9- 

ENTER

 button to store and g 255 will blink on the display, press 

UP

 and 

Down

 button to 

adjust the value, press 

ENTER

 button to store and b 255 will blink on the display, press 

UP

 

and 

Down

 button to adjust the value, and press 

ENTER

 button to store. Back to the main 

functions without any change please press the

 MENU 

button. 

Fan Speed 

Press  the 

MENU

  button  up  to  when  the  Fan  Speed  is  showing  on  the  display.  Pressing 

ENTER

 button and the display will blink. Use 

DOWN 

and 

UP

 button to select  Auto Speed 

(When the temperature of the unit under 40 , FAN stops; between 45 ~55 , FAN runs at 

ć

ć

ć

half  speed;  above  60 ,  FAN  runs  at  full  speed.  The  LEDs  will  be  off  if  the  temperature 

ć

higher than 75

ć

) or High Speed, press ENTER button to store. To go back to the functions 

press the

 MENU

 button. 

Fixture Temp 

Press the 

MENU

 button up to when the  Fixture Temp is blinking on the display. Pressing 

ENTER

  button  and  the  display  will  show  the  temperature  of  the  unit.  To  go  back  to  the 

functions press the

 MENU

 button. 

Fixture Time 

Press  the 

MENU

  button  up  to  when  the  Fixture  Time  is  blinking  on  the  display.  Pressing 

ENTER

 button and the display will show the number of working hours of the unit. To go back 

to the functions press the

 MENU

 button. 

Firmware Version 

Press  the 

MENU

  button  up  to  when  the  Firmware  Version  is  blinking  on  the  display. 

Pressing 

ENTER

 button and the display will show the version of software of the unit. To go 

back to the functions press the

 MENU

 button. 

 
 

  4. How To Control The Unit   

You can operate the unit in three ways: 

1.  By master/slave built-in preprogram function 
2.  By easy controller 
3.  By universal DMX controller 
4.  By Rc8ch controller 

 

4.1 Master/Slave Built In Preprogrammed Function   

By  linking the  units in master/slave connection, the first  unit  will control the other units  to 
give an automatic, sound activated, synchronized light show. This function is good when you 
want an instant show.   

 

10-

2-light show 

In slave mode, slave 1 means the unit run as the master unit and slave 2 means 2-light show. 

In order to create a great light show, you can set slave 2 on the second unit to get contrast 

movement to each other, even if you have two units only. 

 

4.2 Easy Controller   

The easy remote control is used only in master/slave mode. By connecting 

to the 1/4” microphone jack of the first unit, you will find that the remote 

controller on the first unit will control all the other units for Stand by, Function 

and Mode selection. 

 

4.3 DMX Controller   

Using universal DMX controller to control the units, you have to set DMX address from 1 to 

512 channel so that the units can receive DMX signal. 

Press  the 

MENU

  button  up  to  when  the 

DMX  Address

  is  showing  on  the  display.  Press 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 

address. Once the address has been selected, press and keep 

ENTER

 button to store. To 

go back to the functions without any change press the

 MENU

 button or wait for 8 seconds to 

exit menu mode. 

Please refer to the following diagram to address your DMX512 channel for the first 4 units: 

Channel Mode

Unit 1 

Unit 2 

Unit 3 

Unit 4 

3 channels 

12 

6 channels1 

13 

19 

6 channels2 

13 

19 

9 channels 

10 

19 

28 

12 channels 

13 

25 

37 

15channels 

16 

31 

46 

Stand By 

Blackout the unit 

Function 

1. Sync. Strobe 

2. Async strobe 

3. Sound Strobe 

Select 

Manua Color

or color 1-32

Select 

show 1-8   

or Auto fade 

Select Speed 

1. Fast 

2. Middle 

3. Slow 

Mode 

Sound (LED OFF) 

LED On 

Slow blinking 

Fast blinking 

Summary of Contents for CB-348TC

Page 1: ...on of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonize...

Page 2: ...xture Cleaning 18 6 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the env...

Page 3: ...user be sure that they also receive this instruction booklet y Unpack and check carefully there is no transportation damage before using the unit y Before operating ensure that the voltage and freque...

Page 4: ...sion 965 x 167 x 152 mm y Weight 7 2kgs 16 4 6 RC8ch Controller Address setting Each time you make a different connection you have to reset the address There are two ways that you can set address for...

Page 5: ...1 usually 0 1 are equal to 1 6 The end of the DMX 512 system should be terminated to reduce signal errors 7 3 pin XLR connectors are more popular than 5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative sign...

Page 6: ...cted Press ENTER button to store Back to the main functions without any change press the MENU button or wait for 8 seconds Hold MENU button to quit menu mode the unit will run the built in program you...

Page 7: ...13 6...

Page 8: ...then you can press DOWN and UP button to select Speed 1 slow speed or Speed 2 middle speed or Speed 3 fast speed press ENTER button to store the unit will run in the speed that selected Back to the m...

Page 9: ...conds to exit menu mode Back Light Press the MENU button up to when the Back Light is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the on ba...

Page 10: ...Rc8ch controller 4 1 Master Slave Built In Preprogrammed Function By linking the units in master slave connection the first unit will control the other units to give an automatic sound activated sync...

Reviews: