Page 2: ...p 6 4 1 Color Gobo 6 4 2 Light Source 7 4 3 Change The Lamp 7 5 How To Set The Unit 9 5 1 Main Function 9 5 2 Home Position Adjustment 13 6 Control By Universal DMX Controller 15 6 1 DMX512 Connection 15 6 2 Address Setting 16 6 3 DMX512 Configuration 16 7 Troubleshooting 19 8 Fixture Cleaning 19 1C ...

Page 3: ...se the unit will be overheated Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Minimum ambient temperature TA 0 Maximum ambient temperature TA 40 DO NOT connect the device to any dimmer pack During initial start up some smoke or smell may ari...

Page 4: ...sistance center if needed Disconnect the mains power if the fixture is has not been used for a long time DO use the original packing materials before transporting it again Hot lamp explosion hazard DO NOT open the unit within 15 minutes after switching off DO replace the bulb once it is damaged deformed or life expired DO NOT look directly at the light while the bulb is on Never touch bulb with ba...

Page 5: ...colors plus open Gobo Wheel 1 fixed gobo wheel with 15 gobos plus open Control DMX Channel 12 channels Control Mode DMX Pri Sec Sound Active Firmware Upgrade Update via DMX link Construction Display LCD display Data In Out 3 pin XLR 5 pin XLR is optional Power In Out Power Connector in out Protection Rating IP20 Features Prism 8 facet prism rotating in both directions 0 100 smooth dimming Various ...

Page 6: ...Dimension Weight 284x255x387mm 9 2kgs 11 2 x10 x15 2 in 20 3lbs Photometrics Diagram 3 Control Panel 5C ...

Page 7: ... DISPLAY Used to show the various menus and the selected function 5 FUSE T 5A Protects the unit from over voltage or short circuit 6 POWER IN OUT Used to connect to supply power Used to connect to the next fixture 7 DMX IN OUT Use 3 pin XLR cable to link the units and input output DMX signal 5 pin XLR is optional 4 Color Gobo and Lamp 4 1 Color Gobo DANGER Install the color wheel gobo wheel with t...

Page 8: ...shielding When lighting up the lamp operates at high pressure and there is a slight risk of arc tube rupture The risk increases with age temperature and improper handling of the lamp Do not use the lamp longer than its lifespan Make sure the lamp is located in the center of the reflector for the best projection 4 3 Change The Lamp Do not use this lamp more than 6000 hours using the lamp any longer...

Page 9: ...the lamp and connect a new lamp that must be the same type with the old one And then place the new lamp into the lamp recess Finally reinstall the head cover fastening it securely before reapplying power Warning The installing direction of lamp 8C ...

Page 10: ...until the required function is shown on the monitor Select the function by the ENTER button Use the UP DOWN button to choose the submenu press the ENTER button to store and automatically return to the last menu Press the MENU button or let the unit idle 30 seconds to exit menu mode The main functions are shown below 9C ...

Page 11: ...10C ...

Page 12: ...ss the ENTER button to setup Press and hold the MENU button about one second or wait for 30 seconds to exit the menu mode DMX State To select DMX State press the ENTER button to confirm Use the DOWN UP button to select Pri Sec Hold or Blackout Once selected press the ENTER button to setup Press and hold the MENU button about one second or wait for 30 seconds to exit the menu mode Sound State To se...

Page 13: ...ect On LED display always on or Off LED display off when not use Once selected press the ENTER button to setup Press and hold the MENU button about one second or wait for 30 seconds to exit the menu mode Auto Test To select Auto Test press the ENTER button and the unit will run self test by built in program Press and hold the MENU button about one second or wait for 30 seconds to exit the menu mod...

Page 14: ...the display will show the version of software of the unit Press and hold the MENU button about one second or wait for 30 seconds to exit the menu mode Defaults To select Defaults press the ENTER button to confirm Use the DOWN UP button to select No or Yes Once selected press the ENTER button to setup Press and hold the MENU button about one second or wait for 30 seconds to exit the menu mode Reset...

Page 15: ... to adjust the value from 0 to 255 press the ENTER button to store Press the MENU button to exit COLOR OFFSET To select the Color Offset press the ENTER button to confirm Use the DOWN UP button to adjust the value from 127 to 127 press the ENTER button to store Press the MENU button to exit GOBO OFFSET To select the Gobo 1 Offset press the ENTER button to confirm Use the DOWN UP button to adjust t...

Page 16: ...signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Each lighting unit needs to have a DMX address to receive the data by the controller The address number is between 1 512 5 The end of the DMX...

Page 17: ...owing diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 12 channels 1 13 25 37 6 3 DMX512 Configuration Please refer to below configurations to control the fixtures Attentions 1 The unit will maintain the last condition until reset if you cut off the DMX signal 2 For the channel Function keep the value for about 3 ...

Page 18: ... Open Color1 Color2 Color3 Color4 Color5 Color6 Color7 Color8 Color9 Color10 Color11 Color12 Color13 Color14 Rotation Fast to Slow Stop Rotation Slow to Fast 9 000 003 004 007 008 011 012 015 016 019 020 023 024 027 028 031 032 035 036 039 040 043 044 047 048 051 052 055 056 059 060 063 064 068 069 072 073 076 077 080 GOBO Open Gobo1 Gobo2 Gobo3 Gobo4 Gobo5 Gobo6 Gobo7 Gobo8 Gobo9 Gobo10 Gobo11 Go...

Page 19: ...07 008 255 PRISM No Effect Prism Effect 11 000 127 128 189 190 193 194 255 R PRISM Index 0 360 Rotation Fast to Slow Stop Rotation Slow to Fast 12 000 079 080 084 085 089 090 094 095 099 100 109 110 119 120 129 130 139 140 199 200 209 210 229 230 239 240 249 250 255 FUNCTION Null Pan Tilt Motors reset Color motor reset Gobo motor reset Shutter Dimmer Prism reset Enable blackout while pan tilt move...

Page 20: ...h voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition D The lamp is cutting out intermittently 1 The lamp is not working well Check the mains voltage either too high or too low 2 Internal tem...

Page 21: ...20C ...

Page 22: ...21C ...

Page 23: ...ce with the provision of the Electromagnetic Compatibility EMC Directive 2014 30 EU EN 55103 1 2009 A1 2012 EN 55103 2 2009 EN 61000 3 2 2014 EN 61000 3 3 2013 Harmonized Standard EN 60598 2 17 1989 A2 1991 EN 60598 1 2008 A11 2009 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements 22C ...

Page 24: ...Innovation Quality Performance ...