- 45 -
R-Prism1/2 Reset Error
Focus Reset Error
Led Temp. Error
Check whether the temperature detecting board is normal.
Check whether the components of the temperature detecting board
are damaged.
Check whether the lead on the temperature detecting board is
installed in place or disconnected.
Check whether the position of the prism 1/2 where the magnet is
installed falls off or is damaged.
Check whether there are obstacles in the prism 1/2 operating range.
Check whether the Hall element on the prism 1/2 is damaged.
Check whether the lead connecting the Hall element on the prism 1/2
and the PCB board is in poor contact or disconnected.
Check whether the motor on the prism 1/2 is damaged.
Check whether the related circuit of the motor drive board on the
prism 1/2 is damage.
Check whether the position of the focus where the magnet is
installed falls off or is damaged.
Check whether there are obstacles in the focus operating range.
Check whether the Hall element on the focus is damaged.
Check whether the lead connecting the Hall element on the focus and
the PCB board is in poor contact or disconnected.
Check whether the motor on the focus is damaged.
Check whether the related circuit of the motor drive board on the
focus is damage.