A311.8 Series Compact Wall Mounted Water Cooler
INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
Please visit
for most current specifications.
www.acorndrinkingfountains.com
ACORN ENGINEERING FIELD SERVICE
TOLL FREE
800-743-8259 •
LOCAL
626-855-4866 •
FAX
626-855-4863
L1001051
Date: 06/15/15
Page 2 of 9
GENERAL NOTES:
1. ALL DIMENSIONS ARE IN INCHES [MM]
2. ALLOW 4 INCHES [102 MM] MINIMUM CLEARANCE PER SIDE FOR VENTILATION
*3. DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT. ADJUST VERTICAL
DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE, & LOCAL CODES.
4. STOP VALVE, TRAP, & ELECTRICAL OUTLET NOT SUPPLIED.
5. IMPORTANT: COOLER MUST BE ATTACHED TO WALL WITH ANCHOR SCREWS.
AIR FLOW
FINISHED FLOOR
C
L
1
3
8
"
6
7
8
"
TAIL
PIECE
22
3
8
"
*41
1
8
"
ANCHOR
CLIP
6
1
2
"
7
1
2
"
4"
4
1
2
"
2"
4"
18
7
8
"
5
7
8
"
7
1
2
"
22
3
8
"
3/8" SUPPLY
INLET
1-1/4"
WASTE
OUTLET
ELECTRIC
OUTLET
(2) 5/16"
OD HOLES
(2) 3/8"
OD HOLES
15"
6
3
4
"
IMPORTANT
This fixture is intended to dispense water that has been lowered in temperature, but otherwise remains
unchanged by the materials in the water cooler. It is common for electrical equipment to be grounded to water
lines either within a structure or away from it. Every attempt should be made to prevent this kind of grounding
from generating electrical feedback into the water cooler creating electrolysis. Electrolysis will cause a metallic
taste or cause water metal content to increase.
NOTICE
A dielectric coupling must be used to connect the water cooler to the water supply . A nonmetallic coupler is
furnished with this water cooler to meet this requirement.
ROUGHING-IN AND DIMENSIONAL DRAWING
Prior to roughing consult with local, state, and federal codes for proper mounting height.