background image

ACORN ENGINEERING FIELD SERVICE

TOLL FREE

 800-743-8259 • 

LOCAL

  626-855-4866 • 

FAX

 626-855-4863

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Please visit 

www.acorneng.com

for most current specifications.

®

MERIDIAN-EDGE  MODEL 3802

Date Revised: 08/02/19

Page 2 of 22

Part #: 6216-011-000

Provide:  110-120  VAC/60Hz/3A  (MAX)  electrical  receptacle  for  factory  supplied 
120VAC/9VDC, 100mA plug-in transformer when -SO and -SOS options are selected.

Provide:  110-120  VAC/60Hz/15A  dedicated  circuit  when  Dyson  Air  Blade  Faucet 
selected. Refer to Dyson installation instructions  for more information. 

Single Temp Valve Assembly: Recommended working water pressure is 30 PSI (2.07 
bars)  minimum  to  100  PSI  (6.89  bars)  maximum.  Maximum  temperature  is  130°F 
(54.4°C).  Maximum  outlet  temperature  is  recommended  is  105°F  (40.6°C).  Valve 
assembly  must  be  drained  prior  to  being  subjected  to  freezing  temperatures.  A 
checkstop is provided with this valve assembly.

Important:  Some  options  may  slightly  alter  installation. To  ensure  proper  installation 
review the manual thoroughly and verify rough-ins before beginning any work. File this 
manual with the owner or maintenance personnel upon completion of installation.

Prior to installation, supply lines must be flushed of all foreign material such as pipe 
dope, chips, or solder. Debris or foreign material in water supply may damage valve.

Teflon tape is recommended on all threaded waste and supply connections to reduce the 
possibility of leaks.

ANSI, UFAS or ADA compliance is subject to the interpretation and requirements of the 
local code authority and is the responsibility of the installer for verification.

Industry standard wall backing, for wall hung fixtures, is required. Installer provided wall 
anchors and wall anchoring hardware must be appropriate for wall construction, and 
have a minimum pull-out rating of 1000 lbs. (453.6 kg).

NOTE: Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth 
grounded per N.E.C. (National Electrical Code). 

T/P Mixing Valve Assembly: Recommended working water pressure is 30 PSI (2.07 
bars) minimum to 100 PSI (6.89 bars) maximum. Maximum hot water temperature is 
180°F  (82°C).  Temperature  adjustment  range  is  95°F-110°F  (43°C-48°C).  Valve 
assembly must be drained prior to being subjected to freezing temperatures. The valve 
assembly has a check integral to the inlet however, angle stop is to be provided by the 
installer.

Summary of Contents for Meridian Edge 3802

Page 1: ...ardware and Appropriate Tools Teflon Tape 9 32 10 Count Fixture Wall Anchors and Anchoring Hardware and Appropriate Tools INSTALLATION OPERATIONS MAINTENANCE MANUAL Please visit www acorneng com for m...

Page 2: ...this manual with the owner or maintenance personnel upon completion of installation Prior to installation supply lines must be flushed of all foreign material such as pipe dope chips or solder Debris...

Page 3: ...urrent specifications MERIDIAN EDGE MODEL 3802 ACCESSIBILITY COMPARISONS ADA ages 6 thru 12 ADA Adult OBC Ontario Building Code 131 8 22 33 4 34 RIM MAX 27 17 9 131 8 22 33 4 31 RIM MAX 27 17 9 131 8...

Page 4: ...8259 LOCAL 626 855 4866 FAX 626 855 4863 INSTALLATION OPERATIONS MAINTENANCE MANUAL Please visit www acorneng com for most current specifications DIMENSIONAL DATA MERIDIAN EDGE MODEL 3802 56 22 17 Dat...

Page 5: ...e Mounting Slots 9 Places H Wall Anchoring 9 16 Mounting Hole Support Bracket Mounting 2 Places B Waste Outlet for 1 1 2 O D P Trap by others D Supply Stub Outs with Stops for Valve 1 2 NPT Hot Cold S...

