background image

STAGE TRI-PAR 12FC 

MP-12FC 

User Manual 

Please read the instructions carefully before use 

Summary of Contents for MP-12FC

Page 1: ...STAGE TRI PAR 12FC MP 12FC User Manual Please read the instructions carefully before use ...

Page 2: ...LE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 How To Set The Fixture 4 How To Control The Fixture 5 DMX 512 Configuration 6 DMX 512 Connections 7 Troubleshooting 8 Fixture Cleaning 1 A ...

Page 3: ...g ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperature TA 40 Don t operate it where the temperature is higher than this Don t connect the device to any dimmer pack First run there will be smoke or smells and all disappearing a few minut...

Page 4: ...istance center Disconnect the mains power if the fixture is not used for a long time Do use original packing materials once transport it again Do not look directly at the LED light beam while the fixture is on Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the ...

Page 5: ...eight 6kg 3 How To Set The Fixture 3 1 Control Panel 1E A Display To show the various menus and the selected functions A 2E A LED DMX On DMX input present MASTER On Master Mode SLAVE On Slave Mode SOUND Flashing Sound activation 4 A ...

Page 6: ... signal A 6E A Mains output Connect to supply power for the unit 3 2 Main Function To select any functions press MENU button until the required one is shown on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will automatically return to the main functions ...

Page 7: ... Mode No Blackout Blackout Mode Yes Blackout Software Version Inversion LED off Sound Mode on Sound Mode off LED on Self Test Show mode Normal Channels Mode Master Slave mode Fixture Temperature White balance Manual mode Dimmer mode 1 Dimmer mode 4 6 A ...

Page 8: ...to the functions without any change press the MENU button Slave Mode Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the normal or slave 2 mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after7seconds To go back to th...

Page 9: ...MENU button again Optically Linear The increase in light intensity appears to be linear as DMX value is increased Square Law Light intensity control is finer at low levels and coarser at high levels Inverse Square Law Light intensity control is coarser at low levels and finger at high levels S cure Light intensity control is finger at low levels and high levels and coarser at medium levels Sound m...

Page 10: ...hange after 7seconds Back to the functions without any change press MENU button again Display Inverse Press MENU button until is blinking on the display Use DOWN and UP button to select display normal or display inverse press ENTER button to setup Back to the functions without any change press MENU button White Balance Press the MENU button up to when the is shown on the display Pressing ENTER but...

Page 11: ...he functions press the MENU button Temperature Test Press the MENU button up to when the is blinking on the display Pressing ENTER button and the display will show the temperature of the unit To go back to the functions press the MENU button again Fixture Hours Press the MENU button up to when the is blinking on the display Pressing ENTER button and the display will show the number of working hour...

Page 12: ... to give an automatic sound activated synchronized light show This function is good when you want an instant show Any fixture can act as a Master or as a Slave 2 light show In slave mode Slave 1 means the unit works normally and Slave 2 means 2 light show In order to create a great light show you can set Slave 2 on the second unit to get contrast movement to each other even if you have two units o...

Page 13: ...s 8 channels 5 DMX512 Configuration 4 channels mode CHANNEL VALUE FUNCTION 1 0 255 RED 0 100 2 0 255 GREEN 0 100 3 0 255 BLUE 0 100 4 0 255 WHITE 0 100 5 channels mode CHANNEL VALUE FUNCTION 1 0 255 RED 0 100 2 0 255 GREEN 0 100 3 0 255 BLUE 0 100 4 0 255 WHITE 0 100 5 0 255 DIMMER 0 100 12 A ...

Page 14: ... Color 1 016 023 Color 2 024 030 Color 3 031 038 Color 4 039 046 Color 5 047 054 Color 6 055 061 Color 7 062 069 Color 8 072 077 Color 9 078 085 Color 10 086 092 Color 11 093 100 Color 12 101 108 Color 13 109 116 Color 14 117 123 Color 15 124 131 Color 16 132 139 Color 17 140 147 Color 18 148 154 Color 19 155 162 Color 20 163 170 Color 21 13 A ...

Page 15: ... Color 28 225 232 Color 29 233 240 Color 30 241 247 Color 31 248 255 Color 32 6 0 255 DIMMER 0 100 7 0 255 DIMMER Fine 0 100 8 STROBE 000 007 Off 008 015 Open 016 131 Strobe 132 139 Open 140 181 Slow open fast close 182 190 Open 191 231 Slow close fast open 232 239 Open 240 247 Random strobe 248 255 Open 14 A ...

Page 16: ...gh to maintain the DMX circuit when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture 4 Each lighting fixture needs to have an address set to receive the data sent by the controller...

Page 17: ...e to high voltage cables that may cause damage or interference to DMX interface circuit C No response to the sound 1 Make sure the fixture does not receive DMX signal 2 Check microphone to see if it is good by tapping the microphone D One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be o...

Page 18: ......

Page 19: ......

Page 20: ...Innovation Quality Performance ...

Reviews: