Thank you for purchasing this Acoustic Energy product. As a valued customer 

we would like to keep you up to date with all news and events including new 

products, exhibitions and exclusive promotions. To enable us to communicate 

these exciting developments please go to our website - www.acoustic-energy.co.uk 

- and complete the ownership registration form.

Perhaps more than any other professional audio product, monitors are sensitive 

to installation so please take a little time to read this manual and to follow, as far 

as practical, the installation guidelines it contains. Careful installation will help 

ensure that your monitors perform optimally.

This manual covers both the Active and Passive variants of the AE22. Following this 

introduction, the Manual is divided into sections covering installation, positioning, 

passive connection, active connection, active controls, listening, specifications, 

warranty and contact information. We recommend that you read at least the first 

six sections carefully before installing and using your AE22s. In the case of the 

AE22 Active please also read the Important Safety Instructions below.

AE22s are intended to be used mounted horizontally 

either on a mixing-desk meter-bridge or on 

speaker floor-stands in relative proximity to the 

rear room boundary. Alternative, on-wall, mounting 

arrangements such as wall brackets are possible 

although these may result in less consistent 

performance. If brackets are to be used they should be 

as rigid as possible and firmly attached to brick-built 

walls.

The construction style, rigidity and dimensions of 

the floor-stands are of critical significance to the 

performance of the AE22. Stands should broadly follow 

the specification below. Your retailer or distributor will 

be able to offer advice.

Recommended Floor-stand Specification.

Construction Style:

  

Direct coupled pillared.

Mass Loading:

 

 

Preferred.

Overall height:

 

 

 As appropriate for AE22 

tweeter to be at head 

height when seated.

Top plate Dimensions

 

Minimum width:

   

230 mm 

Maximum width:

   

330 mm 

Minimum depth:

   

200 mm 

Maximum depth:

   

290 mm

Top plate interface:

   

 Direct coupled tri-point 

or damped-compliance.

Floor interface:

 

 

 Floor spikes (M6 

minimum).

1. Introduction

Important Safety Instructions

Ensure that your AE22 Active is set to the appropriate mains input voltage before it is 
connected to a mains socket. The warranty does not cover damage caused by incorrect mains 
voltage.

. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with dry cloth.

7. Do not block any ventilation openings. Install in accordance with the manufacturer’s 
instructions.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other 
apparatus (including amplifiers) that produce heat.

9. Do not defeat the safety purpose of the grounding-type plug. A grounding type plug has 
two blades and a third grounding prong. The third prong is provided for your safety. If the 
provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet.

0. Protect the power cord from being walked on or pinched particularly at plugs, convenience 
receptacles, and the point where they exit from the apparatus.

. Only use attachments/accessories specified by the manufacturer.

2. Use only with the cart, stand, tripod, bracket, or table specified by the 
manufacturer, or sold with the apparatus. When a cart is used, use caution when 
moving the cart/apparatus combination to avoid injury from tip-over.

3. Unplug this apparatus during lightning storms or when unused for long 
periods of time.

4. Refer all servicing to qualified service personnel. Servicing is required when the apparatus 
has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been 
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or 
moisture, does not operate normally, or has been dropped.

5. The apparatus shall not be exposed to dripping or splashing and that no objects filled with 
liquids, such as vases, shall be placed on the apparatus.

6. The MAINS plug is used as the disconnect device, the disconnect device shall remain 
readily operable.

7. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

2. Installation

3. Positioning

The AE22 is both a heavy and a relatively delicate 

precision engineered product that can be damaged 

by inappropriate handling. Please take care when 

unpacking or moving the monitors not to touch either 

of the drivers. Damage to a driver will at best degrade 

performance and at worst result in complete failure.

The packaging should be retained for future use.

Summary of Contents for Professional Series AE22

Page 1: ...OWNERS MANUAL p a s s i v e a c t i v e...

Page 2: ...ve is set to the appropriate mains input voltage before it is connected to a mains socket The warranty does not cover damage caused by incorrect mains voltage 1 Read these instructions 2 Keep these in...

Page 3: ...ent exactly The most important thing is to experiment with the different options that are practical and find the one that works best AE22s need not be angled inward towards the listening position alth...

Page 4: ...onnected with the same polarity Positive speaker terminals should always be connected back to amplifier positive terminals and negative speaker terminals connected back to amplifier negative terminals...

Page 5: ...balanced and unbalanced line level signal inputs for connection to the monitor outputs of the mixing desk digital audio workstation or computer audio interface A three position switch provides 6dB of...

Page 6: ...n at 70Hz Flat is the un equalised response and Extend applies 3dB of gain at 40Hz LF Adjust should normally be left Flat Cut is intended to model the LF characteristic of smaller speakers while Exten...

Page 7: ...of as domestic waste but must be taken to a facility capable of re cycling them and appropriately handling any waste by products Contact your local authority for details of the nearest such facility...

Page 8: ...ited 16 Bridge Road Cirencester Gloucestershire GL7 1NJ Tel 44 0 1285 654432 Sales 44 0 1285 656890 Technical Fax 44 0 1285 654430 Email info acoustic energy co uk Web www acoustic energy co uk Manual...

Reviews: