background image

 

2A 

  1. Safety Introductions   

 

 

 

WARNING 

 

 

Please keep this User Manual for future consultation. If you sell the fixture to another 

user, be sure that they also receive this instruction booklet. 

 

Unpack and check carefully there is no transportation damage before using the fixture. 

 

Before  operating,  ensure  that  the  voltage  and  frequency  of  power  supply  match  the 

power requirements of the fixture. 

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric 

shock. 

 

Disconnect main power before servicing and maintenance. 

 

Use safety chain when fixes this fixture. Don’t handle the fixture by taking its head only, 

but always by taking its base. 

 

Maximum ambient temperature is Ta : 40

. Don’t operate it where the temperature is 

higher than this. 

 

In the event of serious operating problem, stop using the fixture immediately. Never try 

to  repair  the  fixture  by  yourself.  Repairs  carried  out  by  unskilled  people  can  lead  to 

damage  or  malfunction.  Please  contact  the  nearest  authorized  technical  assistance 

center. Always use the same type spare parts. 

 

Do not connect the device to any dimmer pack. 

 

Do not touch any wire during operation and there might be a hazard of electric shock. 

 

To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain 

or moisture. 

 

The housing must be replaced if they are visibly damaged. 

 

Do not look directly at the LED light beam while the fixture is on. 

 

Warning 

 

 

 

Please read the instructions carefully which includes important 

information about the installation, operation and maintenance. 

For  power  supply,  do  not  connect  in  series  much  more  than  31  units,  use 

another mains supply for next 31 units.

 

 

3A 

 

To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or 

moisture. 

 

Do not open the unit within five minutes after switching off. 

 

The  housing,  the  lenses,  or  the  ultraviolet  filter  must  be  replaced  if  they  are  visibly 

damaged. 

 

Caution 

There are no user serviceable parts inside the fixture. Do not open the housing or attempt 

any repairs yourself. In the unlikely situation, your unit may require service, please contact 

your nearest dealer. 

 

 

2. Technical Specifications   

 

 

LED

: total 212pcs, Red 70pcs, Green 71pcs, Blue 71pcs 

 

Power supply

 

Input Voltage: AC 100V-240V~50/60Hz 

Power consumption: 20W 

 

Beam Angle:

 15° 

 

Fuse: 

T 6.3A 

 

Dimension: 

272 x 67 x 252 mm

 

 

Weight: 

1.8kgs

 

 

 

  3. Installation   

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is 

firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure 

to which you are attaching the unit is secure and is able to support a weight of 10 times of 

the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the 

unit when installing the fixture.   

The equipment must be fixed by professionals. And it must be fixed at a place where is out 

of the touch of people and has no one pass by or under it. 

 

Summary of Contents for LED-212RGB

Page 1: ...lease read the instructions carefully before use 1A TABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 Installation 4 How to set the unit 5 How to control the fixture 6 DMX512 Configuration 7 DMX512 Connections 8 Troubleshooting 9 Fixture Cleaning ...

Page 2: ... directly at the LED light beam while the fixture is on Warning Please read the instructions carefully which includes important information about the installation operation and maintenance For power supply do not connect in series much more than 31 units use another mains supply for next 31 units 3A To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moistur...

Page 3: ...ction 12DMX output For DMX512 link use 3 5 pin XLR plug cable to link the next unit 5A 13DMX input For DMX512 link use 3 5 pin XLR plug cable to input DMX signal 14Mains input Connect to supply mains power 15Mains output Connect to supply mains power for the next unit 4 2 Main Function To select any of the given functions press the MENU button up to the required one is shown on the display Select ...

Page 4: ...ode Press the MENU button up to when the is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the auto show or show 1 or show 2 or show 12 Once the show has been selected press the ENTER button to confirm if you select show 1 or show 2 or show 12 you can press DOWN and UP button to select slowest or fastest press ENTER button to store or automat...

Page 5: ... shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the no blackout or yes blackout mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button 9A again Led Display Press the MENU button up...

Page 6: ...t s DMX input cable will have nothing connect it and the other fixtures will be set in slave mode automatically Their DMX input cables connect the last fixture DMX output cable daisy chain Any fixture can act as a Master or as a Slave C Easy Controller by CA 8 The easy remote control is used only in master slave mode There is a terminator for connect the easy controller inside the fixture By conne...

Page 7: ...gestions for easy troubleshooting 13A A The fixture does not work no light 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have ...

Page 8: ...ration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 199601 2 EN55103 2 1996 EN61000 3 2 2000 A2 2005 EN61000 3 3 1995 A1 2001 A2 2005 Harmonized Standard EN 60598 1 2004 IEC 60598 1 2003 corrigendum 2004 Part 1 General ...

Page 9: ...16A Innovation Quality Performance ...

Reviews: