background image

 
 

 

6B 

3.2 Main Function   

To select any functions, press the 

MENU

 button until the required function is showing on the 

display. Select the function by pressing the 

ENTER

 button and the display will blink. Use the 

DOWN

 and 

UP

 button to change the mode. Once the required mode has been selected, press the 

ENTER

 button to setup to go back to the functions without any changes press the 

MENU 

button 

again. Hold and press the 

MENU

 button for one second or wait for one minute to exit the menu 

mode. 

The main functions are shown below: 

Summary of Contents for LED BEAM 350

Page 1: ...LED MB350 User Manual Please read the instruction carefully before use ...

Page 2: ... 4 3 1 Rear Panel 4 3 2 Main Function 6 3 3 Home Position Adjustment 12 4 How to Control the Unit 13 4 1 Master Slave Built In Preprogrammed Function 14 4 2 Easy Controller 14 4 3 DMX Controller 15 5 DMX512 Configuration 16 6 DMX Connection 18 7 Troubleshooting 19 8 Fixture Cleaning 20 ...

Page 3: ...e hazard Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base Maximum ambient temperature is Ta 40 DO NOT operate it where the temperature is higher than this Unit surface temperature may reach up to 85 DO NOT touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down before ...

Page 4: ... are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 2 Technical Specifications DMX channel modes ...

Page 5: ...pecification Power Voltage AC 100 240V 50 60Hz Power Consumption 130W Light Source 1 x 60W White LED Beam Angle 6 Fuse T 3 15A Dimension 292 x 185 x 461mm Weight 7 5Kgs 3 How To Set The Unit 3 1 Rear Panel ...

Page 6: ...ected functions ENTER To confirm the selected functions 4 POWER IN OUT Connect the fixture to mains power 5 DMX IN For DMX512 link use 3 pin XLR plug cable to link the DMX controller and the fixture and input the DMX signal 6 DMX OUT For DMX512 link use 3 pin XLR plug cable to link the next fixture and output the DMX signal 7 Fuse T 3 15A Protect the fixture from damage of over current 8 Only For ...

Page 7: ...NTER button and the display will blink Use the DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup to go back to the functions without any changes press the MENU button again Hold and press the MENU button for one second or wait for one minute to exit the menu mode The main functions are shown below ...

Page 8: ...7B ...

Page 9: ...w Mode To select the Show Mode press the ENTER button to show the SHOW MODE on the display Use the DOWN and UP button to select the Show 1 Show 2 or Show 3 Show 4 Mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode ...

Page 10: ...as been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Sound Sense To select the Sound Sense press the ENTER button to show the SOUND SENSE on the display Use the DOWN and UP button to adjust the sound sensitivity from 0 to 100 press the ...

Page 11: ...nute to exit the menu mode Function Delay To select the Function Delay press the ENTER button to show the FUNCTION DELAY on the display Use the DOWN and UP button to select the No Delay or 1S Delay 2S Delay 3S Delay wait for 1 2 3 seconds before these functions of 8 11CH are activated deactivated Once selected press the ENTER button to setup to go back to the functions without any change press the...

Page 12: ...press the MENU button about one second or wait for one minute to exit the menu mode Firmware Version To select the Firmware Version press the ENTER button to show the FIRMWARE VERSION on the display and the display will show the version of software of the unit To go back to the functions press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the ...

Page 13: ...ss the ENTER button and the corresponding functions will set to defaults setting to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Reset To select the Reset press the ENTER button to show the RESET on the display and all channels of the unit will return to their standard position T...

Page 14: ...button to store Press the MENU button to exit GOBO 1 OFFSET Gobo1 home position adjustment To select the Gobo 1 Offset press the ENTER button to show the GOBO 1 OFFSET on the display Use the DOWN and UP button to adjust the value from 127 to 127 press the ENTER button to store Press the MENU button to exit R GOBO 1 OFFSET Gobo1 rotation home position adjustment To select the R Gobo 1 Offset press ...

Page 15: ...nits will have to set in slave mode and select Slave 1 normal or Slave 2 2 light show mode Their DMX cables plugged into the DMX input jacks daisy chain and the slave led lights will constantly on 2 light show In slave mode Slave 1 means the unit works normally and Slave 2 means 2 light show In order to create a great light show you can set Slave 2 on the second unit to get contrast movement to ea...

Page 16: ... Use the DOWN and UP button to change the DMX512 address Once the address has been selected press and keep the ENTER button pressed up to when the display stops blinking or storing automatically 7 seconds later To go back to the functions without any change press the MENU button again Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Add...

Page 17: ...16B 5 DMX512 Configuration 8 Channels Mode ...

Page 18: ...17B 11 Channels Mode ...

Page 19: ... or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when power is disconnected to the unit 4 Each lighting unit needs to have an address set to receive the data sent by the controller The...

Page 20: ...ee if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX inter...

Page 21: ...ure Cleaning The cleaning must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates moist smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 30 days ...

Page 22: ...21B ...

Page 23: ...ith the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008 All 2009 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...

Page 24: ...23B Innovation Quality Performance Широкий ассортимент оборудования ACME на www maxlight ru ...

Reviews: