ACME PVD EC Installation & Maintenance Instructions Manual Download Page 4

ADDITIONAL INSTALLATION AND MAINTENANCE INSTRUCTIONS 

for the PVH Model with hurricane construction that complies with  

Florida Building Code including High Velocity Hurricane Zones (HVHZ)

This product has been issued a Notice of Acceptance 

(NOA) by Miami-Dade County, Florida. The full document 

can be found on Miami-Dade County, Florida website 

 

www.miamidade.gov/building/pc-search_app.asp.  This product is 

marked on its label by a statement “Miami-Dade County Product 

Control Approved”. 
This product shall be available for inspection at the job site at the 

request of the Building Official.

This product may be installed on a wooden, metal or concrete deck 

following the requirements shown in Figure 1. The matching curb of 

Model CH for this particular use must be used.
It is the installers responsibility to follow the installation instructions 

including a check that all fasteners in the outer shell of the product 

have been checked and tightened.
If the fan has to be replaced, the curb for attachment of the fan to the 

deck must also be replaced. The matching curb of Model CH for this 

particular use must be used.

NOTE:

 Hurricane curbs have a tighter fit than standard curbs.

Note: Curb mounting hardware provided by others.

Figure 1

 - Installation of the product complying with Florida Building Code including High Velocity Hurricane Zones (HVHZ) on a 

wooden, metal or concrete deck.

4

Summary of Contents for PVD EC

Page 1: ...d methods that will not cause damage Fans should be lifted using slings and padding or spreaders to avoid damage CAUTION Always make sure that all lifting and handling equipment and techniques conform...

Page 2: ...oisture or dirt accumulations are found on parts the source should be located and eliminated Fans should be rotated at each inspection by hand ten to fifteen revolutions to redistribute the motor and...

Page 3: ...into the wheel MAINTENANCE 1 Under normal usage no spare parts are recommended for one year of operation Recommended spare parts are shown on page 4 2 CAUTION Before proceeding make sure electrical s...

Page 4: ...is product may be installed on a wooden metal or concrete deck following the requirements shown in Figure 1 The matching curb of Model CH for this particular use must be used It is the installers resp...

Page 5: ...d electromagnetic fields in the vicinity of current carrying conductors and permanent magnet motors can result in a serious health hazard to persons with cardiac pacemakers metal implants and hearing...

Page 6: ...otations Rotation can be changed by swapping any of the Red Black and Blue wires connecting the control board to the motor at terminals T1 T2 and T3 Installation 1 Wire motor in accordance with local...

Page 7: ...e switch and mounting plate fit in a standard gang box and wired to Dual Potentiometer Speed Dial The speed dial can be mounted up to 100 ft from fan using additional wire by others Building Control 0...

Page 8: ...tain that they are secure Fault Indication A red LED on the control board provides fault indication During a fault this LED will blink a specific number of times to identify the fault that has occurre...

Page 9: ...ontrol cable and quick connect Molex plug that can be plugged into the Molex plug on dual speed dial The supplied unmounted toggle switch will select the Low LO or High HI speed on the speed controlle...

Page 10: ...10 FIGURE 7 PerfectSpeed Control Cable FIGURE 7A Remote Potentiometer A Variable 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Speed B Potentiometers and or speed select switch mounted up to 100 ft from...

Page 11: ...ack Red White Wired in Field Red to Red White to White Black to Black A Variable 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Speed B B Potentiometers and or speed select switch mounted up to 100 ft from...

Page 12: ...to discharge any residual voltage 2 Check the rotation and speed of the motor Determine if the motor can spin freely by hand without effort or assisted means If any binding occurs replace the motor an...

Page 13: ...Bracket 6 2 Hood Fastener 3 8 Disconnect Switch 1 3 Windband 1 9 Support Side Birdscreen 2 4 Motor 1 10 Wheel 1 5 Separator Plate 2 11 Conduit 1 6 Motor Base 1 12 Curb Base and Orifice 1 PVD Exploded...

Page 14: ...y claim the Company shall have the option either to inspect the product while in Purchaser s possession or to request Purchaser to return the product to the Company at Purchaser s expense for inspecti...