TWO & MORE CDNP OUTSIDE UNITS WIRING DIAGRAM
INSIDE UNIT INSTALLATION & WIRING
Install the inside units as specified in their original manuals. Wire the equipment while setting the
proper address in the inside unit decoder; wire the outside unit LINE terminals with proper polarity.
VOLUME SETTING
Set the volume as follows once the inside unit is connected properly:
–
MIC
potentiometer sets the sensitivity of the outside unit microphone
–
SOUNDS
potentiometer sets the outside unit sound output volume
-
SPK
potentiometer sets the outside unit speaker volume
Having set the values, operate the
BALANCE
potentiometer to find the points of
excitation of the outside unit speaker (indicated by its squeak); next, adjust the
potentiometer halfway between these points.
OPERATION
When in standby, the display shows the “Intro” message (which reads “
aco
” by default). The “Intro”
message contents are freely configurable. The default range of dialled numbers is 1 to 255, with
each value mapped directly to the physical addresses configured in the inside units (the software
configuration tool permits any dialled number range between 0 and 999999 and a free assignment
of each number to the inside unit address, or to restrict the range of supported inside units). Dialling
is done by inputting the apartment number with the keypad; if the optional 230E module is installed,
select the apartment number entry with the arrow buttons, followed pressing the Doorbell button.
After approx. 3 s, the inside unit in the dialled apartment starts ringing. If the dialled call is received
in the dialling mode, a voice conversation is possible with unlocking the door electric strike. Opening
the door electric strike by inputting an apartment code: input the apartment number, confirm with the
Key button and follow with the 4-digit access code mapped to the input apartment number. In order
to print the full table of user codes or ready business cards for tenants together with the instructions
for use, use the "ACO Code Generator" available at
in the user area ("download").
For each "Master" control panel, the code table is factory-set on the back of the device as a 4-digit
number, and for "Slave" devices, enter the same table as in "Master". Opening the door electric strike
with one of the five building administrator access codes: press the Key button and follow by inputting
the six-digit code. The building administrator access codes are intended for use by building
administration and maintenance personnel, e.g. maintenance technicians, the janitor, postmen, etc.
The wired door electric strike can also be unlocked by shorting the additional
INPUT
to ground. If a
proximity reader (ACC) is wired, the door electric strike is unlocked with the proximity card or keyfob
(paired with the outside unit and issued to e.g. the tenants, the building administration staff, or the
(mic)
(sound)
(bal)
(spk)