ACME VQL100 Instructions Manual Download Page 22

MODELS   VQL2000 • VQL3500  

Page 6

ACME ENGINEERING & MANUFACTURING CORP.

P.O. Box 978
Muskogee, Oklahoma 74402

SCHEMA DE L’INSTALLATION

CONFIGURATIONS 

POSSIBLES

CONVERSION ANGLE DROIT - EN LIGNE

Retirer at inverser la position des brides de conduits

et du panneau d’accès  sur le boîtier.

Pour les dimensions correctes des conduits d’admission d’air et 

d’echappement, voir le tableau 1.

TABLEAU 1

PANNEAU

D’ACCÉS

BRIDE DU CONDUIT 

D’ECHAPPEMENT

BRIDE DU

CONDUIT

D’ECHAPPEMENT

Configuration standard avec tige filetée enfilée à travers 

les voies de montage sur le dessus du boîter

TIGE FILETÉE DE 9, 5

mm MIN.

(autes fabricants)

 

DIM. VQL2000  VQL3500

  C 

43 cm 

43 cm

  D  100,6 cm  120,3 cm

Configuration avec tige filetée à travers les supports ré

-

glables situés sur le dessus du boîtier

TIGE FILETÉE DE 9,5 mm MIN.

(autes fabricants)

 

DIM. VQL2000  VQL3500

  A  19,6 cm 

26 cm”

  B  85.7 cm 

106 cm

Configuration avec tige filetée enfilée à travers les sup

-

ports réglabes situées en dessous de boîter

Les supports peuvent être boulonnés aux extrémités du boîter 

dans plusieurs positions. Utiliser les vis et les écrous fournis dans 

le sachet de visserie.

Sil l’appareil est installé au plafond, s’assurer que les brides de 

conduits ou le boîter se trouvent contre le plafond fini. Les brides 

de conduits peuvent être retirées et jetées si elles interfèrent avec 

l’installation du plafond.

CONFIGURATIONS 

POSSIBLES

 

MODÉLE 

DIMENSIONS DU 

DIMENSIONS DU

  

CONDUIT  

DU CONDUIT

  

D’ADMISSION 

D’ÉCHAPPEMENT

  VQL2000 

31,4 cm x 90,8 cm 

19,6 cm x 85,7 cm

  VQL3500 

36,8 cm x 110,5 cm 

24,7 cm x 113,6 cm

Fournir un support solude pour minimiser le bruit. II existe deux 

méthodes des montage standard pour ces appareils.

MODÈLES

BRIDES DES CONDUITS 

D’ADMISSION D’AIR

Summary of Contents for VQL100

Page 1: ...iling do not damage electri cal wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be insta...

Page 2: ...INISHED CEILING MATERIAL CEILING JOIST 16 centers shown 2 X 4 FRAMING wide side down MOUNTING BRACKETS Attached to opposite sides of housing upside down DUCTING Horizontal blower discharge Two ways to...

Page 3: ...arallel to joists New or existing construction BLOWER DISCHARGE POSITIONS WIRING PLATE POSITION Wiring plate mounts to side or top of housing HORIZONTAL POWER CABLE CONNECTION VERTICAL POWER CABLE CON...

Page 4: ...ICULAR PURPOSE WHICH ARE HEREBY EXPRESSLY DISCLAIMED AND WAIVED THIS WARRANTY CONSTITUTES THE COMPANYS SOLE AND EXCLUSIVE WARRANTY FOR DEFECTIVE GOODS AND PURCHASERS SOLE AND EXCLUSIVE REMEDY FOR DEFE...

Page 5: ...o not damage electri cal wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed ov...

Page 6: ...SHED CEILING MATERIAL CEILING JOIST 24 centers shown 2 X 4 FRAMING wide side down MOUNTING BRACKETS Attached to opposite sides of housing upside down so housing is flush with finished ceiling DUCTING...

Page 7: ...R CABLE CONNECTION VERTICAL POWER CABLE CONNECTION Blower and duct connector in straight through dis charge position Factory shipped DUCT CONNECTOR Blower and duct connector in right angle discharge p...

Page 8: ...WHICH ARE HEREBY EXPRESSLY DISCLAIMED AND WAIVED THIS WARRANTY CONSTITUTES THE COMPANYS SOLE AND EXCLUSIVE WARRANTY FOR DEFECTIVE GOODS AND PURCHASERS SOLE AND EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCTS...

Page 9: ...damage electri cal wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a t...

Page 10: ...discharge Two ways to connect ductwork to a factory shipped unit Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes ROOF CAP 12 ROUND ELBOW 12 ROUND DUC...

Page 11: ...lectric shock disconnect from power supply before servicing To clean blower assembly Remove access panel unplug blower from housing remove blower mounting nuts and carefully remove blower from housing...

Page 12: ...tion and do not express or imply any warranty WARNING product it determines to be defective and it shall ship the repaired or replacement product to Purchaser F O B point of shipment provided however...

Page 13: ...un mur ou un plafond prenez soin de ne pas endommager les fils lectriques et les autres utilit s dissimul es 6 La d charge des ventilateurs conduit par l event doit toujours se faire l ext rieur 7 Pou...

Page 14: ...E DE 12 po 30 5 cm sortie TRANSITIONS DE 8 x 12 po au 12 po circulaire 20 3 x 30 5 cm circulaire PANNEAU D ACCESS VIS DE PANNEAU D ACCESS Soufflerie pr assembl e en position de d charge de soufflerie...

Page 15: ...eur appropri ou retirer la grille et nettoyer l aide d un chiffon doux et de savon ou de d tergent doux pour nettoyer la zone de d charge de la soufflerie et la roue NE PAS LAISSER D EAU S INFILTRER D...

Page 16: ...oy agent revendeur ou autre personne n est autoris offrir la moindre garantie au nom de la soci t ou assumer la moindre responsabilit suppl mentaire pour la soci t en relation avec un produit quelconq...

Page 17: ...s such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration andAir Conditioning Engineers ASHRAE and the local code authorities 5 When...

Page 18: ...e mounting brackets located at top of housing 3 8 MIN THREADED RODS By Others DIM VQL2000 VQL3500 A 7 3 4 10 1 4 B 33 3 4 41 3 4 Mounting with threaded rods through adjustable mounting brackets locate...

Page 19: ...nd the National Electrical Code MOUNTING OPTIONS EXHAUST ACCESS PANEL INTAKE SLEEPER 1 1 4 Typical wall mounting with 3 8 threaded fasteners by others through mounting brackets Connect electrical powe...

Page 20: ...Company shall pass through to Purchaser such manufacturers warranty THE COMPANYS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED ARISING BY LAW OR OTHERWISE INCLUD ING WITHOUT LIMITATIO...

Page 21: ...ociation NFPA et l American society for Heating Refrigeration andAir Condition ing Engineers ASHRAE et des autorit s du code local 5 Lors de la coupe ou du percage dans un mur ou un plafond prenez soi...

Page 22: ...s du bo tier TIGE FILET E DE 9 5 mm MIN autes fabricants DIM VQL2000 VQL3500 A 19 6 cm 26 cm B 85 7 cm 106 cm Configuration avec tige filet e enfil e travers les sup ports r glabes situ es en dessous...

Page 23: ...OSSIBLES CHAPPEMENT PANNEAU D ACC d ADMISSION D AIR TRAVERSE 3 1 cm Montage mural standard avec attaches filet es de 9 mm autres fabricants enfil es travers les supports Brancher le c ble d alimentati...

Page 24: ...S PAR LA LOI OU NON Y COMPRIS MAIS SANS S Y LIMITER LES GARANTIES IMPLICITES RELATIVES LA QUALIT MARCHANDE ET L APTITUDE UNE UTILISATION PARTICULI RE QUI SONT EXPRESS MENT REJET ES ET D ROG ES LA PR S...

Reviews: