Diagnose *

 – Only for Lithium battery type, subjected to the Lithium battery initial voltage then determinegoing to

 Soft start or Bulk charge; if the Lithium battery is protected by BMS, the controller will automatically send the sign

al periodically to the battery terminal to activate the BMS against protection.

Soft start 

-

 

When batteries suffer an over-discharge, the controller will softly ramp the battery voltage upto 10V for

 12V battery, 20V for 24V battery.

Bulk Charge 

- Maximum current charging until batteries rise to Absorption level.

           For Lead crystal battery type, the charge controller will deliver two step level of Bulk charge, when the first 

level rises the battery voltage up to14.4V, then switch into the second level of the 50% of the first bulk charge rate

, until the Lead crystal battery voltage up to 14.7V. 

Absorption 

-

 

Constant voltage charging and battery is over 85% for lead acid battery; a Li-ion battery, LiFePO4

 battery and LTO battery will close fully charging after absorption stage, the absorption voltage level will reach 12

.6V for Li-ion battery, 14.4V for LiFePO4 battery; 14.0V for LTO battery. 14.7V for Lead crystal battery.

Equalization * 

- Only for WET battery or Calcium battery type, when the battery is deeply drained below 10V or 

every 28 days cycle, it will automatically run this stage to bring the internal cells as an equal state and fully comp

lement the loss of capacity. (Lead crystal, Li-ion, LiFePO4, LTO, Gel and AGM battery do not run Equalization ch

arge)

Float Charge or Re-Bulk charge 

- Battery is fully charged and maintained at a safe level.A fully charged Lead 

acid battery (Crystal, GEL, AGM, WET battery) has a voltage of more than 13.8 Volts;if the lead acid battery volta

ge drops to 12.8V at float mode, it will return to Bulk charge; Li-ion,LiFePO4 and LTO battery have no float mode; 

If a Li-ion battery voltage drops to 12.0V after absorption stage, it willreturn to Bulk charge; if a LIFePO4 battery 

voltage drops to 13.4V, or LTO battery voltage drops to 13.2V after Absorption stage, they will return to Bulk 

charge. (voltage x 2 for 24V use)

2.3 LED INDICATION

Voltage are for 12V use, x 2 for 24V use

Summary of Contents for HY-PTK-100WPX20A

Page 1: ...e 10 Anderson Plug 4 Aluminum support legs 11 Fuse 5 20A Solar charge controller 12 Handy carry bag 6 Junction box 13 Corner protector 7 Label 14 MC4 cables 8 Cable 14a Red Positive MC4 Cable 9 Batter...

Page 2: ...www ACOPower com 4120 Valley Blvd Walnut CA 91789 USA 1 626 737 1140 HY PTK 100WPX20A 5 Charge 12V battery by Lithium ion LiFePO4 LTO Gel AGM Flooded Crystal and Calcium batteries...

Page 3: ...www ACOPower com 4120 Valley Blvd Walnut CA 91789 USA 1 626 737 1140 HY PTK 100WPX20A 5 4...

Page 4: ...4120 Valley Blvd Walnut CA 91789 USA 1 626 737 1140 HY PTK 100WPX20A The solar panel kit is designed to charge a large range of batteries including Lithium ion LiFePO4 LTO Gel AGM Flooded Crystal and...

Page 5: ...81 22 3 2 3 03 1 Features and Mounting HY PTK 100WPX20A ProteusX 20A Charge Controller The ProteusX is ACOPOWER s first waterproof PWM charge controller It is a negative ground controller This ensure...

Page 6: ...tomatically me morize your battery type setting Li ion battery shown in LCD indicates 3 SERIES Li ion battery shown as below Lithium Cobalt Oxide LiCoO2 LCO battery Lithium Manganese Oxide LiMn2O4 LMQ...

Page 7: ...button in sequence the LCD will display in turn with Battery Voltage Charging Current Charged capacity Amp hour and Battery Temperature if external temperature sensor connected Display in sequence Al...

Page 8: ...O4 battery and LTO battery will close fully charging after absorption stage the absorption voltage level will reach 12 6V for Li ion battery 14 4V for LiFePO4 battery 14 0V for LTO battery 14 7V for L...

Page 9: ...ectrical Parameters 1 1 Rated solar panel amps 10 15 20 Max AMP 1 2 Normal input Solar cell array voltage 15 22 VDC 1 3 Max solar cell array voltage output has no load 25 Max VDC 1 4 The controller lo...

Page 10: ...ttery 13 2 0 2 VDC Restart voltage for LFP battery 13 4 0 2 VDC Restart voltage for Li ion battery 12 0 0 2 VDC 2 11 Voltage control accuracy 1 2 12 Battery temperature compensation coefficient 24 mV...

Page 11: ...alnut CA 91789 USA 1 626 737 1140 HY PTK 100WPX20A A There are 8 batteries can be used with it Lithium ion LiFePO4 LTO Gel AGM Flooded Crystal and Calcium batteries A Yes it is IP65 Waterproof for the...

Page 12: ...www ACOPower com 4120 Valley Blvd Walnut CA 91789 USA 1 626 737 1140 HY PTK 100WPX20A...

Page 13: ...www ACOPower com 4120 Valley Blvd Walnut CA 91789 USA 1 626 737 1140 Warranty Registration Web HY PTK 100WPX20A...

Reviews: