15- 

A. The fixture does not work, no light 

1.  Check the connection of power and main fuse. 

2.  Measure the mains voltage on the main connector. 

B. Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.  If the DMX LED is on and no response to the channel, check the address settings and           

DMX polarity. 

3.  If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

of the fixture or the previous one. 

4.  Try to use another DMX controller.     

5.  Check if the DMX cables run near or run alongside to high voltage cables that may 

cause damage or interference to DMX interface circuit.   

C. Some fixtures don’t respond to the easy controller   

1.  You may have a break in the DMX cabling. Check the LED for the response of the 

master/ slave mode signal. 

2.  Wrong DMX address in the fixture. Set the proper address. 

D. No response to the sound 

1.  Make sure the fixture does not receive DMX signal. 

2.  Check microphone to see if it is good by tapping the microphone. 

E. One of the channels is not working well 

1.  The stepper motor might be damaged or the cable connected to the PCB is broken. 

2.  The motor’s drive IC on the PCB might be out of condition. 

 

 

 8. Fixture Cleaning  

The cleaning of internal must be carried out periodically to optimize light output. Cleaning 

frequency depends on the environment in which the fixture operates: damp, smoky or 

particularly dirty surrounding can cause greater accumulation of dirt on the fixture’s optics. 

y

  Clean with soft cloth using normal glass cleaning fluid. 

y

  Always dry the parts carefully. 

y

  Clean the external optics at least every 20 days. Clean the internal optics at least every 

30/60 days. 

 

 

 

4- 

y

  Do not allow children to operate the fixture. 

y

  Do not touch any wire during operation as there might be a hazard of electric shock. 

y

  Avoid power wires together arounding other cables. 

y

  Disconnect mains power before fuse/lamp replacement or servicing. 

y

  Replace fuse only with the same type. 

y

  In the event of serious operating problem, stop using the unit immediately.   

y

  Never turn on and off the unit time after time. 

y

  The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly 

damaged. 

y

  Do not open the unit as there are no user serviceable parts inside. 

y

  Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead 

to damage or malfunction. Please contact the nearest authorized technical assistance 

center.  

y

  Disconnect the mains power if the fixture is not used for a long time. 

y

  Do use original packing materials once transport it again. 

y

  Do not look directly at the LED light beam while the fixture is on. 

 

 

 

 

 

Installation  

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit 

is firmly fixed to avoid vibration and slipping while operating. Always ensure that the 

structure to which you are attaching the unit is secure and is able to support a weight of 10 

times of the unit’s weight. Also always use a safety cable that can hold 12 times of the 

weight of the unit when installing the fixture.   

The equipment must be fixed by professionals. And it must be fixed at a place where is out 

of the touch of people and has no one pass by or under it. 

 

 

 

 

 

For power supply, do not connect in series much more than 7 units, use another 

mains supply for next 7 units.

 

Summary of Contents for CP-21TC

Page 1: ...Innovation Quality Performance PRO COLOR PAR 21TC CP 21TC User Manual Please read the instructions carefully before use...

Page 2: ...1...

Page 3: ...ABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 How To Set The Fixture 4 How To Control The Fixture 5 DMX 512 Configuration 6 DMX 512 Connections 7 Troubleshooting 8 Fixture Cleani...

Page 4: ...e TA 40 Don t operate it where the temperature is higher than this y Don t connect the device to any dimmer pack y First run there will be smoke or smells and all disappearing a few minutes later y Ma...

Page 5: ...s carefully y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 4 y Do not allow children to operate the fixture y Do not touch any wire during opera...

Page 6: ...not be branched or split to a Y cable Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 2 The DMX output and input connectors a...

Page 7: ...ns power for the next unit 9 Mains input Connect to mains AC 10 Safety Ring Keep the installation safe 3 2 Main Function To select any functions press MENU button until the required one is shown on th...

Page 8: ...button to change the DMX 512 address 12 the display stops blinking or storing automatically one minute later To go back to the functions without any change press the MENU button again If you use plea...

Page 9: ...LED fast blinking 8 Once the address has been selected press ENTER button to setup or automatically exit menu mode without any change after one minute Back to the previous functions without any change...

Page 10: ...s the MENU button up to when the is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select display 10 always on or display off 20 seconds after exit men...

Reviews: