6.2 Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to
512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select DMX Address, press the ENTER button to
confirm, the present address will blink on the display, use the UP/DOWN button to adjust the
address from 1 to 512, press the ENTER button to store. Press the MENU button back to the last
menu or let the unit idle 30 seconds to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
Channel mode
Unit 1
Address
Unit 2
Address
Unit 3
Address
Unit 4
Address
12 channels
1
13
25
37
6.3 DMX512 Configuration
Please refer to below configurations to control the fixtures
Attentions:
1.
The unit will maintain the last condition until reset if you cut-off the DMX signal.
2.
For the channel Function, keep the value for about 3 seconds, then the corresponding function
will take into effect.
12 Channels Mode:
CHANNEL
VALUE
FUNCTION
1
000-255
PAN
0°
540°
2
000-255
PAN FINE
3
000-255
TILT
0°
270°
4
000-255
TILT FINE
5
000-255
PAN/TILT SPEED
fast to slow
6
000-255
DIMMER
0%
100%
7
000-007
008-015
016-131
STROBE
Standby
Open
Strobe, Slow to Fast
16C