
middle cabinet heats
7.1 As fridge Anti-condensation tube is placed here and caused the above phenomenon,
which is normal.
Refrigerator’s two
sides or the back heat
8.1 As condensation tube is placed here and caused the above phenomenon, which is
normal.
the cabinet surface
condensation
9.1 Air humidity is too large.
◆
The solution for the common problem.
1.Cooling is not enough good
(Many reasons might cause that cooling not enough good, as blow :)
Reason
analysis
Solutions
1) Leakage of Gas
If some gas leaked unit will work not well.
Phenomenon of failure:
a. lower pressure of liquid cycle system
b. high temperature of copper tube of
discharging gas, hand feels very hot.
First find out the point of leaking on
tube, and then sealed it, vacuuming
it, finally recharge with Gas.