Component Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor  
before servicing, unless testing requires power. 

 

 

 

October 2013 

16500048 

©2013 ACP, Inc.

 

4

 

All Amana and Menumaster microwave oven power outputs are rated using the IEC705 standards. Using the 

IEC705 test method requires precision measurements and equipment that is not practical to be performed in the 
field. Using the test shown below will indicate if the oven performance is satisfactory. 

 

Test equipment required: 

 

1000 ml test container and thermometer.  

 

Digital watch / watch with a second hand for use on ovens with electromechanical timers. 

Important Notes: 

 

Low line voltage will cause low temperature rise / power output. 

 

Ovens must be on a dedicated circuit, properly grounded, and polarized. Other equipment on the same 
circuit may cause a low temperature rise / power output. 

 

This test and results are not a true IEC705 test procedure and are only intended to provide servicers with an 
easy means of determining if the microwave oven cooking output is correct. 

Procedure 

1.  Fill the test container to the 1000 ml line with cool tap water. 

NOTE:

 

Water temperature should be approximately 60°

 

F / 16° C. 

2.  Using the thermometer, stir water for five to ten seconds; measure, and record the temperature (T1). 
3.  Place test container of water in the center of oven cavity and close door. 
4.  Heat the water for a 33-second full power cycle. 

NOTE:

 

Use a digital watch or a watch with a second hand for ovens with electromechanical timers. 

5.  At end of the cycle, remove test container. Using the thermometer, stir water for five to ten seconds and record 

temperature (T2). 

6.  Subtract the starting water temperature (T1), from the ending water temperature (T2) to obtain the temperature 

rise (

T). 

7.  If the temperature rise (

T) meets or exceeds the minimum, the test is complete. If the temperature rise (

T) 

fails to meet the minimum temperature rise, test the line voltage to verify it is correct. Then repeat steps 1 - 6 
making sure to change the water. If the temperature rise (

T) fails to meet the minimum temperature rise again 

the oven will require service. 

Minimum Temperature Rise at Thirty -Three (33) Seconds Run Time 

Cooking 

Cooking 

Cooking 

Cooking 

(°F) 

Power Output 

(°F) 

Power Output  

(°C) 

Power Output 

(°C) 

Power Output 

10 ................. 1000 

20 ................. 2000 

5  .............. 1000 

11 ............ 2000 

11 ................. 1100 

21 ................. 2100 

5.5 ............ 1100 

11.5 ......... 2100 

12 ................. 1200 

22 ................. 2200 

6.5 ............ 1200 

12 ............ 2200 

14 ................. 1400 

24 ................. 2400 

7.5 ............ 1400 

13 ............ 2400 

17 ................. 1700 

25 ................. 2500 

9.5 ............ 1700 

13.5 ......... 2500 

18 ................. 1800 

27 ................. 2700 

10 ............. 1800 

15 ............ 2700 

19 ................. 1900 

30 ................. 3000 

10.5 .......... 1900 

16.5 ......... 3000 

 
 

Summary of Contents for RMS510TS

Page 1: ... of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models RMS510TS Power Source Voltage AC 220 VAC Amperage Single Unit 15 A Frequency 50 Hz Single Phase 3 wire grounded X Receptacle AW208 AWIN Plug AW208 AWIN Power Output Nominal microwave energy IEC705 1000 Watts Minimum temperature rise T 10º F 5º C Opera...

Page 2: ...ghest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace capacitor Terminal to Case Infinite resistance Magnetron Discharge Capacitors Remove wires from magnetron and connect ohmmeter to terminals Also check betwe...

Page 3: ...w on transformer Terminal 4 to any other terminal 2 0 Ω Infinite Less than 1 Ω 160 170 Ω Infinite resistance If not replace transformer Secondary Interlock Switch Primary Interlock Switch Monitor Interlock Switch Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NC Monitor Terminal C to NO Primary Logic Terminal C to NO Secondary With door cl...

Page 4: ... NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 5 At end of the cycle re...

Page 5: ...tic Diagrams WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power October 2013 2013 ACP Inc 16500048 5 DANGER ...

Reviews: