Once the Service Mode is initiated a menu of options and information is displayed. The menu screen can be
navigated by swiping up or down if needed. Some components can be activated from this menu
– See
example of Magnetron 1 (Right Side) below, by touching start to start or stop to stop.
Pressing the “back
arrow” will return back on screen. Pressing the “home” icon returns to opening screen.
Service Mode
Purpose
Comments
Oven Information
Provide service provider with door
cycles and magnetron tube hours of
operation
Press and the following will display:
Door Cycles:
Tube Hours:
Software Version
Displays the version of software and
firmware installed in the control
Press and the following will display:
SW:
EE:
App:
Magnetron 1
Right Side
System can be started and stopped
by pressing the Start or Stop icon.
The current amperage being drawn by the HV
system. 5 -12amps is considered normal. Look for
consistent reading with Magnetron 2 and Convection
Heater. This circuit is protected by fuse F3
Magnetron 2 (if)
Left Side
System can be started and stopped
by pressing the Start or Stop icon
The current amperage being drawn by the HV
system. 5 -12amps is considered normal. Look for
consistent reading with Magnetron 1 and Convection
Heater. This circuit is protected by fuse F4
PIN Code
1234
Summary of Contents for ARX51 Series
Page 9: ...7 ...
Page 10: ...8 ...
Page 11: ...9 ...
Page 12: ...10 ...
Page 13: ...11 ...
Page 15: ...CARE AND CLEANING 13 ...
Page 30: ...CONTROL BOARD WIRING 28 ...
Page 31: ...SCHEMATICS DIAGRAMS MRX51 ...
Page 32: ...MRX51 ...
Page 33: ...MRX51U ...
Page 34: ...MRX51U ...
Page 35: ...MRX52 ...
Page 36: ...MRX52 ...
Page 37: ...MRX523 ...
Page 38: ...MRX523 ...