Page 6: ...antageous to install to the deck faucets soap dispensers or other accessories prior to wall mounting Hang deck and P Trap enclosure onto mounting bracket level 3and mount to the finished wall using 1...

Page 7: ...2 16 UNE Threads 2 Rubber Gasket 3 Flat Fiber Washer 4 1 1 2 16 UNI Rough Chrome Brass Jam Nut 5 1 1 2 16 x 1 1 4 UNI Close Ell with 3 8 NPT Clean Out Plug WASTE PLUMBING Assemble waste piping using t...

Page 8: ...ds the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting 1 Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensur...

Page 9: ...to the point of use as possible Wall anchors and anchoring hardware are by others 2 Connect hot and cold water to supply valve using 1 2 NPTE connections by others 3 Connect outlet of tempering valve...

Page 10: ...AIL C 1 Make sure power supply is disconnected from sensor and make short circuit on red wires See DETAIL A 4 Move hand to desired sensing distance See DETAIL B 2 Connect power supply to sensor Red li...

Page 11: ...ut 1 4 Min Ferrule Nut H Hand Operated 1 8 O D AIR TUBE 1 4 O D WATER LINE Leave a minimum 1 4 of polyethylene tubing through the Ferrule Nut on the pushbutton assembly This is necessary to ensure pro...

Page 12: ...ounting brackets provided as shown Wall anchors and anchoring hardware provided by installer A Install soap filler assembly to deck as shown B Attach 1 1 4 O D refill tube to soap filler assembly and...

Page 13: ...most current specifications MERIDIAN EDGE MODEL 3802 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 MODEL 3802 WD04 SOS MODEL 3802 WD04 PDM FINISHED LAYOUT...

Page 14: ...for most current specifications MERIDIAN EDGE MODEL 3802 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 FINISHED LAYOUTS SHOWN FOR REFERENCE MODEL 3802 H PD...

Page 15: ...embly Remove solenoid pull out plunger and spring and clean with scale remover solution or pressurized air Debris or scale in diaphragm Remove diaphragm and clean Sensor flashes once when user s hands...

Page 16: ...servomotor timer assembly Probable Cause Solution Valve riser tubing is crimped Straighten valve riser tubing Debris or scale in checkstop strainer Remove checkstop strainer and clean Blockage in val...

Page 17: ...olish on a cloth is recommended ROUTINE CLEANING Corterra should be kept clean at all times If maintained Corterra surfaces will retain their new clean appearance indefinitely Wash with a non abrasive...

Page 18: ...r COMPONENTS REPAIR PARTS Description Part No Diagram MOUNTING HARDWARE 0337 050 000 1 4 Stainless Steel Helical Lock Washer Stern Easy E B Sensor Operated Spout 9VDC 2993 400 001 SPOUTS Stern Easy E...

Page 19: ...Assembly Dyson Airblade Wash Dry Deck Mounted Short Faucet 3040 091 000 2566 270 001 9 VDC Plug In Transformer 0711 410 001 9 VDC Solenoid 2563 326 001 Stern Easy E Adapter Kit 6215 105 001 Date Revi...

Page 20: ...Description Part No Diagram ENCLOSURES Grid Strainer w Close Elbow 4926 062 001 ELECTRIC HARDWARE CONTINUED P Trap Waste Assembly 4970 040 003 Mounting Bracket Mounting Bracket 6216 204 199 WASTE ASS...

Page 21: ...VALVE Diagram Optional 2 Station Hand Operated Single Temp Metering Valve Assembly Optional 2 Station 9VDC Solenoid Single Temp Valve Assembly Optional T P 2 Station Hand Operated ASSE 1016 Mixing Va...

Page 22: ...parts shall be delivered to the company prepaid at City of Industry California for inspection Acorn will not be liable for the cost of repairs alterations or replacement or for any expense connected...