41
Illustration
Component
Test
Results
Transformer
Discharge Capacitor
Remove all wires from terminals.
Measure resistance from:
230 to COM..................................................
208 to COM..................................................
230 to Ground ..............................................
208 to Ground ..............................................
Terminal 5 to 6 .............................................
Terminal 4 to Ground...................................
Less than 1
Less than 1
Infinite
Infinite
Less than 1
Approximately
Convection blower
motor
Use Service test to verify operation
ST1-1 to ST1-3
BK BU
Convection heating
element (Top)
Disconnect wires from terminals.
Measure resistance across heating
element.
Element
2000 W .......................
Approximately 19 - 22
Heating
element (Bottom)
Disconnect wires from terminals.
Measure resistance across heating
element.
Element
3000 W .........................
Approximately 14
Resistance thermal
device (RTD)
Temperature
32
!
F
""
.............................................................
350
!
...........................................................
Resistance
1000
1654
0
1
2 4 6 8
Relay (Power)
This relay contains a
diode in the coil
circuit.
Measure resistance from:
Terminal 0 to terminal 1 (coil) ............
0
1
2
4
6
8
Approximately 6 to 7 M
NOTE:
Analog meter is recommended
for measurement.
NOTE:
If using a digital meter it must
contain a battery of 6 volts minimum.
Wire harness
High voltage board
to display module
harness
Test continuity of wires .......................
Indicates continuity
----------------------------------------------
Line Voltage
ST2
GN - YL - OR -BU-------------------------------
Disconnect ST2
Fan should operate at
High Speed
Primary switch
Secondary switch
Monitor Interlock
switch
Com
NO
NC
ST1
ST2
NC to Com
NO to Com
Indicates continuity
Indicates infinity
COM
NC
NO
NC to Com
NO to Com
Indicates continuity
Indicates infinity
3
1
2
1 to 2
1 to 3
Indicates continuity
Indicates infinity
(0
!
C)
(177
!
C)
46
7
6
2
8
3
1
5
4
9
10
Limiter
Note:
Unit must have
power applied to test
Limiter.
Red - Orange Lead Terminals
Line Voltage
Yellow - Yellow Leads disconnected from
Limiter
24vdc across yellow leads
(Polarity must be correct)
Terminal 6 - Terminal 7
0
"
Indicates continuity
..
.......................
.
.......................
....................... .......................
J2
GND
J1
Power supply board
-24 Volt
Red to White lead - J2 Power Supply Board
Approximately 24vdc
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Component Testing Procedures
Summary of Contents for MXP5201
Page 1: ...Service Training Manual High Speed Combination Oven MXP 50 Hz December 2011 16400017 ...
Page 3: ...1 Important Safety Information 1 ...
Page 11: ...9 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Quick Start Reference Guide 3 ...
Page 26: ...24 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Oven Construction 4 ...
Page 28: ...26 Door Construction Door Assembly ...
Page 35: ...33 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Interlock Switch Service 5 ...
Page 37: ...35 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Oven Performance Test 6 ...
Page 41: ...39 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Component Testing Procedures 7 ...
Page 44: ...42 AXP5201 AXP5203 MXP5201 MXP5203 50 Hz Service Test 8 ...
Page 53: ...51 AXP5201 AXP5203 MXP5201 MXP5203 50 Hz Troubleshooting 9 ...
Page 59: ...57 AXP5201 AXP5203 MXP5201 MXP5203 50 Hz Display Diagnostics 10 ...
Page 61: ...59 MXP5221 MXP5223 50 Hz Service Test 11 ...
Page 69: ...67 MXP5221 MXP5223 50 Hz Troubleshooting 12 ...
Page 75: ...73 MXP5221 MXP5223 50 Hz Display Diagnostics 13 ...
Page 77: ...75 AXP5201 AXP5203 MXP5201 MXP5203 MXP5221 MXP5223 50 Hz Wiring Diagrams Schematics 14 ...
Page 80: ...78 Wiring Diagram Sample MXP5221 ...
Page 82: ...BA Wiring Diagram Sample MXP5223 ...
Page 84: ...2011 ACP Inc Cedar Rapids Iowa 52404 Part No 16400017 Printed in U S A 12 11 CCCD 7 D7 ...