ACORN ENGINEERING FIELD SERVICE
TOLL FREE
800-743-8259 •
LOCAL
626-855-4866 •
FAX
626-855-4863
INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
®
MERIDIAN 3793
Please visit
www.acorneng.com
for most current specifications.
1
2
3
4
4
3
5
HINT: Teflon tape is recommended on all threaded waste and
supply connections.
Page 9 of 31
NOTE: Continuous waste assembly will require field cutting and
fitting by the installer.
27"
21"
54"
6"
Part #: 9927-143-001
Install grid strainer and close elbow to bowl
3
using plumber's putty.
Ã
1-1/2" -16 UNI Rough Chrome
Brass Jam Nut
Ä
1-1/2"-16 x 1-1/4" UNI Close Ell
with 3/8" NPT Clean-Out Plug
Á
Rubber Gasket
Â
Flat Fiber Washer
À
Grid Strainer w/ 1-1/2" -16
UNE Threads
Assemble continuous waste piping using teflon
4
tape on all threaded connections and make up
waste connections to 1-1/2” P-trap.
REVISED: 03/07/19