Page 1: ......
Page 2: ...ction 5 4 Control Panel 8 5 How To Set The Unit 9 5 1 Main Function 9 5 2 Home Position Adjustment 15 6 Control By Universal DMX Controller 18 6 1 DMX512 Connection 18 6 2 Address Setting 19 6 3 DMX512 Configuration 20 7 Error Information 24 8 Troubleshooting 26 9 Fixture Cleaning 26 1E ...
Page 3: ...ation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked otherwise the unit will be overheated Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Minimum ambient temperature TA 0 Maximum ambient temperature TA 40 ...
Page 4: ...me after time The housing the lenses or the ultraviolet filter must be replaced if they are visibly damaged DO NOT open the unit as there are no user serviceable parts inside Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center if needed Disconnect the mains power if the ...
Page 5: ... 9 16 bit 16 Channels Control Mode DMX512 RDM Firmware Upgrade via DMX link Construction Display OLED display Data In Out 3 pin IP XLR 5 pin IP XLR is optional Power In Out Waterproof Power Connector in out Protection Rating IPX4 Features Variable CTO High brightness smooth color mixing powerful wash effect 3 x led zones can be controlled individually Equipped with a special patented plug structur...
Page 6: ... Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it...
Page 7: ...the hanging bracket Installation mode of a single angle adjustable equipment s hanging bracket Installation mode of the bolt Assembly method between two equipment Installation mode of the big hanging bracket operational 6E ...
Page 8: ...Assembly method between multiple equipment Warning no more than 7 equipment can be spliced vertically 7E ...
Page 9: ...menu DOWN To go forward to move down in the menu ENTER To perform the desired functions 3 DMX IN For DMX512 operation use 3 pin XLR cable to link the units together 5 pin XLR is optional 4 DMX OUT For DMX512 operation use 3 pin XLR cable to link the next unit 5 pin XLR is optional 5 POWER IN Used to connect to supply power 6 POWER OUT Used to connect to the next fixture 8E ...
Page 10: ...n until the required function is shown on the monitor Select the function by the ENTER button Use the UP DOWN button to choose the submenu press the ENTER button to store and automatically return to the last menu Press the MENU button or let the unit idle 30 seconds to exit menu mode The main functions are shown below 9E ...
Page 11: ...10E ...
Page 12: ...xit menu mode No DMX Status To select No DMX Status press the ENTER button to confirm Use the UP DOWN button to select Hold fixture continues to obey the last command it received Via DMX if DMX signal stops Blackout fixture blacks out if DMX signal stops or Manual the fixture will automatically read the DMX value in the Manual Test menu for operation after selecting this mode press the ENTER butto...
Page 13: ...low levels and high levels and coarser at medium levels Dimmer Speed To select Dimmer Speed press the ENTER button to confirm Use the UP DOWN button to select Fast Fast Speed or Smooth Slow Speed press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode White Balance To select White Balance press the ENTER button to confirm Use th...
Page 14: ...ess the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Auto Test Select Auto Test press the ENTER button to confirm the unit will run built in programs to automatically test Press the MENU button back to the last menu or exit menu mode after auto test Manual Test Select Manual Test press the ENTER button to confirm the present channel will show on the display u...
Page 15: ...he MENU button to exit Fixture Use Hour Select Fixture Use Hour press the ENTER button to confirm fixture use hour will show on the display press the MENU button to exit LED Use Time Select LED Use Time press the ENTER button to confirm LED use time will show on the display press the MENU button to exit Firmware Version Select Firmware Version press the ENTER button to confirm firmware version wil...
Page 16: ...ect the DMX PERSONALITY menu to set the channel mode of the fixture 4 8 8 9 16 channel Select the DMX PERSONALITY DESCRIPTION menu to display the current channel mode of the fixture Select the DEVICE HOURS menu to display the running time of the fixture 5 2 Home Position Adjustment Press the MENU button into menu mode then press the ENTER button for about 3 seconds into offset mode to adjust the h...
Page 17: ...elect Green1 press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 0 to 1000 press the ENTER button to store Press the MENU button to exit Green2 Enter offset mode Select Green2 press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 0 to 1000 press th...
Page 18: ... mode Select White2 press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 0 to 1000 press the ENTER button to store Press the MENU button to exit White3 Enter offset mode Select White3 press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 0 to 1000 p...
Page 19: ...DMX Controller 6 1 DMX512 Connection 1 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last unit 2 Connect the unit together in a daisy chain by XLR plug cable from the output of the unit to the input of the next unit The cable cannot be branched or split to a...
Page 20: ...2 so that the units can receive DMX signal Press the MENU button to enter menu mode select DMX Settings press the ENTER button to confirm use the UP DOWN button to select DMX Address press the ENTER button to confirm the present address will blinking the display use the UP DOWN button to adjust the address from 001 to 512 press the ENTER button to store Press the MENU button back to the last menu ...
Page 21: ...r about 3 seconds then the corresponding function will take into effect 4 Channels 8 bit Mode 1 CHANNEL DMX VALUE FUNCTION 1 000 255 RED 0 100 2 000 255 GREEN 0 100 3 000 255 BLUE 0 100 4 000 255 WHITE 0 100 8 Channels 16 bit Mode 2 CHANNEL DMX VALUE FUNCTION 1 000 255 RED 0 100 2 000 255 RED FINE 3 000 255 GREEN 0 100 4 000 255 GREEN FINE 5 000 255 BLUE 0 100 6 000 255 BLUE FINE 7 000 255 WHITE 0...
Page 22: ...0 100 6 000 255 STROBE DURATION 0 100 7 000 006 Blackout 007 255 Strobe Rate 8 000 005 No Effect 006 050 Ramp Up 051 100 Ramp Down 101 150 Ramp Up Down 151 200 Lightning 201 255 Random 9 Channels 16 bit Mode 4 CHANNEL DMX VALUE FUNCTION 1 000 255 RED 0 100 2 000 255 RED FINE 3 000 255 GREEN 0 100 4 000 255 GREEN FINE 5 000 255 BLUE 0 100 6 000 255 BLUE FINE 21E ...
Page 23: ...090 091 094 095 099 100 103 104 108 109 112 113 117 118 121 122 126 127 130 131 135 136 139 140 144 145 148 149 153 154 157 158 162 163 166 167 171 LINEAR CTO 8000K 2500K Null 8000K 7900K 7800K 7700K 7600K 7500K 7400K 7300K 7200K 7100K 7000K 6900K 6800K 6700K 6600K 6500K 6400K 6300K 6200K 6100K 6000K 5900K 5800K 5700K 5600K 5500K 5400K 5300K 5200K 5100K 5000K 4900K 4800K 4700K 4600K 4500K 4400K 43...
Page 24: ... 4100K 4000K 3900K 3800K 3700K 3600K 3500K 3400K 3300K 3200K 3100K 3000K 2900K 2800K 2700K 2600K 2500K 16 Channels Mode 5 CHANNEL DMX VALUE FUNCTION 1 000 255 RED1 0 100 2 000 255 GREEN1 0 100 3 000 255 BLUE1 0 100 4 000 255 WHITE1 0 100 5 000 255 RED2 0 100 6 000 255 GREEN2 0 100 7 000 255 BLUE2 0 100 8 000 255 WHITE2 0 100 9 000 255 RED3 0 100 23E ...
Page 25: ...01 255 Random 7 Error Information 1 CPU B Error Check whether the 485 DATA leads on the PCB board are installed in place or disconnected Check whether the 485 DATA lead is disconnected Check whether the relevant signal circuit 485 DATA on the PCB board is damaged 2 Fan3 can t start Check if the fan is not running Check if the fan leads are installed in place or disconnected Check if the fan is dam...
Page 26: ...ent is damaged 4 Fan3 speed too slow Check if the fan is out of order Check if there are other interference items in the fan operating range 5 Fan3 speed too fast Check if the fan is out of order Check if the fan circuit on the motherboard breaks down The position of each fan of the fixture 25E ...
Page 27: ...use another DMX controller 5 Check to see if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 9 Fixture Cleaning The cleaning of internal a...
Page 28: ...Innovation Quality Performance ...