07/ Error Information
CPU-B/C/D Error
LED Temperature Error
LED Timeout Use
LED Too Hot Off
Color Cal IC Error
Check if the color calibration IC is damaged.
Check whether the color calibration IC board is inserted well and
whether the electronic components are well soldered.
Check if the motherboard is malfunctioning.
Check whether the R76 bit resistors and other components on the
motherboard are well soldered.
When the fixture temperature reaches 82
℃
, it will automatically turn
off to protect the fixture.
Check whether the temperature detecting board is normal.
Check whether the components of the temperature detecting board
are damaged.
Check whether the lead on the temperature detecting board is
installed in place or disconnected.
Error codes are shown continuously in the display when the fixture fails and they will not
disappear until the fixture is repaired.
Check whether the 485 (DATA) leads on the PCB board are installed in
place or disconnected.
Check whether the related 485 (DATA) signal circuit on the PCB board
is damaged.