background image

 

3A 

1. Safety  Introductions   

 

 

WARNING   

 

y

  Please keep this User Guide for future consultation. If you sell the unit to another user, 

be sure that they also receive this instruction booklet. 

y

  All fixtures are intact from the manufacturer, please operate follow up the user manual, 

artificial fault are not under guarantee repair. 

y

  Unpack and check carefully that there is no transportation damage before using the 

unit. 

y

  The unit is for indoor use only. Use only in a dry location. 

y

  Do install and operate by operator. 

y

  Use safety chain when fixes the unit. Don’t handle the unit by taking its head only, but 

always by taking its base. 

y

  The unit must be installed in a location with adequate ventilation, at least 50cm from 

adjacent surfaces.   

y

  Be sure that no ventilation slots are blocked, otherwise the unit will be overheated. 

y

  Before operating, ensure that the voltage and frequency of power supply match the 

power requirements of the unit. 

y

  It’s important to ground the yellow/green conductor to earth in order to avoid electric 

shock. 

y

  Maximum ambient temperature TA : 40

. Don’t operate it where the temperature is 

higher than this. 

y

  Don’t connect the device to any dimmer pack. 

y

  First run, there will be smoke or smells, and all disappearing a few minutes later. 

y

  Make sure there are no flammable materials close to the unit while operating, as it is 

fire hazard. 

y

  Look over power wires carefully, replace immediately if there is any damage. 

y

  Never run on for a long time lest shortening lifespan. 

y

  Avoid any inflammable liquids, water or metal objects entering the unit. Once it happen, 

cut off the mains power immediately. 

y

  Do not operate in dirty and dusty environment, also cleaning fixtures regularly. 

Please read the instructions carefully which includes important 

information about the installation, operation and maintenance. 

 

12A 

 

 

  6. DMX512 Connections   

The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels. 

 

 

1.  Connect the fixture together in a “daisy chain” by XLR plug cable from the output of the 

fixture to the input of the next fixture. The cable cannot be branched or split to a “Y” 

cable. Inadequate or damaged cables, soldered joints or corroded connectors can 

easily distort the signal and shut down the system 

2.  The DMX output and input connectors are pass-through to maintain the DMX circuit 

when one of the units’ power is disconnected. 

3.  At last fixture, the DMX cable has to be terminated with a terminator to reduce signal 

errors. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 

3-pin XLR-plug and plug it in the DMX-output of the last fixture. 

4.  Each lighting fixture needs to have an address set to receive the data sent by the 

controller. The address number is between 1-512    (usually 0 & 1 are equal to 1). 

Summary of Contents for DELUGE LED-WAV-50W

Page 1: ...Innovation Quality Performance DELUGE LED WAV 50W User Manual Please read the instructions carefully before use ...

Page 2: ...e greater accumulation of dirt on the fixture s optics y Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days ...

Page 3: ...MX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some fixtures don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the fixture Set the proper address D No response to the sound 1 Make sure the fixture does not re...

Page 4: ... flammable materials close to the unit while operating as it is fire hazard y Look over power wires carefully replace immediately if there is any damage y Never run on for a long time lest shortening lifespan y Avoid any inflammable liquids water or metal objects entering the unit Once it happen cut off the mains power immediately y Do not operate in dirty and dusty environment also cleaning fixtu...

Page 5: ...d other cables y Disconnect mains power before fuse lamp replacement or servicing y Replace fuse only with the same type y In the event of serious operating problem stop using the unit immediately y Never turn on and off the unit time after time y The housing the lenses or the ultraviolet filter must be replaced if they are visibly damaged y Do not open the unit as there are no user serviceable pa...

Page 6: ...ceive DMX signal or run the built in programs 4 1 Master Slave Built In Preprogrammed Function The fixture will allow you to link 2 fixtures together and operate without a controller In Master Slave mode the first fixture whose DMX input jack has with nothing connect need to set as master and the other unit need to set as slave 1 via menu then the first unit will control the other to give an autom...

Page 7: ...et all channels Press the MENU button up to when the is shown on the display press ENTER button to setup Back to the functions without any change press MENU button 6A 4 Only for remote control Connecting with CA 8 UC3 to control the unit for Stand by Function and Mode function 5 DMX output For DMX512 link use 3 pin XLR plug cable to link the next unit 6 DMX input For DMX512 link use 3 5 pin XLR pl...

Page 8: ...on up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the set the fixture as master or set the fixture as slave Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after one minute To go back to the functions without any change press the MENU button a...

Reviews: