background image

09/2017  Subject to change without notice

9

Note: We recommend the ACO Stormbrixx seepage kit for infiltration of 
excessive rainwater

Application example

ACO roof gutter mesh

ACO Rain4me 

rainwater harvesting

ACO Stormbrixx seepage kit

(SUDS) infiltration system

ACO sludge trap

(required for House and Garden 

Compact and Professional)

The piping from the tank to the sludge trap 
and on to the Stormbrixx must be laid with 
at least the same pipe diameter as the 
inlet pipes to the tank and with at least 2° 
gradient.

ACO Severin Ahlmann
GmbH & Co. KG

P.O. Box 320, 24755 Rendsburg
Am Ahlmannkai, 24782 Büdelsdorf
Germany
Phone +49 4331 354-0
[email protected]

www.aco.com
www.rain4me.aco

Summary of Contents for Rain4me

Page 1: ...rk must be carried out according to DIN 18300 DIN 4124 EN 1610 and the DWA A 139 and ATV DVWK A 127 standards Accessing the tank without appropriate soil cover is not planned and should be avoided sho...

Page 2: ...points Technical Data Tank Art No Weight kg L mm W mm H mm Material Basic 103000 approx 105 2230 1230 855 PE LLD Extension 103002 approx 105 2230 1230 855 PE LLD production related dimensional differ...

Page 3: ...with the values required in the installation instructions to deter mine whether it is suitable it is possible for the functional capability of the system or the tank connections to be impaired and th...

Page 4: ...one free approx 100 150 mm thick is laid and compacted as the subbase blinding layer 5 2 1 Hillside location slope etc If the tank is installed in the immediate vicinity 5 00 m of a hill hillside or s...

Page 5: ...utside the tanks by assembling straight pipe lengths and bends in the corners 1 x 90 87 2 x 45 or 3 x 30 for installation of the seals pipes see sketch above V 2 Lying installation possible extension...

Page 6: ...ow webs here slurrying must be used 5 5 Laying the connections The inlet pipe from the house to the tank must be laid with a gradient of at least 1 in the direction of flow the overflow pipe from the...

Page 7: ...rews can be removed and screwed back in on the inside of the dome to secure its position After backfilling the soil the screws should be removed again to prevent possible risk of injury in the dome ac...

Page 8: ...the joint between the plastic dome and the concrete frame not included in the scope of supply 6 4 Integral tank filter If an integral tank filter is used and it is not preinstalled it must be install...

Page 9: ...the cable from the float switch of the drinking water topup from the under ground tank to the service connection room in the house IMPORTANT Now plug the intermediate connector of the float switch in...

Page 10: ...nstallation Garden use only Inlet Overflow House garden use Blank pipe for hoses cable Overflow Opening must be closed Garden use only House garden use Inlet Opening must be closed Overflow Overflow W...

Page 11: ...check of the ventilation air supply and removal Compare the level in the store with the level indicator Check the visible pipes and cables for condition leaktightness fixing and corrosion Check the w...

Page 12: ...filtration system ACO sludge trap required for House and Garden Compact and Professional The piping from the tank to the sludge trap and on to the Stormbrixx must be laid with at least the same pipe d...

Reviews: