background image

 

11A 

4.3 DMX Controller   

 

Use universal DMX controller to control the units, you have to set DMX address from 1 to 

512 channel so that the units can receive DMX signal. 

Press the MENU button up to when the 

  is showing on the display. Pressing ENTER 

button and the display will blink. Use DOWN and UP button to change the DMX512 address. 

Once the address has been selected, press and keep ENTER button pressed up to when 

the display stops blinking or storing automatically one minute later. To go back to the 

functions without any change press the MENU button again. If you use please refer to the 

following diagram to address your DMX512 channel for the first 4 units.   

 

3 channels

   

 

5. DMX512 Configuration   

 

 

4A 

y

  Do not allow children to operate the fixture. 

y

  Do not touch any wire during operation as there might be a hazard of electric shock. 

y

  Avoid power wires together around other cables. 

y

  Disconnect mains power before fuse/lamp replacement or servicing. 

y

  Replace fuse only with the same type. 

y

  In the event of serious operating problem, stop using the unit immediately.   

y

  Never turn on and off the unit time after time. 

y

  The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly 

damaged. 

y

  Do not open the unit as there are no user serviceable parts inside. 

y

  Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead 

to damage or malfunction. Please contact the nearest authorized technical assistance 

center.  

y

  Disconnect the mains power if the fixture is not used for a long time. 

y

  Do use original packing materials once transport it again. 

y

  Do not look directly at the LED light beam while the fixture is on. 

 

 

 

 

 

 

2.  Technical Specifications  

 

y

  Voltage

AC 100-240V~ 50/60Hz 

y

  LED: 1X50W LED 

y

  Fuse: T 6.3A 

y

  Power consumption

80 W 

y

  Dimension

  279 x226 x 191 mm   

y

  Weight

4 kg/pcs 

 

 

 

 

For power supply, do not connect in series much more than 7 units, use another 

mains supply for next 7 units. 

Summary of Contents for DELUGE LED-WAV-50W

Page 1: ...Innovation Quality Performance DELUGE LED WAV 50W User Manual Please read the instructions carefully before use ...

Page 2: ...e greater accumulation of dirt on the fixture s optics y Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days ...

Page 3: ...MX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some fixtures don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the fixture Set the proper address D No response to the sound 1 Make sure the fixture does not re...

Page 4: ... flammable materials close to the unit while operating as it is fire hazard y Look over power wires carefully replace immediately if there is any damage y Never run on for a long time lest shortening lifespan y Avoid any inflammable liquids water or metal objects entering the unit Once it happen cut off the mains power immediately y Do not operate in dirty and dusty environment also cleaning fixtu...

Page 5: ...d other cables y Disconnect mains power before fuse lamp replacement or servicing y Replace fuse only with the same type y In the event of serious operating problem stop using the unit immediately y Never turn on and off the unit time after time y The housing the lenses or the ultraviolet filter must be replaced if they are visibly damaged y Do not open the unit as there are no user serviceable pa...

Page 6: ...ceive DMX signal or run the built in programs 4 1 Master Slave Built In Preprogrammed Function The fixture will allow you to link 2 fixtures together and operate without a controller In Master Slave mode the first fixture whose DMX input jack has with nothing connect need to set as master and the other unit need to set as slave 1 via menu then the first unit will control the other to give an autom...

Page 7: ...et all channels Press the MENU button up to when the is shown on the display press ENTER button to setup Back to the functions without any change press MENU button 6A 4 Only for remote control Connecting with CA 8 UC3 to control the unit for Stand by Function and Mode function 5 DMX output For DMX512 link use 3 pin XLR plug cable to link the next unit 6 DMX input For DMX512 link use 3 5 pin XLR pl...

Page 8: ...on up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the set the fixture as master or set the fixture as slave Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after one minute To go back to the functions without any change press the MENU button a...

Reviews: