background image

 
 

 

15B

3.

 

Universal

 

DMX

 

controller

 

No

 

need

 

to

 

turn

 

the

 

unit

 

off

 

when

 

you

 

change

 

the

 

DMX

 

address,

 

as

 

new

 

DMX

 

address

 

setting

 

will

 

be

 

affect

 

at

 

once.

 

Every

 

time

 

you

 

turn

 

the

 

unit

 

on,

 

it

 

will

 

show

 

 

on

 

the

 

display

 

and

 

move

 

all

 

the

 

motors

 

to

 

their

 

‘home’

 

position

 

and

 

you

 

may

 

hear

 

some

 

noises

 

for

 

about

 

20

 

seconds.

 

After

 

that

 

the

 

unit

 

will

 

be

 

ready

 

to

 

receive

 

DMX

 

signal

 

or

 

run

 

the

 

built

 

in

 

programs.

 

 

4.1

 

Master/Slave

 

Built

 

In

 

Preprogrammed

 

Function

   

By

 

linking

 

the

 

units

 

in

 

master/slave

 

connection,

 

the

 

first

 

unit

 

will

 

control

 

the

 

other

 

units

 

to

 

give

 

an

 

automatic,

 

sound

 

activated,

 

synchronized

 

light

 

show.

 

This

 

function

 

is

 

good

 

when

 

you

 

want

 

an

 

instant

 

show.

 

You

 

have

 

to

 

set

 

the

 

first

 

unit

 

in

 

master

 

mode

 

 

and

 

select

 

 

(show

 

1),

 

 

(Show

 

2),

 

 

(Show

 

3)

 

or

 

 

(show

 

4)

 

mode.

 

Its

 

DMX

 

input

 

jack

 

will

 

have

 

nothing

 

plugged

 

into

 

it,

 

and

 

its

 

master

 

LED

 

will

 

be

 

constantly

 

on

 

and

 

sound

 

LED

 

will

 

flash

 

to

 

the

 

music.

 

The

 

other

 

units

 

will

 

have

 

to

 

set

 

in

 

slave

 

mode

 

and

 

select

 

 

(normal)

 

or

 

 

(2

 

light

 

show)

 

mode.

 

Their

 

DMX

 

cables

 

plugged

 

into

 

the

 

DMX

 

input

 

jacks

 

(daisy

 

chain)

 

and

 

the

 

slave

 

LED

 

lights

 

will

 

be

 

constantly

 

on.

 

2

light

 

show

 

In

 

slave

 

mode,

 

 

means

 

the

 

unit

 

works

 

normally

 

and

 

 

means

 

2

light

 

show.

 

In

 

order

 

to

 

create

 

a

 

great

 

light

 

show,

 

you

 

can

 

set

 

 

on

 

the

 

second

 

unit

 

to

 

get

 

contrast

 

movement

 

to

 

each

 

other,

 

even

 

if

 

you

 

have

 

two

 

units

 

only.

 

 

4.2

 

Easy

 

Controller

   

The

 

easy

 

remote

 

control

 

is

 

used

 

only

 

in

 

master/slave

 

mode.

 

By

 

connecting

 

to

 

the

 

1/4”

 

microphone

 

jack

 

of

 

the

 

first

 

unit,

 

you

 

will

 

find

 

that

 

the

 

remote

 

controller

 

on

 

the

 

first

 

unit

 

will

 

control

 

all

 

the

 

other

 

units

 

for

 

Stand

 

by,

 

Function

 

and

 

Mode

 

selection.

 

 

 

Summary of Contents for LED-MS350B

Page 1: ...LED MS350B User Manual Please read the instruction carefully before use ...

Page 2: ...3 1 Fixture Overview 5 3 2 Main Function 6 3 3 Home Position Adjustment 13 4 How to Control the Unit 14 4 1 Master Slave Built In Preprogrammed Function 15 4 2 Easy Controller 15 4 3 DMX Controller 16 5 DMX512 Configuration 17 6 DMX Connection 19 7 Troubleshooting 20 8 Fixture Cleaning 21 ...

Page 3: ...re hazard y Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base y Maximum ambient temperature is Ta 40 DO NOT operate it where the temperature is higher than this y Unit surface temperature may reach up to 85 DO NOT touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down ...

Page 4: ...cure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 2 Technical Specifications Constructions Stylish design with fire retardan...

Page 5: ...X channel modes 8 11CH LED display for easy navigation and addressing 0 100 smooth dimming and variable strobe speeds Data In Out 3 PIN XLR sockets RDA Remote DMX addressing DMX address can be remotely set up by universal controller Specification y Power Voltage AC 100 240V 50 60Hz y Power Consumption 134W y Light Source 1 x 60W White LED y Beam Angle 15 y Dimension 292 x 169 x 425mm y Weight 7 2K...

Page 6: ... the various menus and the selected functions 3 Button MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions 4 Power IN OUT Used to connect the fixture to mains power 5 DMX IN For DMX512 link use 3 pin XLR plug cable to link the DMX controller and the fixture and ...

Page 7: ...ct 3 2 Main Function To select any functions press the MENU button until the required function is showing on the display Select the function by pressing the ENTER button and the display will blink Use the DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup to go back to the functions without any changes press the MENU button again Hold and...

Page 8: ...7B ...

Page 9: ...n Hold and press the MENU button for one second or wait for one minute to exit the menu mode SHOW MODE To select the press the ENTER button to show the SHOW MODE on the display Use the DOWN UP button to select the Show 1 Show 2 Show 3 or Show 4 mode Once the show mode has been selected press the ENTER button to setup to go back to the functions without any changes press the MENU button again Hold ...

Page 10: ...U button again Hold and press the MENU button for one second or wait for one minute to exit the menu mode SOUND MODE To select the press the ENTER button to show the SOUND MODE on the display Use the DOWN UP button to select the sound mode on or sound mode off Once the mode has been selected press the ENTER button to setup to go back to the functions without any changes press the MENU button again...

Page 11: ...ress the MENU button for one second or wait for one minute to exit the menu mode LED DISPLAY To select the press the ENTER button to show the LED DISPLAY on the display Use the DOWN UP button to select the LED display on or LED display off mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any changes press the MENU button again Hold and press ...

Page 12: ...n Hold and press the MENU button for one second or wait for one minute to exit the menu mode DIMMER CALIBRATE To select the press the ENTER button to show the DIMMER CALIBRATE on the display Use the DOWN UP button to calibrate the dimmer for a maximum output from 50 limited to 50 of the really max output to 100 maximum output is not limited Once calibrated press the ENTER button to setup to go bac...

Page 13: ...wait for one minute to exit the menu mode SOFTWARE VERSION To select the press the ENTER button to show the SOFTWARE VERSION on the display and the display will show the version of software of the unit To go back to the functions without any changes press the MENU button again Hold and press the MENU button for one second or wait for one minute to exit the menu mode DEFAULTS SETTING To select the ...

Page 14: ...e corresponding functions will set to defaults setting To go back to the functions without any changes press the MENU button again Hold and press the MENU button for one second or wait for one minute to exit the menu mode RESET To select the press the ENTER button to show the RESET on the display Press the ENTER button and all channels of the unit will return to their standard position 3 3 Home Po...

Page 15: ...R OFFSET on the display Use the DOWN and UP button to adjust the value from 127 to 127 press the ENTER button to store Press the MENU button to exit Gobo home position adjustment To select the press the ENTER button to show the GOBO OFFSET on the display Use the DOWN and UP button to adjust the value from 127 to 127 press the ENTER button to store Press the MENU button to exit Gobo rotation home p...

Page 16: ...aster mode and select show 1 Show 2 Show 3 or show 4 mode Its DMX input jack will have nothing plugged into it and its master LED will be constantly on and sound LED will flash to the music The other units will have to set in slave mode and select normal or 2 light show mode Their DMX cables plugged into the DMX input jacks daisy chain and the slave LED lights will be constantly on 2 light show In...

Page 17: ...the units can receive DMX signal Press the MENU button up to when the is showing on the display Press the ENTER button and the display will blink Use the DOWN and UP button to change the DMX512 address Once the address has been selected press and keep the ENTER button pressed up to when the display stops blinking or storing automatically 7 seconds later To go back to the functions without any chan...

Page 18: ...17B 5 DMX512 Configuration 8 Channels Mode ...

Page 19: ...18B 11 Channels Mode ...

Page 20: ...t The cable can not branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when power is disconnected to the unit 4 Each lighting unit needs to have an address set to receive the dat...

Page 21: ...k DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage ...

Page 22: ... Cleaning The cleaning must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates moist smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture y Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 30 days ...

Page 23: ...h the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...