background image

9D 

6. How

 

To

 

Control

 

The

 

Fixture

Please

 

operate

 

the

 

fixture

 

by

 

VD

T

 

(sold

 

separately).

 

VD

T

 

is

 

a

 

specially

 

designed

 

handy

 

setup

 

tool

 

for

 

all

 

Visio

 

integral

 

fixtures

 

and

 

controllers.

 

By

 

connecting

 

VD

T

 

to

 

any

 

fixture

 

via

 

XLR,

 

you

 

can

 

easily

 

setup

 

DMX

 

Address,

 

Channel

 

Modes,

 

White

 

Balance,

 

Manual

 

Colors,

 

and

 

Fade

 

Speed

 

functions.

 

If

 

you

 

use

 

VD

T

 

to

 

control

 

the

 

fixture,

 

you

 

can

 

follow

 

User

 

Manual

 

of

 

VD

T.

   

7. DMX512

 

Configuration

2D 

1. Safety

 

Instructions

WARNING

   

Please

 

keep

 

this

 

User

 

Guide

 

for

 

future

 

consultation.

 

If

 

you

 

sell

 

the

 

fixture

 

to

 

another

 

user,

 

be

 

sure

 

that

 

they

 

also

 

receive

 

this

 

instruction

 

booklet.

 

Cautions

 

All

 

fixtures

 

are

 

intact

 

from

 

the

 

manufacturer,

 

please

 

operate

 

follow

 

up

 

the

 

user

 

manual,

artificial

 

fault

 

are

 

not

 

under

 

guarantee

 

repair.

 

Unpack

 

and

 

check

 

carefully

 

there

 

is

 

no

 

transportation

 

damage

 

before

 

using

 

the

 

fixture.

Do

 

install

 

and

 

operate

 

by

 

operator.

Use

 

safety

 

chain

 

when

 

fixes

 

the

 

fixture.

Be

 

sure

 

that

 

no

 

ventilation

 

slots

 

are

 

blocked,

 

otherwise

 

the

 

fixture

 

will

 

be

 

overheated.

Before

 

operating,

 

ensure

 

that

 

the

 

voltage

 

and

 

frequency

 

of

 

power

 

supply

 

match

 

the

 

power

 

requirements

 

of

 

the

 

fixture.

 

It’s

 

important

 

to

 

the

 

ground

 

with

 

yellow/green

 

conductor

 

to

 

earth

 

in

 

order

 

to

 

avoid

 

electric

shock.

 

Maximum

 

ambient

 

temperature

 

is

 

40

.

 

Don’t

 

operate

 

it

 

where

 

the

 

temperature

 

is

 

higher

 

than

this.

Don’t

 

connect

 

the

 

device

 

to

 

any

 

dimmer

 

pack.

First

 

run,

 

there

 

will

 

be

 

smoke

 

or

 

smells,

 

and

 

all

 

disappearing

 

a

 

few

 

minutes

 

later.

Make

 

sure

 

there

 

are

 

no

 

flammable

 

materials

 

close

 

to

 

the

 

fixture

 

while

 

operating,

 

as

 

it

 

is

 

fire

 

hazard.

 

Look

 

over

 

power

 

wires

 

carefully,

 

replace

 

immediately

 

if

 

there

 

is

 

any

 

damage.

Fixture

 

surface

 

temperature

 

may

 

reach

 

up

 

to

 

65

.

 

Don’t

 

touch

 

the

 

housing

 

bare

hand

 

during

its

 

operation.

 

Never

 

run

 

on

 

for

 

a

 

long

 

time

 

lest

 

shortening

 

lifespan.

 

Avoid

 

any

 

inflammable

 

liquids,

 

water

 

or

 

metal

 

objects

 

entering

 

the

 

fixture.

 

Once

 

it

 

happen,

 

cut

off

 

the

 

mains

 

power

 

immediately.

 

Do

 

not

 

operate

 

in

 

dirty

 

and

 

dusty

 

environment,

 

also

 

cleaning

 

fixtures

 

regularly.

Do

 

not

 

allow

 

children

 

to

 

operate

 

the

 

fixture.

Do

 

not

 

touch

 

any

 

wire

 

during

 

operation

 

as

 

there

 

might

 

be

 

a

 

hazard

 

of

 

electric

 

shock.

Please

 

read

 

the

 

instructions

 

carefully

 

which

 

includes

 

important

 

information

 

about

 

the

 

installation,

 

operation

 

and

 

maintenance.

 

Summary of Contents for V Inground VI-10QW

Page 1: ...the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN60598 2 17 1989 A2 1991 EN60598 1 2008 A11 2009 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements VI 10QW User Manual Please read the instructions carefully before us...

Page 2: ...e connection of power cable and signal line also measure the mains voltage on the main connector 8 Cleaning And Maintenance The cleaning must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates moist smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture Clean with lint free cloth us...

Page 3: ...g ensure that the voltage and frequency of power supply match the power requirements of the fixture It s important to the ground with yellow green conductor to earth in order to avoid electric shock Maximum ambient temperature is 40 Don t operate it where the temperature is higher than this Don t connect the device to any dimmer pack First run there will be smoke or smells and all disappearing a f...

Page 4: ...eam while the fixture is on To protect the machine power off 10s rear can electrify 2 Features V Inground is a high power and robust outdoor luminaries With cutting edge LED technology IP67 rated and drive over resistant construction the V Inground is specially designed for illuminating walkways landscape 316LStainless steel top cover die cast housing and plastic sleeve Optimal thermal management ...

Page 5: ...ction box sold separately there are two colors red and black for power cable red cable is positive black cable is grounding Three colors red white and black for signal line red line is white line is and black line is grounding 4 1 3 Connect wires to the mains power or signal cables through wire nuts or wiring terminal per code instruction For damp or wet locations use an IP rated junction box per ...

Page 6: ...5D 4 3 Connection Diagram 6D 5 Lumen Output Lumens 299 35lm Efficacy 20 65lm W Beam Angle 10 ...

Reviews: