28
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Illustration
Component
Test
Results
1
2
4
7
6
5
8
Terminal 1
230 V
Terminal 2
Common
Transformer
# 4
# 1
# 2
# 5
# 6
# 7
# 8
1.0 F
-300 MA
-300 MA
1.0 F
Discharge Capacitors
Remove all wires from terminals.
Measure resistance from:
Terminal 1 to 2................................................
Terminal 5 to 6................................................
Terminal 7 to 8................................................
Terminal 4 to Ground screw on transformer...
Terminal 4 to any other terminal.....................
Gray
Pink
1
2
1.0
.
Less than 1
.
Less than 1
.
30
.
Infinite resistance. If not, replace
transformer.
Primary /
Logic
Secondary
Mo nitor
Interlock switch
assembly
Disconnect wires to switch.
With door open measure resistance from:
Terminal C to NC Monitor..........................
Terminal C to NO Primary / Logic..............
Terminal C to NO Secondary ....................
With door closed measure resistance from:
Terminal C to NC Monitor..........................
Terminal C to NO Primary / Logic..............
Terminal C to NO Secondary ....................
Door Closed
Primary / Logic C
NC
NO
C
C
NO
Secondary
Monitor
Continuity.
Infinite.
Infinite.
Infinite.
Continuity.
Continuity.
Touch Panel
Assembly
Continuity is indicated as 100
and below.
Pin 1:
Ground.
Pad
1
2
3
4
5
6
7
8
9
0
Start
Stop/Reset
Power Level
X 2
Time Entry
Pins
8 & 10
7 & 10
6 & 10
5 & 10
4 & 10
3 & 10
8 & 9
7 & 9
6 & 9
5 & 9
4 & 9
4 & 8
5 & 8
6 & 8
7 & 8
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Wire Harness
Test continuity of wires ................................... Continuity.
!"#$%&'&(%)%*&+,&-*,./0+&
1%02& 2%%+&),*&#*,#%*&32"&
*%454+!60%&7!$/%8
Summary of Contents for Menumaster DEC21E2
Page 3: ...1 Important Safety Information 1 ...
Page 13: ...11 DEC 50 Hz Components 4 ...
Page 18: ...16 Components Sample Door Assembly 5 6 7 8 7 9 7 7 6 6 7 6 ...
Page 19: ...17 Disassembly Inner door window removal Switch replacement door adjustment 5 ...
Page 26: ...24 Airflow 7 ...
Page 27: ...25 Air filter must be in place and cleaned regularly Some Models ...
Page 28: ...26 Component Testing Procedures 8 ...
Page 34: ...32 Troubleshooting Intial Power Up Standby Condition Cook Condition 9 ...
Page 38: ...36 Wiring Diagrams Schematics 10 ...
Page 47: ...45 Notes ...
Page 48: ...www acpsolutions com 01 23 45 6 7 7 8 94 7 1 8 1 ...