CORTERRA  SOLID SURFACE

®

Acorn's densified solid surface material is composed of 
recycled solid-surface polymer resin, aluminum trihydrate 
and fillers. It is resistant to stains, impact and burns and 
complies with ANSI Z124.3. It is attractive, durable and easy 
to maintain.

SOAP SYSTEMS

Acorn soap reservoirs and dispensers provide a dependable 
operation over long term when proper maintenance is 
performed and the correct soap is being used. The most 
common problem with soap systems is that the wrong 
viscosity (thickness) of soap is being used or high acidic pH 
levels are in the ingredients. Soap thickness can be best 
explained as no thicker or thinner than normal household 
liquid dish soap. The pH level of the soap should be 6.5 to 
8.5; more acidic soaps will corrode the metal parts and 
degrade rubber or plastic components.

WARNING:

 Some soap contains corrosive additives that 

can cause rust on stainless steel surfaces. Acorn 
recommends user/ maintenance personnel review MSDS 
reports of soap and possible corrosive additives noted.

CARE AND CLEANING OF STAINLESS 
STEEL SURFACE

Soap reservoirs and dispensers should be maintained 
periodically to clear residue. This should be done in hot 
water to clean the internal components. The valve should be 
pumped multiple times to thoroughly clean any residue 
inside. The reservoir and tubing should also be flushed and 
cleaned with hot water. In cases of extreme clogs, the 
dispenser should be disassembled and the parts thoroughly 
cleaned.

CARE, CLEANING, AND REPAIR 
OF CORTERRA  SOLID SURFACE

®

ROUTINE CLEANING

Corterra  should be kept clean at all times. If maintained, 

®

Corterra  surfaces will retain their new, clean appearance 

®

indefinitely. Wash with a non-abrasive all purpose cleaner 
and water, then rinse. Wipe dry. (Never use cleaners with 
strong chemicals such as toilet bowl cleaners, rust 
removers, ceramic cook top cleaners, laquer thinners or 
oven cleaners). To remove persistent stains use a Scotch 
Brite pad and an abrasive cleaner or a solution of household 
bleach and water (1 part water to 1 part bleach).

REPAIRING SURFACE DAMAGE

Surface damage, such as minor chips, scratches, burn 
marks and graffiti can be repaired with a fine grit abrasive 
cleanser, such as a Scotch-Brite pad or fine grit sandpaper. 
For more serious physical damage caused by vandals, an 
Acorn Solid Surface Repair Kit is available. Contact the 
factory for details. Refer to drawing #9927-160-002.

NORMAL CLEANING

Clean weekly or more often, as needed 
(especially high polishing surfaces)

IF SPOTS ARE STUBBORN OR IF YOU WISH TO TREAT A 
SCRATCH: synthetic, abrasive, general-purpose pads such 
as Scotch Brite are recommended. Apply the stainless steel 
cleaner/polish to the synthetic, abrasive pad and 
CAREFULLY rub out spot with cleaner/polish. 

Be sure to 

rub in the direction of the grain!

 Do not allow steel wool to 

come in contact with stainless steel. Steel particles can 
embed into the stainless steel surface and create rust.

RECOMMENDED CLEANING MATERIALS
-

  Sponge – natural or artificial

-

  Nylon or other soft-bristle material brush

-

  Soft cloth (as used on automobile finishes)

To remove smudges and fingerprints:

Wipe surfaces with a quality Stainless Steel Cleaner/Polish. 
Apply using a soft non-abrasive cloth, wipe surfaces with 
stainless steel cleaner/polish.

FOR HIGH POLISH STAINLESS STEEL

Note: High polish stainless steel surfaces should never 
come into contact with any abrasive cleaning brush, cloth or 
cleaning agent.

FOR TOUGH PROBLEMS

 CRES Cleaner specifically for rust stains (available from 

Acorn)

 Tarn-X for general stains

 #7 chrome polish

 Silver polish

To remove stubborn spots or to treat a scratch 

(Standard Satin Finish Only)

:

Use of synthetic, abrasive, general-purpose pads such as 
Scotch Brite is recommended. Apply the stainless steel 
cleaner/polish to the synthetic, abrasive pads and 
CAREFULLY rub out spot with cleaner/ polish. Be sure to 
rub in the direction of the grain! Do not allow steel wool to 
come in contact with the stainless steel. Steel particles can 
embed into the stainless steel surface and create rust!

RECOMMENDED CLEANING SOLUTIONS
-

  Hand dishwashing liquid/soft water solution

-

  Mild soap/soft water solution

-

  3M Stainless Steel Cleaner/Polish

-

  White vinegar/soft water solution 

 

  (for brightening, removing oil and

 

  hard water deposits)

-

  CLR Brand Cleanser or baking soda/soft

 

  water solution (for brightening, removing 

   hard water deposits)

-

  Club soda and sponge

To remove rust stains:

Wipe surfaces with CRES (available from Acorn) or 
equivalent cleaner. Use recommended solutions. Apply 
using a soft non-abrasive sponge. Rinse surfaces 
immediately after application. Always follow cleaner product 
directions provided. Afterwards, using a soft, non-abrasive 
cloth, wipe surfaces with stainless steel cleaner/polish.

Stainless steel should be kept clean at all times. If 
maintained, stainless steel surfaces will retain their new, 
clean, polished appearance indefinitely. To remove water 
spots or rust spots, stainless steel cleaner/polish on a cloth 
is recommended.

Part #: 9927-141-001

Page 22 of 28

Date: 03/07/19

Summary of Contents for MERIDIAN 3791-RO

Page 1: ...d Maintenance 22 Prior to Installation 2 TABLE OF CONTENTS Installation 8 16 Piezo Adjustment 17 19 Troubleshooting 20 21 Components Repair Parts 23 27 Rough Ins 5 7 Accessibility Overview 3 Dimension...

Page 2: ...with this valve assembly Teflon tape is recommended on all threaded waste and supply connections to reduce the possibility of leaks NOTE Receptacle s must be wired to a GFCI protected circuit Fixture...

Page 3: ...INTENANCE MANUAL MERIDIAN 3791 RO Please visit www acorneng com for most current specifications Page 3 of 28 ACCESSIBILITY OVERVIEW Part 9927 141 001 ADA ages 6 thru 12 ADA Adult 34 RIM MAX 4 9 121 2...

Page 4: ...LOCAL 626 855 4866 FAX 626 855 4863 INSTALLATION OPERATIONS MAINTENANCE MANUAL MERIDIAN 3791 RO Please visit www acorneng com for most current specifications Page 4 of 28 DIMENSIONAL DATA 15 53 4 4 1...

Page 5: ...of 28 Part 9927 141 001 ROUGH IN DIMENSIONS ADA Adult E D C B A Supply Stub Outs with Stops for Valve 1 2 NPT Hot Cold Supply Inlets Frame V Notch 120VAC 60 Hz 3A Max GFCI Protected Electrical Recept...

Page 6: ...ROUGH IN DIMENSIONS ADA AGES 6 THRU 12 YEARS E D C B A Part 9927 141 001 Supply Stub Outs with Stops for Valve 1 2 NPT Hot Cold Supply Inlets 3 8 Diameter Mounting Holes For Anchoring Points 13 Places...

Page 7: ...OUGH IN DIMENSIONS OBC ONTARIO BUILDING CODE E D C B A Part 9927 141 001 Supply Stub Outs with Stops for Valve 1 2 NPT Hot Cold Supply Inlets Waste Outlet for 1 1 2 O D P Trap Frame V Notch 3 8 Diamet...

Page 8: ...mounting hardware by others See DETAIL A Place deck assembly on frame making 2sure angle engages behind frame joggle See DETAIL C Assemble deck support flanges to outside of frame using 1 4 20 x 1 lon...

Page 9: ...p waste connections to 1 1 2 P trap Install grid strainer and close elbow to bowl 3using plumber s putty HINT Teflon tape is recommended on all threaded waste and supply connections NOTE Waste assembl...

Page 10: ...URE VALVE H HAND OPERATED SHOWN IMPORTANT for ST Single Temperature valves flush supply line Connect installer Bprovided 1 2 NPS flex hose to valve Before making up the supply connections the supply l...

