TWO & MORE CDNP OUTSIDE UNITS WIRING DIAGRAM 

 

INSIDE UNIT INSTALLATION & WIRING

 

Install the inside units as specified in their original manuals. Wire the equipment while setting the 
proper address in the inside unit decoder; wire the outside unit LINE terminals with proper polarity.

 

 

VOLUME SETTING 

Set the volume as follows once the inside unit is connected properly:

 

 

MIC

 potentiometer sets the sensitivity of the outside unit microphone

 

 

SOUNDS

 potentiometer sets the outside unit sound output volume

 

-   

SPK

 potentiometer sets the outside unit speaker volume

 

Having  set  the  values,  operate  the 

BALANCE

  potentiometer  to  find  the  points  of 

excitation  of  the  outside  unit  speaker  (indicated  by  its  squeak);  next,  adjust  the 
potentiometer halfway between these points.

 

 

OPERATION

 

When in standby, the display shows the “Intro” message (which reads “

aco

” by default). The “Intro” 

message contents are freely configurable. The default range of dialled numbers is 1 to 255, with 
each value mapped directly to the physical addresses configured in the inside units (the software 
configuration tool permits any dialled number range between 0 and 999999 and a free assignment 
of each number to the inside unit address, or to restrict the range of supported inside units). Dialling 
is done by inputting the apartment number with the keypad; if the optional 230E module is installed, 
select the apartment number entry with the arrow buttons, followed pressing the Doorbell button. 
After approx. 3 s, the inside unit in the dialled apartment starts ringing. If the dialled call is received 
in the dialling mode, a voice conversation is possible with unlocking the door electric strike. Opening 
the door electric strike by inputting an apartment code: input the apartment number, confirm with the 
Key button and follow with the 4-digit access code mapped to the input apartment number. In order 
to print the full table of user codes or ready business cards for tenants together with the instructions 
for use, use the "ACO Code Generator" available a

www.aco.com.pl

 in the user area ("download"). 

For each "Master" control panel, the code table is factory-set on the back of the device as a 4-digit 
number, and for "Slave" devices, enter the same table as in "Master". Opening the door electric strike 
with one of the five building administrator access codes: press the Key button and follow by inputting 
the  six-digit  code.  The  building  administrator  access  codes  are  intended  for  use  by  building 
administration and maintenance personnel, e.g. maintenance technicians, the janitor, postmen, etc. 
The wired door electric strike can also be unlocked by shorting the additional 

INPUT

 to ground. If a 

proximity reader (ACC) is wired, the door electric strike is unlocked with the proximity card or keyfob 
(paired with the outside unit and issued to e.g. the tenants, the building administration staff, or the 

(mic) 

(sound) 

(bal) 
(spk) 