ACME XP-1000WZ User Manual Download Page 3

  1. Safety Instruction   

 

 

WARNING   

Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that 
they also receive this instruction manual. 

Important: 
Damages caused by the disregard of this user manual are not subject to warranty. The dealer 
will not accept liability for any resulting defects or problems

 

Unpack and check carefully that there is no transportation damage before using the unit. 

 

The unit is for indoor use only. Use only in a dry location. 

 

Do install and operate by qualified operator. 

 

Do not allow children to operate the fixture. 

 

Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head only. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent 
surfaces.   

 

Be sure that no ventilation slots are blocked; otherwise the unit will be overheated. 

 

Before operating, ensure that the voltage and frequency of power supply matches the power 
requirements of the unit. 

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

Maximum ambient temperature TA: 40

. Don’t operate it when the temperature is higher. 

 

Don’t connect the device to any dimmer pack. 

 

During initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective, and it will decrease gradually within 15 minutes. 

 

Make sure there are no flammable materials close to the unit while operating to avoid fire hazard. 

 

Examine the power wires carefully; replace them immediately if there is any damage. 

 

Unit’s surface temperature may reach up to 85

. Don’t touch the housing bare-handed during its 

operation, and allow about 15 minutes for cooling the unit down before replacing bulb or 
maintenance as it could be very hot. 

 

Avoid any inflammable liquids, water or metal objects entering the unit. Once it happens, cut off 
the mains power immediately. 

Please read the instruction manual carefully which includes important 

information about the installation, usage and maintenance. 

 

Summary of Contents for XP-1000WZ

Page 1: ...XP 1000WZ User Manual Please read the instruction carefully before use...

Page 2: ...The Lamp 7 5 How To Set The Unit 8 5 1 Main Function 8 5 2 Home Position Adjustment 16 5 3 Error Information 19 6 Control By Universal DMX Controller 20 6 1 DMX Connections 20 6 2 Channel Mode Settin...

Page 3: ...f power supply matches the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperature TA 40 Don t operate...

Page 4: ...to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center if needed Disconnect the main...

Page 5: ...maintenance by magnetic home positioning Pan Tilt position lock for transporting protection Dimmer Shutter Mechanical dimmer Mechanical shutter and adjustable speed strobe effect Color wheel Color wh...

Page 6: ...arious menus and the selected functions 2 BUTTON MENU To select the programming functions To go backward in the selected functions To go forward in the selected functions ENTER To confirm the selected...

Page 7: ...C250V T 15A Protect the unit from damage of over voltage or short circuit 12 POWER Connect to the mains supply 4 Lamp 4 1 Lamp OSRAM 1 Because of its high internal pressure there might be a risk that...

Page 8: ...e shielding 5 When ling up the lamp operates at high pressure and there is a slight risk of arc tube rupture The risk increases with age temperature and improper handling of the lamp Do not use the la...

Page 9: ...he unit press the MENU button into menu mode and press the UP DOWN button until the required function is shown on the monitor Select the function by the ENTER button Use the UP DOWN button to choose t...

Page 10: ...A 9...

Page 11: ...w DMX Value or Wireless DMX Reset DMX Address To select DMX Address press the ENTER button to confirm Use the UP DOWN button to adjust the address from 1 to 512 press the ENTER button to store Press t...

Page 12: ...again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Art net Setting To select Art net Setting press the ENTER button to confirm Use the UP DOWN button t...

Page 13: ...Feedback press the ENTER button to confirm Use the UP DOWN button to select No Pan or tilt s position will not feedback while out of step or Yes Feedback while pan tilt out of step press the ENTER but...

Page 14: ...s Linear The increase in light intensity appears to be linear as DMX value is increased S cure Light intensity control is finger at low levels and high levels and coarser at medium levels Lamp Setting...

Page 15: ...press the ENTER button to confirm Use the UP DOWN button to adjust the value from 1 to 10 press the ENTER button to store Press the MENU button back to the last menu or let the unit idle one minute t...

Page 16: ...he UP DOWN button to select Fixture Use Hour Light Use Hour Temperature Fan State or Firmware Version Fixture Use Hour Select Fixture Use Hour press the ENTER button to confirm fixture use time will s...

