ACME XA-500 User Manual Download Page 7

 
 

DMX Settings 

To select 

DMX Settings

 press the ENTER button to confirm, use the UP/DOWN button to select 

DMX Address

 or

 Channel Mod. 

DMX Address —DMX512 address setting 

To select  DMX Address, press the  ENTER  button to confirm.  Use  the  UP/DOWN  button to 

adjust the address from 001 to 512, press the ENTER button to store. Press the MENU button 

back to the last menu or let the unit idle one minute to exit menu mode. 

DMX Channel Mode 

To select DMX Channel Mode, press the ENTER button to confirm. Use the UP/DOWN button 

to select 20 CH or 31 CH, press the ENTER button to store. Press the MENU button back to the 

last menu or let the unit idle one minute to exit menu mode 

 

Fixture Settings 

To select 

Fixture Settings

, press the ENTER button to confirm, use the UP/DOWN button to select 

Pan Inverse, Tile Inverse, P/T Feedback

Focus Compensate

 

BL.O. P/T Moving, BL.O. Color 

Change,

 

BL.O. Gobo Change

Dimmer Speed

 or

 Dimmer Curve. 

Pan Inverse 

To select Pan Inverse, press the ENTER button to confirm. Use the UP/DOWN button to select 

No  (normal) or Yes  (pan inverse), press the ENTER  button to store. Press the  MENU  button 

back to the last menu or let the unit idle one minute to exit menu mode. 

Tilt Inverse 

To select Tilt Inverse, press the ENTER button to confirm. Use the UP/DOWN button to select 

No (normal) or Yes (tilt inverse), press the ENTER button to store. Press the MENU button back 

to the last menu or let the unit idle one minute to exit menu mode. 

P/T Feedback   

To select  P/T Feedback, press the  ENTER  button to confirm.  Use the  UP/DOWN  button  to 

select  No  (Pan or tilt’s position will not feedback while out of step) or Yes  (Feedback while 

pan/tilt out of step), press the ENTER button to store. Press the MENU button back to the last 

menu or let the unit idle one minute to exit menu mode. 

Focus Compensate 

To select Focus Compensate, press the ENTER button to confirm. Use the UP/DOWN button 

 

6A 

Summary of Contents for XA-500

Page 1: ...XA 500 FRAMING User Manual Please read the instruction carefully before use...

Page 2: ...3 3 How To Set The Unit 4 3 1 Control panel 4 3 2 Main Function 4 3 3 Home Position Adjustment 10 4 Control By Universal DMX Controller 12 4 1 DMX Connection 12 4 2 Address Setting 13 4 3 DMX 512 Con...

Page 3: ...fire hazard Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base Maximum ambient temperature is Ta 40 DO NOT operate it where the temperat...

Page 4: ...while operating And make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can...

Page 5: ...WITCH Turn on off the power 6 FUSE T15Amp Protect the unit from damage of the overcurrent 3 2 Main Function To select any of the given functions press the MENU button up to when the required one is sh...

Page 6: ...12 No No No Display Setting Reset Functions 1 Yes Yes Yes No Yes 1 10 Special Functions Fixture Settings Fixture Information Fixture Test No Yes 29 CH 31 CH Square Law Inv SQ Law Liner S Curve No Yes...

Page 7: ...O P T Moving BL O Color Change BL O Gobo Change Dimmer Speed or Dimmer Curve Pan Inverse To select Pan Inverse press the ENTER button to confirm Use the UP DOWN button to select No normal or Yes pan i...

Page 8: ...ackout while change color press the ENTER button to store Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode BL O Gobo Change Blackout while change gobo To s...

Page 9: ...utton back to the last menu or let the unit idle one minute to exit menu mode Backlight Auto Off Select Backlight Auto Off press the ENTER button to confirm present mode will blink on the display use...

Page 10: ...re the fixture will run as the channel value indicates Press the MENU button back to the last menu or exit menu mode idling one minute All channels value will become 0 after exiting Manual Test menu F...

Page 11: ...one minute to exit menu mode All Reset All Select All press the ENTER button to confirm use the UP DOWN button to select Yes the unit will run built in program to reset all motors to their home posit...

Page 12: ...11A...

Page 13: ...re pass through to maintain the DMX circuit when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm...

Page 14: ...to adjust the address from 0 to 512 press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 7 seconds to exit menu mode Please refer to the following diagram...

Page 15: ...07 108 118 119 127 128 189 190 193 194 255 Gobo 1 Open Gobo1 Gobo2 Gobo3 Gobo4 Gobo5 Gobo6 Gobo1 Shaking Gobo2 Shaking Gobo3 Shaking Gobo4 Shaking Gobo5 Shaking Gobo6 Shaking Rotation Fast Slow Stop R...

Page 16: ...ism No Effect Prism 1 Prism 2 14 000 127 128 189 190 193 194 255 R Prism Index 0 360 Rotation Fast Slow Stop Rotation Slow Fast 15 000 255 Zoom 0 100 16 000 255 Focus 0 100 17 000 007 008 015 016 131...

Page 17: ...55 FRAMING 7 0 100 28 000 255 FRAMING 8 0 100 29 000 009 010 014 015 029 030 034 035 255 Function Null Reset All Reset Effect Reset Pan Tilt Null 31 Channels Mode Mode 2 CHANNEL VALUE FUNCTION 1 000 2...

Page 18: ...18 019 027 028 036 037 045 046 054 055 063 064 074 075 085 086 096 097 107 108 118 119 127 128 189 190 193 194 255 Gobo 1 Open Gobo1 Gobo2 Gobo3 Gobo4 Gobo5 Gobo6 Gobo1 Shaking Gobo2 Shaking Gobo3 Sha...

Page 19: ...ation Fast Slow Stop Rotation Slow Fast 14 000 255 Iris 0 100 15 000 007 008 127 128 255 Prism No Effect Prism 1 Prism 2 16 000 127 128 189 190 193 194 255 R Prism Index 0 360 Rotation Fast Slow Stop...

Page 20: ...7 0 100 30 000 255 FRAMING 8 0 100 31 000 009 010 014 015 029 030 034 035 255 Function Null Reset All Reset Effect Reset Pan Tilt Null 5 Troubleshooting Following are a few common problems that may o...

Page 21: ...it C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 6 Fixture Clea...

Page 22: ...21A...

Page 23: ...cordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 A1 2012 EN55103 2 2009 EN61000 3 2 2014 EN61000 3 3 2013 Harmonized Standard EN 60598 1 2015 EN...

Page 24: ...Innovation Quality Performance...