background image

STEP 2

CHECK DIRECTION

Press UP or DOWN buttons and ensure blind is moving in correct direction.

If working correctly proceed to Step 3.

Press and release buttons.

UP/DOWN

TO CORRECT BLIND DIRECTION

Press button on motor head for 5 seconds to change orientation of blind. 

 

Motor beeps & jolts to confirm change of direction.

Check blind direction again before proceeding to Step 3.

For instructional purposes, the following options have been shown:

 Easy-Lock Chain Winder 'AC' Installation Brackets.

 Top Fix installation.
 'AC' Bracket Cover Caps
 40mm Motor - Somfy.

 Somfy Drive & Crown Wheels.

INSTALLATION

ROLLER BLINDS                                    

40mm MOTORISATION

ENSURE 'NOTCH' OF CROWN WHEEL 

LOCKS WITHIN GAP OF MOTOR HEAD. 

ASSEMBLY INSTRUCTIONS
STEP 1:

 Install 

Crown Wheel 

onto

40mm Motor

. Ensure 'notch' of 

Crown

   Wheel

 locks within gap of 

Motor Head

.

STEP 2:

 Install 

Drive Wheel

 onto

 40mm Motor

.

   NOTE: 

   * For Elero Motors, use 'O' ring supplied by Elero to lock 

Drive Wheel 

to

 40mm Motor

.

   * For Gaposa Motors, use 

Gaposa Retaining Clip

 to lock 

Drive Wheel

      to

 40mm Motor

.

   * For Selve Motors, use plastic retaining clip supplied by Selve to lock 

Drive Wheel

 to 

40mm Motor

.

STEP 3:

 Mount 

40mm Motor Disk Adaptor

 onto 

Motor head

 with 

Counter

   Sunk Screws

.

ONLY USE WITH GAPOSA

Page 57

P2 (x1)

UP (x1)

P2 (x1)

a. Set desired upper limit position, using the UP button.

    Press DOWN to readjust blind to desired position.

b. When a more accurate setting is required put motor in 
     stepping mode by pressing UP+STOP at the same time while 

     motor is moving UP/DOWN

c. Once blind is at desired position press STOP for 5 seconds until motor jolts.

    Motor will jolt to confirm limit.

UP/DOWN

STOP 

(for 5 secs)

UP/DOWN

STOP 

(for 5 secs)

Refer Page 3 for instructions.

P2 (x1)

P2 (x1)

DOWN (x1)

P2 (x1)

P2 (x1)

STOP (x1)

Page. 4

a. Press P2 button once
b. Press UP button once
c. Press P2 button once

STEP 3

PUT MOTOR IN LIMIT SETTING MODE

STEP 4

SET UPPER LIMIT

a. Set desired lower limit position using the DOWN button.

    Press UP to readjust blind to desired position.

b. When a more accurate setting is required put motor in 
     stepping mode by pressing UP+STOP at the same time 

     while motor is moving UP/DOWN

c. Once blind is at desired position, press STOP for 5 seconds until motor jolts.

    Motor will jolt to confirm limit.

STEP 5

SET LOWER LIMIT 

C A N C E L   L I M I T S

R E T U R N   T O   F A C T O R Y   S E T T I N G S

a. Press P2 button once
b. Press DOWN button once
c. Press P2 button once

a. Press P2 button once
b. Press STOP button once
c. Press P2 button once

FOR AUTOMATE Q S45 & S60 MOTOR ONLY

S E T   F A V O U R I T E   P O S I T I O N

Summary of Contents for RF400 Series

Page 1: ...onic limit tubular motors Automate EL S45 Automate Q EL S45 quiet motor Automate EL S60 with collision control technology Automate EL A50 for open awnings Automate EL A50 C for cassette awnings Automate C EL Curtain motor These motors can be controlled with Automate RF 400 series remote devices Automate RF401 single channel Automate RF415 15 channel RF400 series Remote Control 1 2 3 AC 1 2 3 1 2 3...

Page 2: ...ng in correct direction If working correctly proceed to Step 3 Press and release buttons UP DOWN TO CORRECT BLIND DIRECTION Press button on motor head for 5 seconds to change orientation of blind Motor beeps jolts to confirm change of direction Check blind direction again before proceeding to Step 3 a Press UP STOP buttons at the same time b Press UP button once c Press UP STOP buttons at the same...

Page 3: ...O R Y S E T T I N G S a Press UP STOP at the same time and release b Press DOWN button once c Press UP STOP at the same time and release UP STOP DOWN x1 UP STOP a Press UP STOP at the same time and release b Press STOP button once c Press UP STOP at the same time and release UP STOP STOP x1 UP STOP PROGRAMMING A 15 CHANNEL WALL MOUNTED REMOTE IN 5 SIMPLE STEPS BEFORE YOU BEGIN PLACE CR2450 3V BATT...

Page 4: ... confirm limit UP DOWN STOP for 5 secs UP DOWN STOP for 5 secs Refer Page 3 for instructions P2 x1 P2 x1 DOWN x1 P2 x1 P2 x1 STOP x1 Page 4 a Press P2 button once b Press UP button once c Press P2 button once STEP 3 PUT MOTOR IN LIMIT SETTING MODE STEP 4 SET UPPER LIMIT a Set desired lower limit position using the DOWN button Press UP to readjust blind to desired position b When a more accurate se...