Page 17: ...set shutter to their home positions or No and press the ENTER button to store Press the MENU button to exit All Reset All To select All press the ENTER button to confirm use the UP DOWN button to sele...

Page 18: ...ncoder Calibrate press the ENTER button to confirm Use the UP DOWN button to offset the Encoder Calibrate press the ENTER button to store Press the MENU button to exit Pan pan home position adjustment...

Page 19: ...to store Press the MENU button to exit Color 2 Gobo1 home position adjustment Enter offset mode select Color 2 press the ENTER button to confirm Use the UP DOWN button to offset the value from 128 to...

Page 20: ...Press the MENU button to exit 5 3 Error Information Lamp Startup Fail It appears when there is no lamp or some wires are damaged Temperature Sense Error It appears when temperature check board is dam...

Page 21: ...trol By Universal DMX Controller 6 1 DMX Connections 1 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR...

Page 22: ...o select 26 Channel 34 Channel 28 Channel 24 Channel or 21 Channel Mode and press the ENTER button to store Press the MENU button back to the last menu or let the unit idle one minute to exit menu mod...

Page 23: ...to low power Shutter Open Strobe slow fast Shutter Open Random strobe 7 0 255 DIMMER Closed 0 Open 100 8 0 001 014 015 016 029 030 031 044 045 046 059 060 061 074 075 076 089 090 091 104 105 140 141...

Page 24: ...55 156 160 161 165 166 170 171 185 186 211 212 217 218 243 244 247 248 251 252 255 COLOR 2 Open Open to Color 1 Color 1 Color 1 Color 2 Color 2 Color 2 Color 3 Color 3 Color 3 Color 4 Color 4 Color 4...

Page 25: ...079 080 089 090 099 100 109 110 129 130 139 140 149 150 159 160 169 170 189 190 199 200 209 210 229 230 239 240 255 FUNCTION No Function Enable Blackout X Y Move Disable Blackout X Y Move Enable Black...

Page 26: ...pen Lamp Off 2 0 255 DIMMER Closed 0 Open 100 3 0 255 CYAN 0 100 4 0 255 MAGENTA 0 100 5 0 255 YELLOW 0 100 6 0 255 CTO 3200K 0 100 7 000 128 129 160 161 165 166 170 171 175 176 180 181 185 186 214 21...

Page 27: ...10 Null 11 Null 12 Null 13 Null 14 Null 15 Null 16 0 255 PAN 0 540 17 0 255 PAN FINE 18 0 255 TILT 0 270 19 0 255 TILT FINE 20 0 255 PAN TILT SPEED Fast Slow 21 Null 21 Channels Mode 3 CHANNEL VALUE...

Page 28: ...All No Function Lamp Off No Function 7 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 063 064 071 072 079 080 087 088 095 096 103 104 111 112 119 120 127 128 135 136 143 144 151 152 159...

Page 29: ...r 1 Color 1 Color 1 Color 2 Color 2 Color 2 Color 3 Color 3 Color 3 Color 4 Color 4 Color 4 Color 5 Color 5 Color 5 Color 6 Color 6 Color 6 Open Open Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Op...

Page 30: ...ndom color Fast Random color Medium Random color Slow 11 0 255 CYAN 0 100 12 0 255 MAGENTA 0 100 13 0 255 YELLOW 0 100 14 0 255 CTO 3200K 0 100 15 000 021 022 042 043 063 064 085 086 106 107 127 128 1...

Page 31: ...problems that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connect power and main fuse 2 Measur...

Page 32: ...ng well Check the mains voltage either too high or too low 2 Internal temperature may be too high Check if replacement of fan is needed on the head E If The pan belt is broken 1 Turn off the mains pow...

Page 33: ...nd Maintenance Schedule Check Ballast A Do check the fixtures every two months and make sure that all the screws and terminals have been locked firmly to make sure the normal performance of the fixtur...

Page 34: ...fully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Maintenance Schedule To make sure that the fixture is running well and has less failures and...

Page 35: ...Code R Replace C Clean L Lubricate A Adjust A 34...

Page 36: ...f the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 E...

Reviews: