background image

NOTE:

 See next page for table of part numbers corresponding to drawing above. 

 

COOLER PARTS BREAKDOWN DRAWING

 

     

 

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Please visit 
for most current specifications.

www.acorndrinkingfountains.com

1

11

4

6

7

9

16

17

18

20

21

22

23

9

24

25

26

15

13

12

19

8

5

3

2

10

14

28

27

15"

28 27

18"

28 27

18"

NOTE:

** Flow Restrictor Only Available

    With Low Flow Bubbler.

**  29

ACORN ENGINEERING FIELD SERVICE

TOLL FREE

 800-743-8259 • 

LOCAL

  626-855-4866 • 

FAX

 626-855-4863

L1001051

Date: 06/15/15

Page 8 of 9

Summary of Contents for A311108F

Page 1: ...s and does not apply to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the...

Page 2: ...61 2 71 2 4 41 2 2 4 187 8 57 8 71 2 223 8 3 8 SUPPLY INLET 1 1 4 WASTE OUTLET ELECTRIC OUTLET 2 5 16 OD HOLES 2 3 8 OD HOLES 15 63 4 IMPORTANT This fixture is intended to dispense water that has bee...

Page 3: ...es adjustment insert a slotted narrow blade screwdriver through the hole centered on the pushbutton to the flow regulator Turning clockwise will increase flow and turning counterclockwise will decreas...

Page 4: ...10 Fixture operates within water pressure range of 20 to 105 psig Acorn Engineering will not warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or higher th...

Page 5: ...All these signs indicate a problem within the refrigeration system and the water cooler must be checked by an authorized service company 4 Compressor Cycling On Overload Protector a A dirty condenser...

Page 6: ...g chrome plated items and mirror finished stainless steel They can scratch easily and should only be cleaned using a clean soft cloth and mild soap with water or a mild glass cleaner STANDARD CARTRIDG...

Page 7: ...on assembly prior to leaving the site to ensure there are no leaks DISCONNECTING THE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards...

Page 8: ...e visit for most current specifications www acorndrinkingfountains com 1 11 4 6 7 9 16 17 18 20 21 22 23 9 24 25 26 15 13 12 19 8 5 3 2 10 14 28 27 15 28 27 18 28 27 18 NOTE Flow Restrictor Only Avail...

Page 9: ...00 ALLEN PAN HEAD SCREW 11 7003 250 000 COLD CONTROL 12 7004 101 001 EVAPORATOR ASSEMBLY 13 7004 407 199 BACK PLATE 14 7004 408 199 HANGER BRACKET 15 7000 021 001 Y STRAINER 16 7000 032 001 DRAIN TUBE...