background image

 
 

button  to select the 

Blackout 

(blackout) or 

Hold 

(keep the present status). Once selected, press 

the 

ENTER

 button to save or automatically exit menu mode without any change. Back to the 

previous functions without any change press the 

MENU

 button. 

Back Light 

Select the 

Back Light

, press the 

ENTER

 button and the display will blink. Use the 

DOWN

 and 

UP

 

button  to select the 

On 

or 

Off

. Once selected, press the 

ENTER

 button to save or automatically exit 

menu mode without any change. Back to the previous functions without  any change press the 

MENU

 button. 

White Balance 

Select the 

White Balance

, press the 

ENTER

 button and the display will blink. Use the 

DOWN

 and 

UP

 button to find the color (

Red

Green

,

 Blue

) you wish to adjust. Press the 

ENTER

 button to 

confirm and use 

DOWN

 and 

UP

 button  to adjust the value (

125~255

), once select press 

ENTER

 

button to setup or automatically exit menu  mode without  any change after 7seconds. To go back 

to the last function without  any change press the 

MENU

 button. 

Manual Test 

Select the 

Manual Test

, press the 

ENTER

 button  and the display will blink. Use the 

DOWN

 and 

UP

 

button to find the 

Red

Green

Blue

White

Zoom

 and 

Dimmer

 or 

Strobe

. Once you find a 

function or color you wish to test, press the 

ENTER

 button,  the displayed value will begin to flash. 

You can now adjust the values (

000~255

) by pressing the 

DOWN

 and 

UP

 button.  Once you have 

finished testing press the 

ENTER

 button. To go back to the last function without any change press 

the 

MENU

 button. 

Auto Test 

Select the 

Auto Test

,

 

press the

 ENTER 

button, the unit will run the built-in programmer for self test. 

Press the 

MENU 

button  to exit. 

Temp. 

Select the 

Temp.

 , press the 

ENTER

 button and the display will show the current running 

 

8A 

Summary of Contents for MP-350Z

Page 1: ...MP 350Z User Manual Please read the instructions carefully beforeuse...

Page 2: ...tions 3 3 How To Set The Unit 4 3 1 Control panel 4 3 2 Main Functions 5 3 3 Home Position Adjustment 9 4 How to Control the Unit 9 4 1 DMX Controller 10 4 2 DMX 512 Configurations 10 5 DMX 512 Connec...

Page 3: ...erials close to the unit while operating as it is fire hazard Please use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base Maximum ambient...

Page 4: ...fixed to avoid vibration and slipping while operating Make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the fixtures weight Also...

Page 5: ...it 3 1 Control panel 1 DMX IN For DMX512 link use 3 pin XLR plug cable to input DMX512 single 2 DMX OUT For DMX512 link use 3 pin XLR plug cable to output DMX512 single to the next unit 3 DMX IN For D...

Page 6: ...e 13 POWERCON OUT Connect to supply power to the next fixture 14 Fuse T 6 3A Protect the fixture from damage of current 3 2 Main Functions To select any of the given functions press the MENU button up...

Page 7: ...ton to change the DMX 512 Address and then press the ENTER button to save Back to the previous functions without any change press the MENU button Channel Mode Select the Channel Mode press the ENTER b...

Page 8: ...ncrease in light intensity appears to be linear as DMX value is increased Mode 2 Square Law Light intensity control is finer at low levels and coarser at high levels Mode 3 Inverse Square Law Light in...

Page 9: ...use DOWN and UP button to adjust the value 125 255 once select press ENTER button to setup or automatically exit menu mode without any change after 7seconds To go back to the last function without any...

Page 10: ...position adjustment Enter offset mode Select Zoom Offset press the ENTER button to confirm the present position will blink on the display use the UP DOWN button to offset the value from 0 to 255 press...

Page 11: ...tton to change the DMX512 address Once the address has been selected press and keep ENTER button to save To go back to the functions without any change press the MENU button again If you use please re...

Page 12: ...11A...

Page 13: ...hain by XLR plug from the output of the unit to the input of the next unit The cable can not branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered jo...

Page 14: ...e power on LED B Not responding toDMXcontroller 1 DMX LED should be on If not check DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the addres...

Page 15: ...ncy depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal...

Page 16: ...e provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 A1 2012 EN55103 2 2009 EN61000 3 2 2014 EN61000 3 3 2013 HarmonizedStandard EN 60598 1 2015 EN 60598 2 17 1989...