Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
January 2012
16500030
©2012 ACP, Inc.
7
Three Magnetron Models
# 1
# 1
# 1
# 1
# 2
# 2
# 2
# 2
# 3
# 3
# 3
# 3
H.V. System # 1
H.V. System # 2
H.V. System # 3
Top Rear Magnetron
Center Transformer
Bottom Center Capacitor
Diode
Center Triac
Top Front Magnetron
Left Transformer
Top Left Capacitor
Diode
Left Triac
Bottom Magnetron
Right Transformer
Right Capacitor
Diode
Right Triac