Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
All ACP microwave oven power outputs are rated using the IEC705 standards. Using the
IEC705 test method requires precision measurements and equipment that is not practical to be performed in the
field. Using the test shown below will indicate if the oven performance is satisfactory.
Test equipment required:
1000 ml test container and thermometer.
Digital watch / watch with a second hand for use on ovens with electromechanical timers.
Important Notes:
Low line voltage will cause low temperature rise / power output.
Ovens must be on a dedicated circuit, properly grounded, and polarized. Other equipment on the same
circuit may cause a low temperature rise / power output.
This test and results are not a true IEC705 test procedure and are only intended to provide servicers with an
easy means of determining if the microwave oven cooking output is correct.
Procedure
1. Fill the test container to the 1000 ml line with cool tap water.
NOTE:
Water temperature should be approximately 60°
F / 16° C.
2. Using the thermometer, stir water for five to ten seconds; measure, and record the temperature (T1).
3. Place test container of water in the center of oven cavity and close door.
4. Heat the water for a 33-second full power cycle.
NOTE:
Use a digital watch or a watch with a second hand for ovens with electromechanical timers.
5. At end of the cycle, remove test container. Using the thermometer, stir water for five to ten seconds and record
temperature (T2).
6. Subtract the starting water temperature (T1), from the ending water temperature (T2) to obtain the temperature
rise (
T).
7. If the temperature rise (
T) meets or exceeds the minimum, the test is complete. If the temperature rise (
T)
fails to meet the minimum temperature rise, test the line voltage to verify it is correct. Then repeat steps 1 - 6
making sure to change the water. If the temperature rise (
T) fails to meet the minimum temperature rise again
the oven will require service.
Minimum Temperature Rise at Thirty -Three (33) Seconds Run Time
T
Cooking
T
Cooking
T
Cooking
T
Cooking
(°F)
Power Output
(°F)
Power Output
(°C)
Power Output
(°C)
Power Output
10..................1000
20 .................2000
5 ...............1000
11 ............2000
11..................1100
21 .................2100
5.5 .............1100
11.5 .........2100
12..................1200
22 .................2200
6.5 .............1200
12 ............2200
14..................1400
24 .................2400
7.5 .............1400
13 ............2400
17..................1700
25 .................2500
9.5 .............1700
13.5 .........2500
18..................1800
27 .................2700
10 ..............1800
15 ............2700
19..................1900
30 .................3000
10.5 ...........1900
16.5 .........3000
Summary of Contents for Menumaster DEC21E2
Page 3: ...1 Important Safety Information 1 ...
Page 13: ...11 DEC 50 Hz Components 4 ...
Page 18: ...16 Components Sample Door Assembly 5 6 7 8 7 9 7 7 6 6 7 6 ...
Page 19: ...17 Disassembly Inner door window removal Switch replacement door adjustment 5 ...
Page 26: ...24 Airflow 7 ...
Page 27: ...25 Air filter must be in place and cleaned regularly Some Models ...
Page 28: ...26 Component Testing Procedures 8 ...
Page 34: ...32 Troubleshooting Intial Power Up Standby Condition Cook Condition 9 ...
Page 38: ...36 Wiring Diagrams Schematics 10 ...
Page 47: ...45 Notes ...
Page 48: ...www acpsolutions com 01 23 45 6 7 7 8 94 7 1 8 1 ...