56
Change Option Code #10 to OFF
Option #12 This is activated at the factory.
It will appear every 7 days.
Note:
Customer can change this option
as desired. See Quick Start Reference
Guide section.
PREHEAT
OVEN NOT AT
PREHEAT
OVEN NOT AT
TEMPERATURE
FILTER
CLEAN
FILTER
CLEAN
1. At the end of a cook cycle and the food is removed and the door is closed the display indicates.
2. When a pad is pressed the display indicates.
1. Normal do not service the oven for this.
RESTART
PROGRAM
CHECK DOOR
1. Door not fully closed.
2. Inoperative Power Relay.
3. Inoperative Primary Interlock Switch.
4. Inoperative Secondary Interlock Switch.
5. Secondary Interlock Switch out of Adjustment.
6. Broken or Loose Wire Connection.
7. Inoperative HV System (Magnetron).
See component test procedures section
for testing procedures and results.
CHASSIS
MEMORY
ERROR
1. Unplug the oven and remove right side panel.
2. Disconnect the data key board connector
from the display board (Figure 1).
3. Plug the oven in (See Caution below).
4. Carefully reinstall data keyboard connector
onto the display board.
5. Press and hold Pad 2 ( The display will
indicate user options).
6. Press Save pad.
Note:
If chassis memory error returns replace
data keyboard.
OPERATIONAL CODES
Data Key Connector
Figure 1
CAUT IO N
Oven is energized, use care when
plugging connector into data key
board.
!"#$%&'("")*+,-./01234-5-./01236-5-7/01234-5-7/01236
Summary of Contents for MXP5201
Page 1: ...Service Training Manual High Speed Combination Oven MXP 50 Hz December 2011 16400017 ...
Page 3: ...1 Important Safety Information 1 ...
Page 11: ...9 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Quick Start Reference Guide 3 ...
Page 26: ...24 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Oven Construction 4 ...
Page 28: ...26 Door Construction Door Assembly ...
Page 35: ...33 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Interlock Switch Service 5 ...
Page 37: ...35 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Oven Performance Test 6 ...
Page 41: ...39 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Component Testing Procedures 7 ...
Page 44: ...42 AXP5201 AXP5203 MXP5201 MXP5203 50 Hz Service Test 8 ...
Page 53: ...51 AXP5201 AXP5203 MXP5201 MXP5203 50 Hz Troubleshooting 9 ...
Page 59: ...57 AXP5201 AXP5203 MXP5201 MXP5203 50 Hz Display Diagnostics 10 ...
Page 61: ...59 MXP5221 MXP5223 50 Hz Service Test 11 ...
Page 69: ...67 MXP5221 MXP5223 50 Hz Troubleshooting 12 ...
Page 75: ...73 MXP5221 MXP5223 50 Hz Display Diagnostics 13 ...
Page 77: ...75 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Wiring Diagrams Schematics 14 ...
Page 80: ...78 Wiring Diagram Sample MXP5221 ...
Page 82: ...BA Wiring Diagram Sample MXP5223 ...
Page 84: ...2011 ACP Inc Cedar Rapids Iowa 52404 Part No 16400017 Printed in U S A 12 11 CCCD 7 D7 ...