Page 11: ...and cold water to supply valve using 1 2 NPTE connections 3 Connect outlet of tempering valve to spout s using 1 4 O D tube connections provided 4 Turn on hot and cold water supplies If any leaks are...

Page 12: ...t of sensor to distance of 2 to 4 within 5 seconds and wait until red light flashes quickly 2 Connect power supply to sensor Red light should be flashing 5 Hold hand at desired sensing distance until...

Page 13: ...remove access panel by removing 4 10 32 x 3 4 screws from front of fixture using allen head bit provided socket driver by others Replace access panel when finished SO BAT Sensor Operation Battery Pow...

Page 14: ...ut 1 4 Min Ferrule Nut H Hand Operated 1 8 O D AIR TUBE 1 4 O D WATER LINE Leave a minimum 1 4 of polyethylene tubing through the Ferrule Nut on the pushbutton assembly This is necessary to ensure pro...

Page 15: ...3 INSTALLATION OPERATIONS MAINTENANCE MANUAL MERIDIAN 3791 RO Please visit www acorneng com for most current specifications ACCESS PANEL INSTALLATION Part 9927 141 001 Install front and side access pa...

Page 16: ...soap tank 0 5 Gallons Overfilling may result in spilling and pooling of soap solution within the sprayhead enclosure and outside the soap tank WARNING Remove Corterra plug from 2top cover and soap acc...

Page 17: ...required then do not push the button and wait for the next timing mode To move on to the 20 sec timing mode pause and wait for the LED to flash 3 times now you are in the 20 sec timing mode and each t...

Page 18: ...o flash 3 times You are in the 20 sec timing mode immediately push the button 1 push equals 20 sec added to the total timing cycle You are in the 1 sec timing mode immediately push the button 1 push e...

Page 19: ...INSTALLATION OPERATIONS MAINTENANCE MANUAL Please visit www acorneng com for most current specifications BLACK RED BLACK SOLENOID CABLE RED POWER CABLE PROGRAMMING INDICATOR LED LIGHT TRANSPARENT EPO...

Page 20: ...e sensor Replace sensor Stops or water main closed Bad sensor to solenoid connection Debris or scale in solenoid assembly Remove solenoid pull out plunger and spring and clean with scale remover solut...

Page 21: ...age Replace servomotor seat Servomotor plate or diaphragm is obstructed Servomotor timer assembly is damaged Replace servomotor timer assembly Probable Cause Solution Valve riser tubing is crimped Str...

Page 22: ...corn Solid Surface Repair Kit is available Contact the factory for details Refer to drawing 9927 160 002 NORMAL CLEANING Clean weekly or more often as needed especially high polishing surfaces IF SPOT...

Page 23: ...current specifications 1 4 Lock Washer 0337 050 000 0331 005 000 1 4 Flat Washer COMPONENTS REPAIR PARTS Description Part No Diagram MOUNTING HARDWARE 1 4 20 UNC x 1 Hex Head Cap Screw 0206 002 000 0...

Page 24: ...s Part 9927 141 001 Page 24 of 28 PUSHBUTTONS COMBINED WASTE ASSEMBLY 1 4 20 Hex Nut Allen Head Bit With Center Reject 0296 025 199 4970 001 001 P trap Assembly Cover Plate 6214 150 001 Elbow Grid Str...

Page 25: ...specifications Description Corterra Plug Contact factory for color selection 6214 109 101 6213 129 000 Soap Filler Assembly 6214 004 001 Soap Tank Drain Adapater 6214 012 199 Soap Dispenser Assembly 6...

Page 26: ...5 001 2998 055 199 Spanner Key For Spout Aerator And Soap Filler 9 VDC Plug In Transformer 0711 410 001 9 VDC Solenoid 2563 326 001 ELECTRONIC HARDWARE COMPONENTS REPAIR PARTS Description Part No SPOU...

Page 27: ...COMPONENTS REPAIR PARTS Description Part No VALVE Diagram 2598 301 001 Optional 1 Station Hand Operated Single Temp Metering Valve Assembly 2598 231 001 Optional 2 Station 9VDC Solenoid Single Temp Va...

Page 28: ...iting to the company within reasonable period after receipt of the product Where claims for defects are made the defective part or parts shall be delivered to the company prepaid at City of Industry C...

Reviews: